메뉴 건너뛰기




Volumn 18, Issue PART 1, 2011, Pages 4886-4891

Sort-synchronization control in microuidic loop devices with experimental uncertainties using a model predictive control (MPC) framework

Author keywords

Active control; Loop device; Microuidics; Model predictive control; Optimization; Sort synchronization

Indexed keywords

DROPS; OPTIMIZATION; PREDICTIVE CONTROL SYSTEMS; SYNCHRONIZATION;

EID: 84864504363     PISSN: 14746670     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.3182/20110828-6-IT-1002.03342     Document Type: Conference Paper
Times cited : (4)

References (17)
  • 1
    • 45749098177 scopus 로고    scopus 로고
    • Single-layer membrane valves for elastomeric microuidic devices
    • Abate, A.R. and Weitz, D.A. (2008). Single-layer membrane valves for elastomeric microuidic devices. Applied Physics Letters., 92, 243509(1)- 243509(3).
    • (2008) Applied Physics Letters. , vol.92 , pp. 2435091-2435093
    • Abate, A.R.1    Weitz, D.A.2
  • 2
    • 77952972579 scopus 로고    scopus 로고
    • Microuidic sorting with high-speed single layer membrane valves
    • Abate, A.R., Agresti, J.J., and Weitz, D.A. (2010). Microuidic sorting with high-speed single layer membrane valves. Applied Physics Letters., 96, 203509(1)- 203509(3).
    • (2010) Applied Physics Letters. , vol.96 , pp. 2035091-2035093
    • Abate, A.R.1    Agresti, J.J.2    Weitz, D.A.3
  • 3
    • 77950861207 scopus 로고    scopus 로고
    • Droplet position control in digital microuidic systems
    • Bhattacharjee, B. and Najjaran, H. (2010). Droplet position control in digital microuidic systems. Biomed Microdevices, 12, 115-124.
    • (2010) Biomed Microdevices , vol.12 , pp. 115-124
    • Bhattacharjee, B.1    Najjaran, H.2
  • 5
    • 33746281099 scopus 로고    scopus 로고
    • Microuidic bypass for efficient passive regulation of droplet traffic at a junction
    • Cristobal, G., Benoit, J.P., Jaonicot, M., and Ajdari, A. (2006). Microuidic bypass for efficient passive regulation of droplet traffic at a junction. Applied Physics Letters., 89, 034104(1)-034104(3).
    • (2006) Applied Physics Letters. , vol.89 , pp. 0341041-0341043
    • Cristobal, G.1    Benoit, J.P.2    Jaonicot, M.3    Ajdari, A.4
  • 6
    • 33846984899 scopus 로고    scopus 로고
    • Coding/decoding and reversibility of droplet trains in microuidic networks
    • Fuerstman, M.J., Garstecki, P., and Whitesides, G.M. (2007). Coding/decoding and reversibility of droplet trains in microuidic networks. Science, 315, 828-832.
    • (2007) Science , vol.315 , pp. 828-832
    • Fuerstman, M.J.1    Garstecki, P.2    Whitesides, G.M.3
  • 7
    • 34548077793 scopus 로고    scopus 로고
    • Microuidic platforms for lab-on-chip applications
    • Haeberle, S. and Zengerle III, R. (2007). Microuidic platforms for lab-on-chip applications. Lab Chip., 7, 1094-1110.
    • (2007) Lab Chip. , vol.7 , pp. 1094-1110
    • Haeberle, S.1    Zengerle III, R.2
  • 9
    • 76449086930 scopus 로고    scopus 로고
    • Droplet merging in a straight microchannel using droplet size or viscosity difference
    • Jin, B.J., Kim, Y.W., Lee, Y., and Yoo, J.Y. (2010). Droplet merging in a straight microchannel using droplet size or viscosity difference. J. Micromech Mi- croeng, 20, 035003(1)-035003(3).
    • (2010) J. Micromech Mi- Croeng , vol.20 , pp. 0350031-0350033
    • Jin, B.J.1    Kim, Y.W.2    Lee, Y.3    Yoo, J.Y.4
  • 10
    • 20844451163 scopus 로고    scopus 로고
