1
-
-
0016617573
-
Design of a hydraulic analog of the circulatory system for evaluating artificial hearts
-
Donovan FM jr Design of a hydraulic analog of the circulatory system for evaluating artificial hearts. Biomaterials Medical Devices Artificial Organs 1975; 3: 439-49.
-
(1975)
Biomaterials Medical Devices Artificial Organs
, vol.3
, pp. 439-449
-
-
Donovan Jr., F.M.1
-
2
-
-
0019799237
-
Design and evaluation of the Pennsylvania State University mock circulatory system
-
Rosenberg G, Phillips WM, Landis DL, Pierce WS. Design and evaluation of the Pennsylvania State University mock circulatory system. ASAIO J 1981; 4: 41-9.
-
(1981)
ASAIO J
, vol.4
, pp. 41-49
-
-
Rosenberg, G.1
Phillips, W.M.2
Landis, D.L.3
Pierce, W.S.4
-
3
-
-
0021222775
-
A new test circulatory system for research in cardiovascular engineering
-
Arabia M, Akutsu T. A new test circulatory system for research in cardiovascular engineering. Ann Biomed Eng 1984; 12: 29-48.
-
(1984)
Ann Biomed Eng
, vol.12
, pp. 29-48
-
-
Arabia, M.1
Akutsu, T.2
-
4
-
-
0017365916
-
A simple cardiovascular system simulator: Design and performance
-
Swanson WM, Clark RE. A simple cardiovascular system simulator: design and performance. J Bioeng 1977; 1: 135-45.
-
(1977)
J Bioeng
, vol.1
, pp. 135-145
-
-
Swanson, W.M.1
Clark, R.E.2
-
5
-
-
0025993975
-
Development of mock circulation models for the assessment of counter pulsation systems
-
Bowles CT, Shah SS, Nishimura K, et al. Development of mock circulation models for the assessment of counter pulsation systems. Cardiovasc Res 1991; 11: 901-8.
-
(1991)
Cardiovasc Res
, vol.11
, pp. 901-908
-
-
Bowles, C.T.1
Shah, S.S.2
Nishimura, K.3
-
6
-
-
0026754569
-
A modular mock circulation for hydromechanical studies on valves, stenoses, vascular grafts and cardiac assist devices
-
Schima H, Baumgartner H, Spitaler F, Kuhn P, Wolner E. A modular mock circulation for hydromechanical studies on valves, stenoses, vascular grafts and cardiac assist devices, Int J Artif Organs 1992; 15(7): 417-21.
-
(1992)
Int J Artif Organs
, vol.15
, Issue.7
, pp. 417-421
-
-
Schima, H.1
Baumgartner, H.2
Spitaler, F.3
Kuhn, P.4
Wolner, E.5
-
7
-
-
0242705900
-
In vitro evaluation of artificial heart valves
-
Ghista DN, Van Vollenhoven E, Yang WJ, Reaul H, Bleifeld W eds. Basel: Karger
-
Reul H. In vitro evaluation of artificial heart valves. In: Ghista DN, Van Vollenhoven E, Yang WJ, Reaul H, Bleifeld W eds. Advances in cardiovascular Physics. Cardiovascular engineering. Part IV: prostheses, assist and artificial organs. Basel: Karger 1983; 5: 16-30.
-
(1983)
Advances in Cardiovascular Physics. Cardiovascular Engineering. Part IV: Prostheses, Assist and Artificial Organs
, vol.5
, pp. 16-30
-
-
Reul, H.1
-
8
-
-
0026557117
-
Compact mock loops of the systemic and pulmonary circulation for blood pump testing
-
Knierbein B, Reul H, Eilers R, Lange M, Kaufmann R, Rau C. Compact mock loops of the systemic and pulmonary circulation for blood pump testing, Int J Artif Organs 1992; 15: 40-8.
-
(1992)
Int J Artif Organs
, vol.15
, pp. 40-48
-
-
Knierbein, B.1
Reul, H.2
Eilers, R.3
Lange, M.4
Kaufmann, R.5
Rau, C.6
-
9
-
-
0029866610
-
In vitro testing of a left ventricular assist device: Study of the effect of its control strategy on energetic relationships inside the left ventricle
-
Ferrari G, Górczynska K, De Lazzari C, et al. In vitro testing of a left ventricular assist device: study of the effect of its control strategy on energetic relationships inside the left ventricle. Technol Health Care 1996; 3: 231-9.
-
(1996)
Technol Health Care
, vol.3
, pp. 231-239
-
-
Ferrari, G.1
Górczynska, K.2
De Lazzari, C.3
-
10
-
-
6844263934
-
A new hydraulic simulator of the circulatory system. Some experimental results in reproducing a physiological and a pathological state
-
Ferrari G, Mimmo R, Tosti G, Górczynska K, Grodzicki K. A new hydraulic simulator of the circulatory system. Some experimental results in reproducing a physiological and a pathological state. Biocybernetics and Biomedical Engineering 1987: 87-103.
