메뉴 건너뛰기




Volumn 22, Issue 9, 2012, Pages 1896-1903

Prevalence and prognosis of coronary stent gap detected by multi-detector CT: A follow-up study

Author keywords

Coronary angiography; Coronary restenosis; Prognosis; Stent; X ray computed tomography

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTICLE; CLINICAL FEATURE; CORONARY STENT; FEMALE; FOLLOW UP; HUMAN; IN-STENT RESTENOSIS; MAJOR CLINICAL STUDY; MALE; MORBIDITY; MULTIDETECTOR COMPUTED TOMOGRAPHY; PREVALENCE; PRIORITY JOURNAL; PROGNOSIS; PROSTHESIS FAILURE; STENT GAP;

EID: 84864666993     PISSN: 09387994     EISSN: 14321084     Source Type: Journal    
DOI: 10.1007/s00330-012-2458-6     Document Type: Article
Times cited : (10)

References (23)
  • 1
    • 34547669112 scopus 로고    scopus 로고
    • Frequency of stent fracture as a cause of coronary restenosis after sirolimus-eluting stent implantation
    • Lee SH, Park JS, Shin DG et al (2007) Frequency of stent fracture as a cause of coronary restenosis after sirolimus-eluting stent implantation. Am J Cardiol 100:627-630
    • (2007) Am J Cardiol , vol.100 , pp. 627-630
    • Lee, S.H.1    Park, J.S.2    Shin, D.G.3
  • 4
    • 58149260373 scopus 로고    scopus 로고
    • Significant association of coronary stent fracture with in-stent restenosis in sirolimus-eluting stents
    • Kim JS, Lee SY, Lee JM et al (2009) Significant association of coronary stent fracture with in-stent restenosis in sirolimus-eluting stents. Coron Artery Dis 20:59-63
    • (2009) Coron Artery Dis , vol.20 , pp. 59-63
    • Kim, J.S.1    Lee, S.Y.2    Lee, J.M.3
  • 5
    • 63149164938 scopus 로고    scopus 로고
    • Incidence and predictors of drug-eluting stent fractures in long coronary disease
    • Kim HS, Kim YH, Lee SWet al (2009) Incidence and predictors of drug-eluting stent fractures in long coronary disease. Int J Cardiol 133:354-358
    • (2009) Int J Cardiol , vol.133 , pp. 354-358
    • Kim, H.S.1    Kim, Y.H.2    Lee, S.W.3
  • 6
    • 70350734161 scopus 로고    scopus 로고
    • Incidence and predictors of drug-eluting stent fracture in human coronary artery -A pathologic analysis
    • Nakazawa G, Finn AV, Vorpahl M et al (2009) Incidence and predictors of drug-eluting stent fracture in human coronary artery -A pathologic analysis. J Am Coll Cardiol 54:1924-1931
    • (2009) J Am Coll Cardiol , vol.54 , pp. 1924-1931
    • Nakazawa, G.1    Finn, A.V.2    Vorpahl, M.3
  • 7
    • 58149196706 scopus 로고    scopus 로고
    • Coronary stent fracture: Detection with 64-section multidetector CT angiography in patients and in vitro
    • Lim HB, Hur G, Kim SY et al (2008) Coronary stent fracture: Detection with 64-section multidetector CT angiography in patients and in vitro. Radiology 249:810-819
    • (2008) Radiology , vol.249 , pp. 810-819
    • Lim, H.B.1    Hur, G.2    Kim, S.Y.3
  • 8
    • 78650789397 scopus 로고    scopus 로고
    • Clinical characteristics of coronary drug-eluting stent fracture: Insights from a two-center des registry
    • Park KW, Park JJ, Chae IH et al (2011) Clinical characteristics of coronary drug-eluting stent fracture: Insights from a two-center des registry. J Korean Med Sci 26:53-58
    • (2011) J Korean Med Sci , vol.26 , pp. 53-58
    • Park, K.W.1    Park, J.J.2    Chae, I.H.3
  • 9
    • 78650796471 scopus 로고    scopus 로고
    • Predictors of stent fracture in patients treated with closed-cell design stents: Sirolimus-eluting stent and its bare-metal counterpart, the BX velocity stent
    • Park SM, Kim JY, Hong BK et al (2011) Predictors of stent fracture in patients treated with closed-cell design stents: Sirolimus-eluting stent and its bare-metal counterpart, the BX velocity stent. Coron Artery Dis 22:40-44
    • (2011) Coron Artery Dis , vol.22 , pp. 40-44
    • Park, S.M.1    Kim, J.Y.2    Hong, B.K.3
  • 10
    • 33847339687 scopus 로고    scopus 로고
    • Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation
    • doi:10.1002/ccd.20950
    • Aoki J, Nakazawa G, Tanabe K et al (2007) Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation. Catheter Cardiovasc Interv 69:380-386. doi:10.1002/ccd.20950
    • (2007) Catheter Cardiovasc Interv , vol.69 , pp. 380-386
    • Aoki, J.1    Nakazawa, G.2    Tanabe, K.3
  • 11
    • 77957849281 scopus 로고    scopus 로고
    • Serial angiographic findings and prognosis of stent fracture site without early restenosis after sirolimus-eluting stent implantation
    • Ino Y, Toyoda Y, Tanaka A et al (2010) Serial angiographic findings and prognosis of stent fracture site without early restenosis after sirolimus-eluting stent implantation. Am Heart J 160:e771-e779
    • (2010) Am Heart J 160
    • Ino, Y.1    Toyoda, Y.2    Tanaka, A.3
  • 12
    • 84862002002 scopus 로고    scopus 로고
    • Long-term clinical and angiographic outcomes of patients with sirolimus-eluting stent fracture
