Volumn 39, Issue 8, 2012, Pages 4807-4811

An evaluation of interference of inflatable penile prostheses with electromagnetic localization and tracking system

Author keywords

Calypso; interference; metal; penile prostheses

Indexed keywords

FUNCTION EVALUATION; METALS; PHANTOMS; QUALITY ASSURANCE; TRACKING (POSITION); TRANSPONDERS; WAVE INTERFERENCE;

EID: 84864719178     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4736976     Document Type: Article
Times cited : (6)

References (17)
  • 2
    • 33847328730 scopus 로고    scopus 로고
    • Multi-institutional clinical experience with the calypso system in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy
    • 10.1016/j.ijrob2006.10.026
    • P. Kupelian, Multi-institutional clinical experience with the calypso system in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy., Int. J. Radiat. Oncol. Biol. Phys. 67, 1088-1098 (2007). 10.1016/j.ijrobp.2006.10.026
    • (2007) Int. J. Radiat. Oncol. Biol. Phys. , vol.67 , pp. 1088-1098
    • Kupelian, P.1
  • 3
    • 49549105127 scopus 로고    scopus 로고
    • The effect of transponder motion on the accuracy of the calypso electromagnetic localization system
    • 10.1016/j.ijrob2008.05.036
    • M. J. Murphy, R. Eidens, E. Vertatschitsch, and J. N. Wright, The effect of transponder motion on the accuracy of the calypso electromagnetic localization system., Int. J. Radiat. Oncol. Biol. Phys. 72, 295-299 (2008). 10.1016/j.ijrobp.2008.05.036
    • (2008) Int. J. Radiat. Oncol. Biol. Phys. , vol.72 , pp. 295-299
    • Murphy, M.J.1    Eidens, R.2    Vertatschitsch, E.3    Wright, J.N.4
  • 4
    • 33646487136 scopus 로고    scopus 로고
    • Target localization and real-time tracking using the calypso 4d localization system in patients with localized prostate cancer
    • 10.1016/j.ijrob2006.01.050
    • T. R. Willoughby, Target localization and real-time tracking using the calypso 4d localization system in patients with localized prostate cancer., Int. J. Radiat. Oncol. Biol. Phys. 65, 528-534 (2006). 10.1016/j.ijrobp.2006.01.050
    • (2006) Int. J. Radiat. Oncol. Biol. Phys. , vol.65 , pp. 528-534
    • Willoughby, T.R.1
  • 5
    • 69249097924 scopus 로고    scopus 로고
    • Prostate tumor alignment and continuous, real-time adaptive radiation therapy using electromagnetic fiducials: Clinical and cost-utility analyses
    • 10.1016/j.urolonc.2008.04.017
    • M. M. Quigley, T. P. Mate, and J. E. Sylvester, Prostate tumor alignment and continuous, real-time adaptive radiation therapy using electromagnetic fiducials: Clinical and cost-utility analyses., Urol. Oncol. 27, 473-482 (2009). 10.1016/j.urolonc.2008.04.017
    • (2009) Urol. Oncol. , vol.27 , pp. 473-482
    • Quigley, M.M.1    Mate, T.P.2    Sylvester, J.E.3
  • 6
    • 85027218457 scopus 로고    scopus 로고
    • (Calypso Medical Technologies, Inc., Seattle, WA)
    • Calypso System Users Manual (Calypso Medical Technologies, Inc., Seattle, WA, 2010), pp. 1-5.
    • (2010) Calypso System Users Manual , pp. 1-5
  • 7
    • 79959561621 scopus 로고    scopus 로고
    • Investigations of interference between electromagnetic transponders and wireless mosfet dosimeters: A phantom study
    • 10.1118/1.3578602
    • Z. Su, L. Zhang, V. Ramakrishnan, M. Hagan, and M. Anscher, Investigations of interference between electromagnetic transponders and wireless mosfet dosimeters: A phantom study., Med. Phys. 38, 2450-2454 (2011). 10.1118/1.3578602
    • (2011) Med. Phys. , vol.38 , pp. 2450-2454
    • Su, Z.1    Zhang, L.2    Ramakrishnan, V.3    Hagan, M.4    Anscher, M.5