    • Compact model for multi-phase liquid-liquid ows in microuidic devices
    • Jousse, F., Lian, G., Janes, R., and Melrose, J. (2005). Compact model for multi-phase liquid-liquid ows in microuidic devices. Lab Chip., 5, 646-656.
    • (2005) Lab Chip. , vol.5 , pp. 646-656
    • Jousse, F.1    Lian, G.2    Janes, R.3    Melrose, J.4
  • 11
    • 64149083405 scopus 로고    scopus 로고
    • Extracting the hydrodynamic resistance of droplets from their behavior in microchannel networks
    • Labrot, V., Schindler, M., Guillot, P., Colin, A., and Joanicot, M. (2009). Extracting the hydrodynamic resistance of droplets from their behavior in microchannel networks. BioMicrouidics., 3, 012804(1)-012804(16).
    • (2009) BioMicrouidics. , vol.3 , pp. 0128041-01280416
    • Labrot, V.1    Schindler, M.2    Guillot, P.3    Colin, A.4    Joanicot, M.5
  • 12
    • 84866749834 scopus 로고    scopus 로고
    • Design of a model-based feedback controller for active sorting and synchronization of droplets in microuidic loop
    • article submitted to
    • Maddala, J., Srinivasan, B., Bithi, S.S., Vanapalli, S.A., and Rengaswamy, R. (2010). Design of a model-based feedback controller for active sorting and synchronization of droplets in microuidic loop. article submitted to AIChE Journal.
    • (2010) AIChE Journal
    • Maddala, J.1    Srinivasan, B.2    Bithi, S.S.3    Vanapalli, S.A.4    Rengaswamy, R.5
  • 13
    • 33846960112 scopus 로고    scopus 로고
    • Microuidic bubble logic
    • Prakash, M. and Gershenfeld, N. (2007). Microuidic bubble logic. Science, 315, 832-835.
    • (2007) Science , vol.315 , pp. 832-835
    • Prakash, M.1    Gershenfeld, N.2
  • 14
    • 38749145562 scopus 로고    scopus 로고
    • Droplet traffic microuidic networks: A simple model for understanding and designing
    • Schindler, M. and Ajdari, A. (2008). Droplet traffic microuidic networks: A simple model for understanding and designing. Physical Review Letters., 100, 044501(1)- 044501(4).
    • (2008) Physical Review Letters. , vol.100 , pp. 0445011-0445014
    • Schindler, M.1    Ajdari, A.2
  • 15
    • 75149188155 scopus 로고    scopus 로고
    • Agent-based simulations of complex droplet pattern formation in a two-branch microuidic network
    • Smith, B.J. and Gaver III, D.P. (2010). Agent-based simulations of complex droplet pattern formation in a two-branch microuidic network. Lab Chip., 10, 303-312.
    • (2010) Lab Chip. , vol.10 , pp. 303-312
    • Smith, B.J.1    Gaver III, D.P.2
  • 16
    • 33751254091 scopus 로고    scopus 로고
    • Reactions in droplets in microuidic channels
    • Song, H., Chen, D.L., and Ismagilov, R.F. (2006). Reactions in droplets in microuidic channels. Angew. Chem. Int. Ed., 45, 7336-7356.
    • (2006) Angew. Chem. Int. Ed. , vol.45 , pp. 7336-7356
    • Song, H.1    Chen, D.L.2    Ismagilov, R.F.3
  • 17
    • 4444257582 scopus 로고    scopus 로고
    • Formation of droplets of alternating composition in micruidic channels and applications to indexing of concentrations in droplet based assays
    • Zheng, B., Tice, J.D., and Ismagilov, R.F. (2004). Formation of droplets of alternating composition in micruidic channels and applications to indexing of concentrations in droplet based assays. Anal Chem., 76, 4977-4982.
    • (2004) Anal Chem. , vol.76 , pp. 4977-4982
    • Zheng, B.1    Tice, J.D.2    Ismagilov, R.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.