Volumn 39, Issue 8, 2012, Pages 4775-4787

On the property of measurements with the PTW microLion chamber in continuous beams

Author keywords

ambient electric field; continuous beam; general recombination; isooctane; liquid ionization chamber; perturbation; radiation dosimetry; tetramethylsilane; two dose rate method

Indexed keywords

DOSIMETRY; ELECTRIC FIELDS; ELECTRIC LOSSES; IONIZATION CHAMBERS; LIQUIDS; MONTE CARLO METHODS; PARAFFINS; PHOTOIONIZATION; PHOTONS; POLYOLS; SILANES;

EID: 84864685920     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4736804     Document Type: Article
Times cited : (12)

References (22)
  • 1
    • 0242606138 scopus 로고    scopus 로고
    • First tests of a liquid ionization chamber to monitor intensity modulated radiation beams
    • DOI 10.1088/0031-9155/48/21/007, PII S0031915503626734
    • K. Eberle, J. Engler, G. Hartmann, R. Hofmann, and J. R. Hörandel, First tests of a liquid ionization chamber to monitor intensity modulated radiation beams., Phys. Med. Biol. 48, 3555-3564 (2003). 10.1088/0031-9155/48/ 21/007 (Pubitemid 37427953)
    • (2003) Physics in Medicine and Biology , vol.48 , Issue.21 , pp. 3555-3564
    • Eberle, K.1    Engler, J.2    Hartmann, G.3    Hofmann, R.4    Horandel, J.R.5
  • 3
    • 34249072857 scopus 로고    scopus 로고
    • Development of a guarded liquid ionization chamber for clinical dosimetry
    • DOI 10.1088/0031-9155/52/11/011, PII S0031915507390180, 011
    • K. J. Stewart, A. Elliot, and J. P. Seuntjens, Development of a guarded liquid ionization chamber for clinical dosimetry., Phys. Med. Biol. 52, 3089-3104 (2007). 10.1088/0031-9155/52/11/011 (Pubitemid 46795249)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.11 , pp. 3089-3104
    • Stewart, K.J.1    Elliott, A.2    Seuntjens, J.P.3
  • 5
    • 2642710922 scopus 로고    scopus 로고
    • Liquid ionization chamber measurements of dose distributions in small 6 MV photon beams
    • DOI 10.1088/0031-9155/43/1/002, PII S0031915598852640
    • A. Daşu, P. O. Löfroth, and G. Wickman, Liquid ionization chamber measurements of dose distributions in small 6 MV photon beams., Phys. Med. Biol. 43, 21-36 (1998). 10.1088/0031-9155/43/1/002 (Pubitemid 28103708)
    • (1998) Physics in Medicine and Biology , vol.43 , Issue.1 , pp. 21-36
    • Dasu, A.1    Lofroth, P.-O.2    Wickman, G.3
  • 6
    • 0032873493 scopus 로고    scopus 로고
    • 192Ir line source using a liquid ionization chamber
    • DOI 10.1118/1.598698
    • J. Bahar-Gogani, G. Wickman, L. Johansson, and B. E. Johansson, Assessment of the relative dose distribution around an 192Ir line source using a liquid ionization chamber., Med. Phys. 26, 1932-1942 (1999). 10.1118/1.598698 (Pubitemid 29442277)
    • (1999) Medical Physics , vol.26 , Issue.9 , pp. 1932-1942
    • Bahar-Gogani, J.1    Wickman, G.2    Johansson, L.3    Johansson, B.E.4
  • 7
    • 0034065594 scopus 로고    scopus 로고
    • Comparative dosimetry in narrow high-energy photon beams
    • DOI 10.1088/0031-9155/45/3/308, PII S0031915500086930
    • M. Westermark, J. Arndt, B. Nilsson, and A. Brahme, Comparative dosimetry in narrow high-energy photon beams., Phys. Med. Biol. 45, 685-702 (2000). 10.1088/0031-9155/45/3/308 (Pubitemid 30163657)
    • (2000) Physics in Medicine and Biology , vol.45 , Issue.3 , pp. 685-702
    • Westermark, M.1    Arndt, J.2    Nilsson, B.3    Brahme, A.4
  • 8
    • 21244477530 scopus 로고    scopus 로고
    • Assessment of correlated dose and sensitivity profiles on a multi-slice CT scanner
    • DOI 10.1093/rpd/nch500
    • J. Bahar-Gogani, P. Hägglund, and G. Wickman, Assessment of correlated dose and sensitivity profiles on a multi-slice CT scanner., Radiat. Prot. Dosim. 114, 332-336 (2005). 10.1093/rpd/nch500 (Pubitemid 40883705)
    • (2005) Radiation Protection Dosimetry , vol.114 , Issue.1-3 , pp. 332-336
    • Gogani, J.B.1    Hagglund, P.2    Wickman, G.3
  • 9
    • 84855439423 scopus 로고    scopus 로고
    • Dose homogeneity specification for reference dosimetry of nonstandard fields
    • 10.1118/1.3669487
    • E. Chung, E. Soisson, and J. Seuntjens, Dose homogeneity specification for reference dosimetry of nonstandard fields., Med. Phys. 39, 407-414 (2012). 10.1118/1.3669487
    • (2012) Med. Phys. , vol.39 , pp. 407-414
    • Chung, E.1    Soisson, E.2    Seuntjens, J.3
  • 10
    • 0031034634 scopus 로고    scopus 로고
    • General collection efficiency for liquid isooctane and tetramethylsilane used as sensitive media in a parallel-plate ionization chamber
    • DOI 10.1088/0031-9155/42/1/009, PII S0031915597725880
