메뉴 건너뛰기




Volumn 27, Issue 3, 2012, Pages 725-736

Integrated modeling and enhanced control of DFIG under unbalanced and distorted grid voltage conditions

Author keywords

Control; doubly fed induction generator (DFIG); modeling; unbalanced and distorted grid voltage conditions; wind power

Indexed keywords

CONTROL STRATEGIES; CONTROL TARGET; CONVENTIONAL PI; CURRENT CONTROLLER; DEVELOPED MODEL; DISTORTED GRID VOLTAGE; DOUBLY FED INDUCTION GENERATORS; DUAL FREQUENCY; EXPERIMENT STUDY; FAULT RIDE-THROUGH; GRID CONDITIONS; GRID FREQUENCY; GRID VOLTAGE; HARMONIC COMPONENTS; INTEGRATED MODELING; LOW ORDER HARMONICS; ROTOR CURRENT; WIND TURBINE SYSTEMS;

EID: 84864584724     PISSN: 08858969     EISSN: None     Source Type: Journal    
DOI: 10.1109/TEC.2012.2199495     Document Type: Article
Times cited : (112)

References (21)
  • 1
    • 0036575603 scopus 로고    scopus 로고
    • Doubly fed induction generator systems for wind turbines
    • DOI 10.1109/2943.999610
    • S. Muller, M. Deicke, and R. W. De Doncker, "Doubly fed induction generator systems for wind turbines," IEEE Ind. Appl. Mag., vol. 8, no. 3, pp. 26-33, May/Jun. 2002. (Pubitemid 34630524)
    • (2002) IEEE Industry Applications Magazine , vol.8 , Issue.3 , pp. 26-33
    • Muller, S.1    Deicke, M.2    De Doncker, R.W.3
  • 2
    • 77954587061 scopus 로고    scopus 로고
    • Magnitude and frequency control of grid-connected doubly fed induction generator based on synchronized model for wind power generation
    • May
    • Z. Wang, Y. Sun, G. Li, and B. T. Ooi, "Magnitude and frequency control of grid-connected doubly fed induction generator based on synchronized model for wind power generation," IET Renew. Power Gener., vol. 4, no. 3, pp. 232-241, May 2010.
    • (2010) IET Renew. Power Gener , vol.4 , Issue.3 , pp. 232-241
    • Wang, Z.1    Sun, Y.2    Li, G.3    Ooi, B.T.4
  • 3
    • 77951998912 scopus 로고    scopus 로고
    • A dynamic lvrt solution for doubly fed induction generators
    • Jan
    • O. Abdel-Baqi and A. Nasiri, "A dynamic LVRT solution for doubly fed induction generators," IEEE Trans. Power Electron., vol. 25, no. 1, pp. 193-196, Jan. 2010.
    • (2010) IEEE Trans. Power Electron. , vol.25 , Issue.1 , pp. 193-196
    • Abdel-Baqi, O.1    Nasiri, A.2
  • 4
    • 44449177072 scopus 로고    scopus 로고
    • Low voltage ride through of wind farms with cage generators: STATCOM versus SVC
    • DOI 10.1109/TPEL.2008.921169
    • M.Molinas, Jon Are Suul, and T. Undeland, "Low voltage ride through of wind farms with cage generators: STATCOM versus SVC," IEEE Trans. Ind. Electron., vol. 23, no. 3, pp. 1104-1117, May 2008. (Pubitemid 351760755)
    • (2008) IEEE Transactions on Power Electronics , vol.23 , Issue.3 , pp. 1104-1117
    • Molinas, M.1    Suul, J.A.2    Undeland, T.3
  • 5
    • 77949897659 scopus 로고    scopus 로고
    • Effects of voltage unbalance and system harmonics on the performance of doubly fed induction wind generators
    • Mar
    • M. Kiani andW. J. Lee, "Effects of voltage unbalance and system harmonics on the performance of doubly fed induction wind generators," IEEE Trans. Ind. Appl., vol. 46, no. 2, pp. 562-569, Mar. 2010.
    • (2010) IEEE Trans. Ind. Appl. , vol.46 , Issue.2 , pp. 562-569
    • Kiani, M.1    Lee, W.J.2
  • 6
    • 78649532005 scopus 로고    scopus 로고
    • Influence of supply harmonic voltages on dfig stator current and power spectrum
    • Rome, Italy, Sep.
    • S. Djurovíc and S.Williamson, "Influence of supply harmonic voltages on DFIG stator current and power spectrum," in Proc. XIX Int. Conf. Electr. Mach., Rome, Italy, Sep. 2010, pp. 1-6.
    • (2010) Proc. XIX Int. Conf. Electr. Mach. , pp. 1-6
    • Djurovíc, S.1    Williamson, S.2
  • 7
    • 76649130518 scopus 로고    scopus 로고
    • A variable speed wind turbine control strategy to meet wind farm grid code requirements
    • Feb