  • 8
    • 20444506383 scopus 로고    scopus 로고
    • A survey of patients with inflatable penile prostheses for satisfaction
    • DOI 10.1097/01.ju.0000161608.21337.8d
    • M. J. Brinkman, G. D. Henry, S. K. Wilson, J. R. Delk 2nd, G. A. Denny, M. Young, and M. A. Cleves, A survey of patients with inflatable penile prostheses for satisfaction., J. Urol. 174, 253-257 (2005). 10.1097/01.ju. 0000161608.21337.8d (Pubitemid 40825728)
    • (2005) Journal of Urology , vol.174 , Issue.1 , pp. 253-257
    • Brinkman, M.J.1    Henry, G.D.2    Wilson, S.K.3    Delk II, J.R.4    Denny, G.A.5    Young, M.6    Cleves, M.A.7
  • 9
    • 0023920642 scopus 로고
    • Implantation of model ams 700 penile prosthesis: Long-term results
    • W. L. Furlow, B. Goldwasser, and J. C. Gundian, Implantation of model ams 700 penile prosthesis: Long-term results., J. Urol. 139, 741-742 (1988).
    • (1988) J. Urol. , vol.139 , pp. 741-742
    • Furlow, W.L.1    Goldwasser, B.2    Gundian, J.C.3
  • 10
    • 0024075512 scopus 로고
    • Ams 700 inflatable penile prosthesis
    • 10.1016/0090-4295(88)90405-0
    • D. C. Merrill, Ams 700 inflatable penile prosthesis., Urology 32, 283 (1988). 10.1016/0090-4295(88)90405-0
    • (1988) Urology , vol.32 , pp. 283
    • Merrill, D.C.1
  • 12
    • 0028389257 scopus 로고
    • Ex vivo evaluation of ferromagnetism and artifacts of cardiac occluders exposed to a 1.5-t mr system
    • 10.1002/jmri.1880040220
    • F. G. Shellock and S. M. Morisoli, Ex vivo evaluation of ferromagnetism and artifacts of cardiac occluders exposed to a 1.5-t mr system., J. Magn. Reson. Imaging 4, 213-215 (1994). 10.1002/jmri.1880040220
    • (1994) J. Magn. Reson. Imaging , vol.4 , pp. 213-215
    • Shellock, F.G.1    Morisoli, S.M.2
  • 15
    • 0036680186 scopus 로고    scopus 로고
    • Implementation and utility of a daily ultrasound-based localization system with intensity-modulated radiotherapy for prostate cancer
    • DOI 10.1016/S0360-3016(02)02820-1, PII S0360301602028201
    • J. Morr, T. DiPetrillo, J. S. Tsai, M. Engler, and D. E. Wazer, Implementation and utility of a daily ultrasound-based localization system with intensity-modulated radiotherapy for prostate cancer., Int. J. Radiat. Oncol. Biol. Phys. 53, 1124-1129 (2002). 10.1016/S0360-3016(02)02820-1 (Pubitemid 34787846)
    • (2002) International Journal of Radiation Oncology Biology Physics , vol.53 , Issue.5 , pp. 1124-1129
    • Morr, J.1    DiPetrillo, T.2    Tsai, J.-S.3    Engler, M.4    Wazer, D.E.5
  • 16
    • 0036680467 scopus 로고    scopus 로고
    • Initial experience with ultrasound localization for positioning prostate cancer patients for external beam radiotherapy
    • DOI 10.1016/S0360-3016(02)02826-2, PII S0360301602028262
    • C. F. Serago, S. J. Chungbin, S. J. Buskirk, G. A. Ezzell, A. C. Collie, and S. A. Vora, Initial experience with ultrasound localization for positioning prostate cancer patients for external beam radiotherapy., Int. J. Radiat. Oncol. Biol. Phys. 53, 1130-1138 (2002). 10.1016/S0360-3016(02)02826-2 (Pubitemid 34787847)
    • (2002) International Journal of Radiation Oncology Biology Physics , vol.53 , Issue.5 , pp. 1130-1138
    • Serago, C.F.1    Chungbin, S.J.2    Buskirk, S.J.3    Ezzell, G.A.4    Collie A.Craig5    Vora, S.A.6
  • 17
    • 85027224560 scopus 로고    scopus 로고
    • Millennium Research Group, US markets for urological devices (rpus31ur08), 2008
    • Millennium Research Group, US markets for urological devices (rpus31ur08), 2008.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.