메뉴 건너뛰기




Volumn 38, Issue 5, 2011, Pages 2450-2454

Investigations of interference between electromagnetic transponders and wireless MOSFET dosimeters: A phantom study

Author keywords

adaptive radiotherapy; electromagnetic transponder; in vivo dosimetry; interference; localization accuracy; target motion; wireless MOSFET dosimeter

Indexed keywords

BIOMEDICAL ENGINEERING; DOSIMETERS; FAULT TOLERANT COMPUTER SYSTEMS; METALS; MOS DEVICES; MULTIVARIANT ANALYSIS; NATURAL LANGUAGE PROCESSING SYSTEMS; OXIDE SEMICONDUCTORS; PHANTOMS; RADIOTHERAPY; TRANSPONDERS; WAVE INTERFERENCE;

EID: 79959561621     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3578602     Document Type: Article
Times cited : (3)

References (11)
  • 1
    • 23844553577 scopus 로고    scopus 로고
    • A review of prostate motion with considerations for the treatment of prostate cancer
    • DOI 10.1016/j.meddos.2005.03.005, PII S0958394705001007
    • T. Byrne, A review of prostate motion with considerations for the treatment of prostate cancer., Med. Dosim. 30 (3), 155-161 (2005). 10.1016/j.meddos.2005.03.005 (Pubitemid 41160455)
    • (2005) Medical Dosimetry , vol.30 , Issue.3 , pp. 155-161
    • Byrne, T.E.1
  • 4
    • 33645368752 scopus 로고    scopus 로고
    • Influence of intrafraction motion on margins for prostate radiotherapy
    • 10.1016/j.ijrob2005.12.033
    • D. W. Litzenberg, Influence of intrafraction motion on margins for prostate radiotherapy., Int. J. Radiat. Oncol., Biol. Phys. 65 (2), 548-553 (2006). 10.1016/j.ijrobp.2005.12.033
    • (2006) Int. J. Radiat. Oncol., Biol. Phys. , vol.65 , Issue.2 , pp. 548-553
    • Litzenberg, D.W.1
  • 6
    • 28044450858 scopus 로고    scopus 로고
    • Evaluation of precalibrated implantable MOSFET radiation dosimeters for megavoltage photon beams
    • DOI 10.1118/1.2065447
    • T. M. Briere, A. S. Beddar, and M. T. Gillin, Evaluation of precalibrated implantable MOSFET radiation dosimeters for megavoltage photon beams., Med. Phys. 32 (11), 3346-3349 (2005). 10.1118/1.2065447 (Pubitemid 41689285)
    • (2005) Medical Physics , vol.32 , Issue.11 , pp. 3346-3349
    • Briere, T.M.1    Beddar, A.S.2    Gillin, M.T.3
  • 7
    • 36649005134 scopus 로고    scopus 로고
    • Implantable MOSFET detectors: Evaluation of a new design
    • DOI 10.1118/1.2799578
    • T. M. Briere, M. T. Gillin, and A. S. Beddar, Implantable MOSFET detectors: Evaluation of a new design., Med. Phys. 34 (12), 4585-4590 (2007). 10.1118/1.2799578 (Pubitemid 350197696)
    • (2007) Medical Physics , vol.34 , Issue.12 , pp. 4585-4590
    • Briere, T.M.1    Gillin, M.T.2    Beddar, A.S.3
  • 10
    • 51449091243 scopus 로고    scopus 로고
    • The observed variance between predicted and measured radiation dose in breast and prostate patients utilizing an in vivo dosimeter
    • 10.1016/j.ijrob2008.05.058
    • C. W. Scarantino, The observed variance between predicted and measured radiation dose in breast and prostate patients utilizing an in vivo dosimeter., Int. J. Radiat. Oncol., Biol. Phys. 72 (2), 597-604 (2008). 10.1016/j.ijrobp. 2008.05.058
    • (2008) Int. J. Radiat. Oncol., Biol. Phys. , vol.72 , Issue.2 , pp. 597-604
    • Scarantino, C.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.