    • S.M.Muyeen, R. Takahashi, T.Murata, and J. Tamura, "A variable speed wind turbine control strategy to meet wind farm grid code requirements," IEEE Trans. Power Syst., vol. 25, no. 1, pp. 331-340, Feb. 2010.
    • (2010) IEEE Trans. Power Syst. , vol.25 , Issue.1 , pp. 331-340
    • Muyeen, S.M.1    Takahashi, R.2    Murata, T.3    Tamura, J.4
  • 8
    • 33947313847 scopus 로고    scopus 로고
    • Dynamic modeling and control of DFIG-based wind turbines under unbalanced network conditions
    • DOI 10.1109/TPWRS.2006.889113
    • L. Xu and Y.Wang, "Dynamic modeling and control of DFIG based wind turbines under unbalanced network conditions," IEEE Trans. Power Sys., vol. 22, no. 1, pp. 314-323, Feb. 2007. (Pubitemid 46437741)
    • (2007) IEEE Transactions on Power Systems , vol.22 , Issue.1 , pp. 314-323
    • Xu, L.1    Wang, Y.2
  • 9
    • 34249802057 scopus 로고    scopus 로고
    • Control system for unbalanced operation of stand-alone doubly fed induction generators
    • DOI 10.1109/TEC.2007.895393
    • R. Pena, R. Cardenas, E. Escobar, J. Clare, and P. Wheeler, "Control system for unbalanced operation of stand-alone doubly fed induction generators," IEEE Trans. Energy Convers., vol. 22, no. 2, pp. 544-545, Jun. 2007. (Pubitemid 46845657)
    • (2007) IEEE Transactions on Energy Conversion , vol.22 , Issue.2 , pp. 544-545
    • Pena, R.1    Cardenas, R.2    Escobar, E.3    Clare, J.4    Wheeler, P.5
  • 10
    • 60449101280 scopus 로고    scopus 로고
    • Improved control of dfig systems during network unbalance using pi-r current regulators
    • Feb.
    • J. Hu, Y. He, L. Xu, and B. W. Williams, "Improved control of DFIG systems during network unbalance using PI-R current regulators," IEEE Trans. Ind. Electron., vol. 56, no. 2, pp. 439-459, Feb. 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.2 , pp. 439-459
    • Hu, J.1    He, Y.2    Xu, L.3    Williams, B.W.4
  • 11
    • 79956312957 scopus 로고    scopus 로고
    • Improved predictive current control for unbalanced stand-alone doubly-fed induction generator-based wind power systems
    • Mar
    • V.-T. Phan and H.-H Lee, "Improved predictive current control for unbalanced stand-alone doubly-fed induction generator-based wind power systems," IET Electric Power Appl., vol. 5, no. 3, pp. 275-287, Mar. 2011.
    • (2011) IET Electric Power Appl. , vol.5 , Issue.3 , pp. 275-287
    • Phan, V.-T.1    H.-H Lee2
  • 12
    • 77249175320 scopus 로고    scopus 로고
    • Directpower control of doubly-fed-induction-generator-based wind turbines under unbalanced grid voltage
    • Feb
    • G. Abad,M. A. Rodriguez, G. Iwanski, and J. Poza, "Directpower control of doubly-fed-induction-generator-based wind turbines under unbalanced grid voltage," IEEE Trans. Power Electron., vol. 25, no. 2, pp. 442-452, Feb. 2010.
    • (2010) IEEE Trans. Power Electron. , vol.25 , Issue.2 , pp. 442-452
    • Abad, G.1    Iwanski, G.2    Poza, J.3
  • 13
    • 84862807192 scopus 로고    scopus 로고
    • Sliding-mode-based direct power control of gridconnected wind-turbine driven doubly fed induction generators under unbalanced grid voltage conditions
    • Jun
    • L. Shang and J. Hu, "Sliding-mode-based direct power control of gridconnected wind-turbine driven doubly fed induction generators under unbalanced grid voltage conditions," IEEE Trans. Energy Convers., vol. 27, no. 2, pp. 362-373, Jun. 2012.
    • (2012) IEEE Trans. Energy Convers. , vol.27 , Issue.2 , pp. 362-373
    • Shang, L.1    Hu, J.2
  • 14
    • 77952951957 scopus 로고    scopus 로고
    • Integral sliding-mode direct torque control of doubly-fed induction generators under unbalanced grid voltage
    • Jun
    • C. S. Zhe, N. C. Cheung,W. K. Chung, andW. Jie, "Integral sliding-mode direct torque control of doubly-fed induction generators under unbalanced grid voltage," IEEE Trans. Energy Convers., vol. 25, no. 2, pp. 356-368, Jun. 2010.