    • B. Johansson and G. Wickman, General collection efficiency for liquid isooctane and tetramethylsilane used as sensitive media in a parallel-plate ionization chamber., Phys. Med. Biol. 42, 133-145 (1997). 10.1088/0031-9155/42/ 1/009 (Pubitemid 27055958)
    • (1997) Physics in Medicine and Biology , vol.42 , Issue.1 , pp. 133-145
    • Johansson, B.1    Wickman, G.2
  • 11
    • 0030806146 scopus 로고    scopus 로고
    • General collection efficiency for liquid isooctane and tetramethylsilane in pulsed radiation
    • DOI 10.1088/0031-9155/42/10/006, PII S003191559780276X
    • B. Johansson, G. Wickman, and J. Bahar-Gogani, General collection efficiency for liquid isooctane and tetramethylsilane in pulsed radiation., Phys. Med. Biol. 42, 1929-1938 (1997). 10.1088/0031-9155/42/10/006 (Pubitemid 27448993)
    • (1997) Physics in Medicine and Biology , vol.42 , Issue.10 , pp. 1929-1938
    • Johansson, B.1    Wickman, G.2    Bahar-Gogani, J.3
  • 12
    • 70149094151 scopus 로고    scopus 로고
    • Determining charge collection efficiency in parallel-plate liquid ionization chambers
    • 10.1088/0031-9155/54/12/005
    • J. Pardo-Montero and F. Gómez, Determining charge collection efficiency in parallel-plate liquid ionization chambers., Phys. Med. Biol. 54, 3677-3689 (2009). 10.1088/0031-9155/54/12/005
    • (2009) Phys. Med. Biol. , vol.54 , pp. 3677-3689
    • Pardo-Montero, J.1    Gómez, F.2
  • 13
    • 78049426900 scopus 로고    scopus 로고
    • A two-dose-rate method for general recombination correction for liquid ionization chambers in pulsed beams
    • 10.1088/0031-9155/55/15/004
    • H. Tölli, R. Sjögren, and M. Wendelsten, A two-dose-rate method for general recombination correction for liquid ionization chambers in pulsed beams., Phys. Med. Biol. 55, 4247-4260 (2010). 10.1088/0031-9155/55/15/004
    • (2010) Phys. Med. Biol. , vol.55 , pp. 4247-4260
    • Tölli, H.1    Sjögren, R.2    Wendelsten, M.3
  • 14
    • 79551658811 scopus 로고    scopus 로고
    • Application of the two-dose-rate method for general recombination correction for liquid ionization chambers in continuous beams
    • 10.1088/0031-9155/56/2/001
    • J. Andersson and H. Tölli, Application of the two-dose-rate method for general recombination correction for liquid ionization chambers in continuous beams., Phys. Med. Biol. 56, 299-314 (2011). 10.1088/0031-9155/56/2/ 001
    • (2011) Phys. Med. Biol. , vol.56 , pp. 299-314
    • Andersson, J.1    Tölli, H.2
  • 15
    • 1842329396 scopus 로고
    • Saturation characteristics of parallel-plate ionization chambers
    • 10.1088/0031-9155/9/2/302
    • J. R. Greening, Saturation characteristics of parallel-plate ionization chambers., Phys. Med. Biol. 9, 143-154 (1964). 10.1088/0031-9155/9/2/302
    • (1964) Phys. Med. Biol. , vol.9 , pp. 143-154
    • Greening, J.R.1
  • 16
    • 0031859143 scopus 로고    scopus 로고
    • Liquid ionization chambers for absorbed dose measurements in water at low dose rates and intermediate photon energies
    • DOI 10.1118/1.598268
    • G. Wickman, B. Johansson, J. Bahar-Gogani, T. Holmström, and J. E. Grindborg, Liquid ionization chambers for absorbed dose measurements in water at low dose rates and intermediate photon energies., Med. Phys. 25, 900-907 (1998). 10.1118/1.598268 (Pubitemid 28285766)
    • (1998) Medical Physics , vol.25 , Issue.6 , pp. 900-907
    • Wickman, G.1    Johansson, B.2    Bahar-Gogani, J.3    Holmstrom, T.4    Grindborg, J.E.5
  • 18
    • 53749085696 scopus 로고    scopus 로고
    • A quantitative and comparative study of radionuclidic and chemical impurities in water samples irradiated in a niobium target with Havar vs. niobium-sputtered Havar as entrance foils
    • 10.1016/j.apradiso.2008.04.016
    • M. A. Avila-Rodriguez, J. S. Wilson, and S. A. McQuarrie, A quantitative and comparative study of radionuclidic and chemical impurities in water samples irradiated in a niobium target with Havar vs. niobium-sputtered Havar as entrance foils., Appl. Radiat. Isot. 66, 1775-1780 (2008). 10.1016/j.apradiso. 2008.04.016
    • (2008) Appl. Radiat. Isot. , vol.66 , pp. 1775-1780
    • Avila-Rodriguez, M.A.1    Wilson, J.S.2    McQuarrie, S.A.3
  • 21
    • 36149016302 scopus 로고
    • Initial recombination of ions
    • 10.1103/PhysRev.54.554
    • L. Onsager, Initial recombination of ions., Phys. Rev. 54, 554-557 (1938). 10.1103/PhysRev.54.554
    • (1938) Phys. Rev. , vol.54 , pp. 554-557
    • Onsager, L.1
  • 22
    • 84975270068 scopus 로고
    • Der elektrische strom in ioniserter luft in einem ebenen kondensator
    • G. Mie, Der elektrische strom in ioniserter luft in einem ebenen kondensator., Ann. Phys. (Leipzig) 13, 857-889 (1904).
    • (1904) Ann. Phys. (Leipzig) , vol.13 , pp. 857-889
    • Mie, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.