-
(1987)
Biocybernetics and Biomedical Engineering
, pp. 87-103
-
-
Ferrari, G.1
Mimmo, R.2
Tosti, G.3
Górczynska, K.4
Grodzicki, K.5
-
11
-
-
0026193529
-
A sophisticated electromechanical ventricular simulator for ventricular assist system testing
-
Woodard JC, Rock SM, Portner PM. A sophisticated electromechanical ventricular simulator for ventricular assist system testing. ASAIO Trans 1991; 37: M210-11.
-
(1991)
ASAIO Trans
, vol.37
-
-
Woodard, J.C.1
Rock, S.M.2
Portner, P.M.3
-
12
-
-
0027933590
-
A mock circulatory system for in vitro reproduction of the left ventricle, the arterial tree and their interaction with a left ventricle assist device
-
Ferrari G, De Lazzari C, Mimmo R, Tosti G, Ambrosi D. A mock circulatory system for in vitro reproduction of the left ventricle, the arterial tree and their interaction with a left ventricle assist device. J Med Eng Technol 1994; 18: 87-95.
-
(1994)
J Med Eng Technol
, vol.18
, pp. 87-95
-
-
Ferrari, G.1
De Lazzari, C.2
Mimmo, R.3
Tosti, G.4
Ambrosi, D.5
-
15
-
-
0004115505
-
Arterial Impedance
-
Hwang NHC, Gross DR and Patel DJ eds. Baltimore: University Park Press
-
Westerhof N, Sipkema P, Elzinga G, Murgo JP, Giolma JP. Arterial Impedance. In: Hwang NHC, Gross DR and Patel DJ eds. Quantitative Cardiovascular Studies. Baltimore: University Park Press, 1979; 111-50.
-
(1979)
Quantitative Cardiovascular Studies
, pp. 111-150
-
-
Westerhof, N.1
Sipkema, P.2
Elzinga, G.3
Murgo, J.P.4
Giolma, J.P.5
-
16
-
-
0015147582
-
An artificial arterial system for pumping hearts
-
Westerhof N, Elzinga G, Sipkema P. An artificial arterial system for pumping hearts. J Appl Physiol 1971; 31: 776-81.
-
(1971)
J Appl Physiol
, vol.31
, pp. 776-781
-
-
Westerhof, N.1
Elzinga, G.2
Sipkema, P.3
-
18
-
-
0021748969
-
Impedance matching between ventricle and load
-
Piene H. Impedance matching between ventricle and load. Ann Biomedl Eng 1984; 12: 191-207.
-
(1984)
Ann Biomedl Eng
, vol.12
, pp. 191-207
-
-
Piene, H.1
-
19
-
-
0026505807
-
A modular numerical model of the cardiovascular system for studying and training in the field of cardiovascular physiopathology
-
Ferrari G, De Lazzari C, Mimmo R, Tosti G, Ambrosi D. A modular numerical model of the cardiovascular system for studying and training in the field of cardiovascular physiopathology. J Biomed Eng 1992; 14: 91-107.
-
(1992)
J Biomed Eng
, vol.14
, pp. 91-107
-
-
Ferrari, G.1
De Lazzari, C.2
Mimmo, R.3
Tosti, G.4
Ambrosi, D.5
-
20
-
-
0024553925
-
Determinants of left ventricular filling and of the diastolic pressure-volume relation
-
Gilbert JC, Glantz SA. Determinants of left ventricular filling and of the diastolic pressure-volume relation. Circ Res 1989; 64: 827-52.
-
(1989)
Circ Res
, vol.64
, pp. 827-852
-
-
Gilbert, J.C.1
Glantz, S.A.2
-
21
-
-
0029866610
-
In vitro testing of a left ventricular assist device: Study of the effect of its control strategy on energetic relationships inside the left ventricle
-
Ferrari G, Górczynska K, De Lazzari C, et al. In vitro testing of a left ventricular assist device: study of the effect of its control strategy on energetic relationships inside the left ventricle. Technol Health Care 1996; 3: 231-9.
-
(1996)
Technol Health Care
, vol.3
, pp. 231-239
-
-
Ferrari, G.1
Górczynska, K.2
De Lazzari, C.3
-
22
-
-
0028899846
-
Left ventricular contractility predicts how the end-diastolic pressure-volume relation shifts during pacing-induced ischemia in dogs
-
Takano H, Glantz SA. Left ventricular contractility predicts how the end-diastolic pressure-volume relation shifts during pacing-induced ischemia in dogs. Circulation 1995; 91: 2423-34.
-
(1995)
Circulation
, vol.91
, pp. 2423-2434
-
-
Takano, H.1
Glantz, S.A.2
|