    • (2010) IEEE Trans. Energy Convers. , vol.25 , Issue.2 , pp. 356-368
    • Zhe, C.S.1    Cheung, N.C.2    Chung, W.K.3    Jie, W.4
  • 15
    • 66549125385 scopus 로고    scopus 로고
    • Design of an output lc filter for a doubly fed induction generator supplying non-linear loads for aircraft applications
    • May
    • F. Khatounian and E. Monmasson, "Design of an output LC filter for a doubly fed induction generator supplying non-linear loads for aircraft applications," in Proc. IEEE Int. Symp. Ind. Electron., May, 2004, pp. 1093-1098.
    • (2004) Proc. IEEE Int. Symp. Ind. Electron. , pp. 1093-1098
    • Khatounian, F.1    Monmasson, E.2
  • 16
    • 78649588561 scopus 로고    scopus 로고
    • Simulation of a dfig-based wind turbine with active filtering function using matlab/simulink
    • Rome, Italy, Sep.
    • H. Djeghloud, A. Bentounsi, andH. Benalla, "Simulation of a DFIG-based wind turbine with active filtering function using MATLAB/Simulink," in Proc. Int. Conf. Electr. Mach., Rome, Italy, Sep. 2010, pp. 1-7.
    • (2010) Proc. Int. Conf. Electr. Mach. , pp. 1-7
    • Djeghloud, H.1    Bentounsi, A.2    Benalla, H.3
  • 17
    • 57849127165 scopus 로고    scopus 로고
    • Active filtering capability of wecs with dfig for grid power quality improvement
    • Jun. 30
    • A. Gaillard, P. Poure, and S. Saadate, "Active filtering capability of WECS with DFIG for grid power quality improvement," in Proc. IEEE Int. Symp. Ind. Electron., Jun. 30, 2008, pp. 2365-2370.
    • (2008) Proc. IEEE Int. Symp. Ind. Electron. , pp. 2365-2370
    • Gaillard, A.1    Poure, P.2    Saadate, S.3
  • 18
    • 49949090608 scopus 로고    scopus 로고
    • Rotor current controller with voltage harmonics compensation for a dfig operating under unbalanced and distorted stator voltage
    • Nov. 5-8
    • C. J. Ramos, A. P. Martins, and A. S. Carvalho, "Rotor current controller with voltage harmonics compensation for a DFIG operating under unbalanced and distorted stator voltage," in Proc. 33rd Annu. Conf. IEEE Ind. Electron. Soc., Taipei, Taiwan, Nov. 5-8, 2007, pp. 1287-1292.
    • (2007) Proc. 33rd Annu. Conf. IEEE Ind. Electron. Soc., Taipei, Taiwan , pp. 1287-1292
    • Ramos, C.J.1    Martins, A.P.2    Carvalho, A.S.3
  • 19
    • 79951957728 scopus 로고    scopus 로고
    • Dynamic modeling and improved control of dfig under distorted grid voltage conditions
    • Mar
    • J. Hu, H. Nian, H. Xu, and Y. He, "Dynamic modeling and improved control of DFIG under distorted grid voltage conditions," IEEE Trans. Energy Convers., vol. 26, no. 1, pp. 163-175, Mar. 2011.
    • (2011) IEEE Trans. Energy Convers. , vol.26 , Issue.1 , pp. 163-175
    • Hu, J.1    Nian, H.2    Xu, H.3    He, Y.4
  • 20
    • 5044242022 scopus 로고    scopus 로고
    • High performance harmonic extraction algorithm for a 25 kv traction power quality conditioner
    • Sep.
    • P. C. Tan, P. C. Loh, and D. G. Homes, "High performance harmonic extraction algorithm for a 25 kV traction power quality conditioner," IEE Proc.-Electr. Power Appl., vol. 151, no. 5, pp. 505-512, Sep. 2004.
    • (2004) IEE Proc.-Electr. Power Appl. , vol.151 , Issue.5 , pp. 505-512
    • Tan, P.C.1    Loh, P.C.2    Homes, D.G.3
  • 21
    • 78650208824 scopus 로고    scopus 로고
    • Multiresonant frequency-locked loop for grid synchronization of power converters under distorted grid conditions
    • Jan
    • P. Rodríiguez, A. Luna, I. Candela, R. Mujal, R. Teodorescu, and F. Blaabjerg, "Multiresonant frequency-locked loop for grid synchronization of power converters under distorted grid conditions," IEEE Trans. Ind. Electron., vol. 58, no. 1, pp. 127-138, Jan. 2011.
    • (2011) IEEE Trans. Ind. Electron. , vol.58 , Issue.1 , pp. 127-138
    • Rodríiguez, P.1    Luna, A.2    Candela, I.3    Mujal, R.4    Teodorescu, R.5    Blaabjerg, F.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.