Volumn , Issue , 2011, Pages 6825-6828

Replication of the Frank-Starling response in a mock circulation loop

Author keywords

[No Author keywords available]

Indexed keywords

CARDIOVASCULAR DEVICES; END-DIASTOLIC; END-SYSTOLIC; HUMAN DATA; IN-VIVO; MOCK CIRCULATION; PATHOLOGICAL CONDITIONS; PRELOADS; PROPORTIONAL CONTROLLER; RIGHT VENTRICULAR; TEST RIGS;

EID: 84864613324     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2011.6091683     Document Type: Conference Paper
Times cited : (61)

References (16)
  • 1
    • 84055206668 scopus 로고    scopus 로고
    • A compact mock circulation loop for the in vitro testing of cardiovascular devices
    • IN PRESS
    • Timms, D., et al., A compact mock circulation loop for the in vitro testing of cardiovascular devices. Artificial Organs, 2010. IN PRESS.
    • (2010) Artificial Organs
    • Timms, D.1
  • 2
    • 0347416922 scopus 로고    scopus 로고
    • Hemolysis in an electromechanical driven pulsatile total artificial heart
    • Ohashi, Y., A. Andrade, and Y. Nose, Hemolysis in an electromechanical driven pulsatile total artificial heart. Artificial organs, 2003. 27(12): p. 1089-1093.
    • (2003) Artificial Organs , vol.27 , Issue.12 , pp. 1089-1093
    • Ohashi, Y.1    Andrade, A.2    Nose, Y.3
  • 3
    • 22844448779 scopus 로고    scopus 로고
    • Design and initial testing of a mock human circulatory loop for left ventricular assist device performance testing
    • Liu, Y., et al., Design and initial testing of a mock human circulatory loop for left ventricular assist device performance testing. Artificial organs, 2005. 29(4): p. 341-345.
    • (2005) Artificial Organs , vol.29 , Issue.4 , pp. 341-345
    • Liu, Y.1
  • 4
    • 27744458446 scopus 로고    scopus 로고
    • Ascending aorta outflow graft location and pulsatile ventricular assist provide optimal hemodynamic support in an adult mock circulation
    • Litwak, K., et al., Ascending aorta outflow graft location and pulsatile ventricular assist provide optimal hemodynamic support in an adult mock circulation. Artificial organs, 2005. 29(8): p. 629-635.
    • (2005) Artificial Organs , vol.29 , Issue.8 , pp. 629-635
    • Litwak, K.1
  • 5
    • 0034173930 scopus 로고    scopus 로고
    • Evaluation of four blood pump geometries: Fluorescent particle flow visualisation technique
    • Rose, M., T. Mackay, and D. Wheatley, Evaluation of four blood pump geometries: fluorescent particle flow visualisation technique. Medical Engineering & Physics, 2000. 22: p. 201-214.
    • (2000) Medical Engineering & Physics , vol.22 , pp. 201-214
    • Rose, M.1    MacKay, T.2    Wheatley, D.3
  • 6
    • 2542443814 scopus 로고    scopus 로고
    • Particle image velocimetry for flow analysis in longitudinal planes across a mechanical artificial heart valve
    • Castellini, P., M. Pinotti, and L. Scalise, Particle image velocimetry for flow analysis in longitudinal planes across a mechanical artificial heart valve. Artificial organs, 2004. 28(5): p. 507-513.
    • (2004) Artificial Organs , vol.28 , Issue.5 , pp. 507-513
    • Castellini, P.1    Pinotti, M.2    Scalise, L.3
  • 7
    • 0019799237 scopus 로고
    • Design and evaluation of the Pennsylvania State University Mock Circulatory System
    • Rosenberg, G., et al., Design and evaluation of the Pennsylvania State University Mock Circulatory System. ASAIO, 1981. 4(April/June): p. 41-49.
    • (1981) ASAIO , vol.4 , Issue.APRIL , pp. 41-49
    • Rosenberg, G.1
  • 8
    • 0026754569 scopus 로고
    • A modular mock circulation for hydromechanical studies on valves, stenoses, vascular grafts and cardiac assist devices
    • Schima, H., et al., A modular mock circulation for hydromechanical studies on valves, stenoses, vascular grafts and cardiac assist devices. The International Journal of Artificial Organs, 1992. 15(7): p. 417-421.
    • (1992) The International Journal of Artificial Organs , vol.15 , Issue.7 , pp. 417-421
    • Schima, H.1
  • 10
    • 23744500968 scopus 로고    scopus 로고
    • Assessment of systolic and diastolic ventricular properties via pressure-volume analysis: A guid for clinical, translational, and basic researchers
    • Burkhoff, D., I. Mirsky, and H. Suga, Assessment of systolic and diastolic ventricular properties via pressure-volume analysis: a guid for clinical, translational, and basic researchers. Am J Physiol Heart Circ Physiol, 2005. 289: p. H501-H512.
    • (2005) Am J Physiol Heart Circ Physiol , vol.289
    • Burkhoff, D.1    Mirsky, I.2    Suga, H.3
  • 11
    • 8744230601 scopus 로고    scopus 로고
    • Feedback control design for an elastance-based mock circulatory system
    • Loh, M. and Y. Yu, Feedback control design for an elastance-based mock circulatory system. American Control Conference, 2004. Proceedings of the 2004, 2004. 2: p. 1639-1644.
    • (2004) American Control Conference, 2004. Proceedings of the 2004 , vol.2 , pp. 1639-1644
    • Loh, M.1    Yu, Y.2
  • 12
    • 0348230939 scopus 로고    scopus 로고
    • Characterization of an adult mock circulation for testing cardiac support devices
    • Pantalos, G., et al., Characterization of an adult mock circulation for testing cardiac support devices. ASAIO, 2004. 50(1): p. 37-46.
    • (2004) ASAIO , vol.50 , Issue.1 , pp. 37-46
    • Pantalos, G.1
  • 13
    • 0019405518 scopus 로고
    • The end-systolic pressure-volume relation of the ventricle: Definition, modifications and clinical use
    • Sagawa, K., The end-systolic pressure-volume relation of the ventricle: definition, modifications and clinical use. Circulation, 1981. 63: p. 1223-1227.
    • (1981) Circulation , vol.63 , pp. 1223-1227
    • Sagawa, K.1
  • 14
    • 0031937479 scopus 로고    scopus 로고
    • A computer controlled mock circulatory system for mono-and biventricular assist device testing
    • Ferrari, G., et al., A computer controlled mock circulatory system for mono-and biventricular assist device testing. The International Journal of Artificial Organs, 1998. 21(1): p. 26-36.
    • (1998) The International Journal of Artificial Organs , vol.21 , Issue.1 , pp. 26-36
    • Ferrari, G.1
  • 16
    • 0023789871 scopus 로고
    • Human right ventricular end-systolic pressure-volume relation defined by maximal elastance
    • Brown, K.A. and R.V. Ditchey, Human right ventricular end-systolic pressure-volume relation defined by maximal elastance. Circulation, 1988. 78: p. 81-91.
    • (1988) Circulation , vol.78 , pp. 81-91
    • Brown, K.A.1    Ditchey, R.V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.