    • doi:10.1016/j.ijcard.2011.01.013
    • Kim U, Kim DI, Kim DK et al (2011) Long-term clinical and angiographic outcomes of patients with sirolimus-eluting stent fracture. Int J Cardiol. doi:10.1016/j.ijcard.2011.01.013
    • (2011) Int J Cardiol.
    • Kim, U.1    Kim, D.I.2    Kim, D.K.3
  • 13
    • 79953755757 scopus 로고    scopus 로고
    • Late catch-up phenomenon associated with stent fracture after sirolimus-eluting stent implantation: Incidence and outcome
    • Serikawa T, Kawasaki T, Koga H et al (2011) Late catch-up phenomenon associated with stent fracture after sirolimus-eluting stent implantation: Incidence and outcome. J Interv Cardiol 24:165-171
    • (2011) J Interv Cardiol , vol.24 , pp. 165-171
    • Serikawa, T.1    Kawasaki, T.2    Koga, H.3
  • 14
    • 70350708668 scopus 로고    scopus 로고
    • Stent gap by 64-detector computed tomographic angiography relationship to in-stent restenosis, fracture, and overlap failure
    • Hecht HS, Polena S, Jelnin V et al (2009) Stent gap by 64-detector computed tomographic angiography relationship to in-stent restenosis, fracture, and overlap failure. J Am Coll Cardiol 54:1949-1959
    • (2009) J Am Coll Cardiol , vol.54 , pp. 1949-1959
    • Hecht, H.S.1    Polena, S.2    Jelnin, V.3
  • 15
    • 61649107928 scopus 로고    scopus 로고
    • Detection of stent fractures: A comparison of 64-slice CT, conventional cine-Angiography, and intravascular ultrasonography
    • Pang JH, Kim D, Beohar N, Meyers SN, Lloyd-Jones D, Yaghmai V (2009) Detection of stent fractures: A comparison of 64-slice CT, conventional cine-Angiography, and intravascular ultrasonography. Acad Radiol 16:412-417
    • (2009) Acad Radiol , vol.16 , pp. 412-417
    • Pang, J.H.1    Kim, D.2    Beohar, N.3    Meyers, S.N.4    Lloyd-Jones, D.5    Yaghmai, V.6
  • 16
    • 33847364564 scopus 로고    scopus 로고
    • Proximal vessel tortuosity and angulated lesions
    • In: Safian RD, FreedMS (eds), 3rd edn. Physicians's Press, Royal Oak, MI
    • Freed MS, Safian RD (2001) Proximal vessel tortuosity and angulated lesions. In: Safian RD, FreedMS (eds)Manual of interventional cardiology, 3rd edn. Physicians's Press, Royal Oak, MI, pp 237-243
    • (2001) Manual of Interventional Cardiology , pp. 237-243
    • Freed, M.S.1    Safian, R.D.2
  • 18
    • 73249121409 scopus 로고    scopus 로고
    • Predictors and prognosis of stent fracture after sirolimus-eluting stent implantation
    • Ino Y, Toyoda Y, Tanaka A et al (2009) Predictors and prognosis of stent fracture after sirolimus-eluting stent implantation. Circ J 73:2036-2041
    • (2009) Circ J , vol.73 , pp. 2036-2041
    • Ino, Y.1    Toyoda, Y.2    Tanaka, A.3
  • 19
    • 46849097604 scopus 로고    scopus 로고
    • Evaluation of coronary stent patency and in-stent restenosis with dual-source CT coronary angiography without heart rate control
    • Oncel D, Oncel G, Tastan A, Tamci B (2008) Evaluation of coronary stent patency and in-stent restenosis with dual-source CT coronary angiography without heart rate control. AJR Am J Roentgenol 191:56-63
    • (2008) AJR Am J Roentgenol , vol.191 , pp. 56-63
    • Oncel, D.1    Oncel, G.2    Tastan, A.3    Tamci, B.4
  • 20
    • 46249105311 scopus 로고    scopus 로고
    • Dual source coronary computed tomography angiography for detecting in-stent restenosis
    • Pugliese F,Weustink AC, Van Mieghem C et al (2008) Dual source coronary computed tomography angiography for detecting in-stent restenosis. Heart 94:848-854
    • (2008) Heart , vol.94 , pp. 848-854
    • Pugliese, F.1    Weustink, A.C.2    Van Mieghem, C.3
  • 21
    • 61349112750 scopus 로고    scopus 로고
    • Noninvasive assessment of coronary in-stent restenosis by dual-source computed tomography
    • Pflederer T, Marwan M, Renz A et al (2009) Noninvasive assessment of coronary in-stent restenosis by dual-source computed tomography. Am J Cardiol 103:812-817
    • (2009) Am J Cardiol , vol.103 , pp. 812-817
    • Pflederer, T.1    Marwan, M.2    Renz, A.3
  • 22
    • 36949022503 scopus 로고    scopus 로고
    • Restenosis and stent fracture following sirolimus-eluting stent (SES) implantation
    • Okumura M, Ozaki Y, Ishii J et al (2007) Restenosis and stent fracture following sirolimus-eluting stent (SES) implantation. Circ J 71:1669-1677
    • (2007) Circ J , vol.71 , pp. 1669-1677
    • Okumura, M.1    Ozaki, Y.2    Ishii, J.3
  • 23
    • 67349109381 scopus 로고    scopus 로고
    • Clinical outcomes and optimal treatment for stent fracture after drug-eluting stent implantation
    • Lee SE, Jeong MH, Kim IS et al (2009) Clinical outcomes and optimal treatment for stent fracture after drug-eluting stent implantation. J Cardiol 53:422-428
    • (2009) J Cardiol , vol.53 , pp. 422-428
    • Lee, S.E.1    Jeong, M.H.2    Kim, I.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.