메뉴 건너뛰기




Volumn 151, Issue 5, 2004, Pages 505-512

High-performance harmonic extraction algorithm for a 25 kV traction power quality conditioner

Author keywords

[No Author keywords available]

Indexed keywords

DC MOTOR DRIVES; DIGITAL RESONANT FILTERS; ELECTRIFIED RAILWAY SYSTEMS; POWER QUALITY CONDITIONERS;

EID: 5044242022     PISSN: 13502352     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1049/ip-epa:20040586     Document Type: Conference Paper
Times cited : (72)

References (16)
  • 2
    • 0042157049 scopus 로고    scopus 로고
    • A robust multilevel hybrid compensation system for 25 kV electrified railway applications
    • Acapulco, Mexico
    • Tan, P.C., Loh, P.C., and Holmes, D.G.: 'A robust multilevel hybrid compensation system for 25 kV electrified railway applications'. Proc. IEEE-PESC'03, Acapulco, Mexico, 2003, pp. 1020-1025
    • (2003) Proc. IEEE-PESC'03 , pp. 1020-1025
    • Tan, P.C.1    Loh, P.C.2    Holmes, D.G.3
  • 3
    • 0038015889 scopus 로고    scopus 로고
    • Voltage form factor control and reactive power compensation in a 25kV electrified railway system using a shunt active filter based on voltage detection
    • Tan, P.C., Morrison, R.E., and Holmes, D.G.: 'Voltage form factor control and reactive power compensation in a 25kV electrified railway system using a shunt active filter based on voltage detection', IEEE Trans. Ind. Appl., 2003, 39, pp. 575-581
    • (2003) IEEE Trans. Ind. Appl. , vol.39 , pp. 575-581
    • Tan, P.C.1    Morrison, R.E.2    Holmes, D.G.3
  • 4
    • 0030846989 scopus 로고    scopus 로고
    • Control strategy and site selection of a shunt active filter for damping of harmonic propagation in power distribution systems
    • Akagi, R: 'Control strategy and site selection of a shunt active filter for damping of harmonic propagation in power distribution systems', IEEE Trans. Power Deliv., 1996, 12, pp. 354-363
    • (1996) IEEE Trans. Power Deliv. , vol.12 , pp. 354-363
    • Akagi, R.1
  • 5
    • 85010985909 scopus 로고
    • Specification of an over-voltage damping filler for the national railways of Zimbabwe
    • Morrison, R.E., and Corcoran, J.C.W.: 'Specification of an over-voltage damping filler for the national railways of Zimbabwe', IEE Proc. B, Electr. Power. Appl., 1989, 136, pp. 249-256
    • (1989) IEE Proc. B, Electr. Power. Appl. , vol.136 , pp. 249-256
    • Morrison, R.E.1    Corcoran, J.C.W.2
  • 6
    • 0035273190 scopus 로고    scopus 로고
    • Frequency-domain analysis of three-phase linear current regulators
    • Zmood, D.N., Holmes, D.G., and Bode, G.H.: 'Frequency-domain analysis of three-phase linear current regulators', IEEE Trans. Ind. Appl., 2001, 37, pp. 601-610
    • (2001) IEEE Trans. Ind. Appl. , vol.37 , pp. 601-610
    • Zmood, D.N.1    Holmes, D.G.2    Bode, G.H.3
  • 8
    • 0029358962 scopus 로고
    • A three-phase active power fitter operating with fixed switching frequency for reactive power and current harmonic compensation
    • Moran, L.A., Dixon, J.W., and Wallace, R.R.: 'A three-phase active power fitter operating with fixed switching frequency for reactive power and current harmonic compensation', IEEE Trans. Ind. Electron., 1995, 42, pp. 402-408
    • (1995) IEEE Trans. Ind. Electron. , vol.42 , pp. 402-408
    • Moran, L.A.1    Dixon, J.W.2    Wallace, R.R.3
  • 10
    • 0035087921 scopus 로고    scopus 로고
    • A closed-loop selective harmonic compensation, for active filters
    • Mattavelli P.: 'A closed-loop selective harmonic compensation, for active filters', IEEE Trans. Ind. Appl., 2001, 37, pp. 81-89
    • (2001) IEEE Trans. Ind. Appl. , vol.37 , pp. 81-89
    • Mattavelli, P.1
  • 11
    • 0030289837 scopus 로고    scopus 로고
    • New tends in active fitters for power conditioning
    • Akagi, H.: 'New tends in active fitters for power conditioning', IEEE Trans. Ind. Appl, 1996, 32, pp. 1312-1322
    • (1996) IEEE Trans. Ind. Appl , vol.32 , pp. 1312-1322
    • Akagi, H.1
  • 12
    • 0028730179 scopus 로고
    • Comparison between differential real-time harmonic analysis methods for control of electrical machines
    • London, UK
    • Tnani, S., Mazaudier, M., Berthon, A., and Diop, S.: 'Comparison between differential real-time harmonic analysis methods for control of electrical machines'. Proc. PEVSD'94, London, UK, 1994, pp. 342-345
    • (1994) Proc. PEVSD'94 , pp. 342-345
    • Tnani, S.1    Mazaudier, M.2    Berthon, A.3    Diop, S.4
  • 14
    • 0022809661 scopus 로고
    • Improved finite word length characteristics in digital control using delta operators
    • Middleton, R.H., and Goodwill, G.C.: 'Improved finite word length characteristics in digital control using delta operators', IEEE Trans. Autom. Control, 1986, AC-31, pp. 1015-1021
    • (1986) IEEE Trans. Autom. Control , vol.AC-31 , pp. 1015-1021
    • Middleton, R.H.1    Goodwill, G.C.2
  • 16
    • 0037258724 scopus 로고    scopus 로고
    • Delta operator digital fitters for high performance inverter applications
    • Newman, M.J., and Holmes, D.G.: 'Delta operator digital fitters for high performance inverter applications', IEEE Trans. Power Electron., 2003, 18, pp. 447-454
    • (2003) IEEE Trans. Power Electron. , vol.18 , pp. 447-454
    • Newman, M.J.1    Holmes, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.