메뉴 건너뛰기




Volumn 14, Issue SUPPL. 2, 2012, Pages

The role of percutaneous left ventricular assist devices during ventricular tachycardia ablation

Author keywords

Catheter ablation; Left ventricular assist device; Ventricular tachycardia

Indexed keywords

ANESTHESIA INDUCTION; AORTA BALLOON; BLEEDING; CATHETER ABLATION; EXTRACORPOREAL OXYGENATION; FEMOROFEMORAL BYPASS; HEART HEMODYNAMICS; HEART VENTRICLE TACHYCARDIA; IMPLANTATION; INFECTION; LEFT VENTRICULAR ASSIST DEVICE; LIMB ISCHEMIA; PATIENT MONITORING; PERCUTANEOUS CORONARY INTERVENTION; PRIORITY JOURNAL; REVIEW; THROMBOEMBOLISM;

EID: 84864441089     PISSN: 10995129     EISSN: 15322092     Source Type: Journal    
DOI: 10.1093/europace/eus210     Document Type: Review
Times cited : (33)

References (24)
  • 1
    • 67651052550 scopus 로고    scopus 로고
    • EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias: Developed in a partnership with the European Heart Rhythm Association (EHRA), a registered branch of the European Society of Cardiology (ESC), and the Heart Rhythm Society (HRS); In collaboration with the American College of Cardiology (ACC) and the American Heart Association (AHA)
    • Aliot EM, Stevenson WG, Almendral-Garrote JM, Bogun F, Calkins CH, Delacretaz E et al. EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias: developed in a partnership with the European Heart Rhythm Association (EHRA), a registered branch of the European Society of Cardiology (ESC), and the Heart Rhythm Society (HRS); in collaboration with the American College of Cardiology (ACC) and the American Heart Association (AHA). Europace 2009;11:771-817.
    • (2009) Europace , vol.11 , pp. 771-817
    • Aliot, E.M.1    Stevenson, W.G.2    Almendral-Garrote, J.M.3    Bogun, F.4    Calkins, C.H.5    Delacretaz, E.6
  • 2
    • 0032575360 scopus 로고    scopus 로고
    • Radiofrequency catheter ablation of ventricular tachycardia after myocardial infarction
    • Stevenson WG, Friedman PL, Kocovic D, Sager PT, Saxon LA, Pavri B. Radiofre-quency catheter ablation of ventricular tachycardia after myocardial infarction. Circulation 1998;98:308-14. (Pubitemid 28348052)
    • (1998) Circulation , vol.98 , Issue.4 , pp. 308-314
    • Stevenson, W.G.1    Friedman, P.L.2    Kocovic, D.3    Sager, P.T.4    Saxon, L.A.5    Pavri, B.6
  • 3
    • 0031845792 scopus 로고    scopus 로고
    • Efficacy of radiofrequency catheter ablation for ventricular tachycardia in healed myocardial infarction
    • DOI 10.1016/S0002-9149(98)00353-1, PII S0002914998003531
    • Callans DJ, Zado E, Sarter BH, Schwartzman D, Gottlieb CD, Marchlinski FE. Efficacy of radiofrequency catheter ablation for ventricular tachycardia in healed myocardial infarction. Am J Cardiol 1998;82:429-32. (Pubitemid 28389939)
    • (1998) American Journal of Cardiology , vol.82 , Issue.4 , pp. 429-432
    • Callans, D.J.1    Zado, E.2    Sarter, B.H.3    Schwartzman, D.4    Gottlieb, C.D.5    Marchlinski, F.E.6
  • 4
    • 80053046361 scopus 로고    scopus 로고
    • Activation and entrainment mapping of hemodynamically unstable ventricular tachycardia using a percutaneous left ventricular assist device
    • Miller MA, Dukkipati SR, Mittnacht AJ, Chinitz JS, Belliveau L, Koruth JS et al. Activation and entrainment mapping of hemodynamically unstable ventricular tachycardia using a percutaneous left ventricular assist device. J Am Coll Cardiol 2011;58: 1363-71.
    • (2011) J Am Coll Cardiol , vol.58 , pp. 1363-1371
    • Miller, M.A.1    Dukkipati, S.R.2    Mittnacht, A.J.3    Chinitz, J.S.4    Belliveau, L.5    Koruth, J.S.6
  • 5
    • 0027395909 scopus 로고
    • Radiofrequency catheter ablation of ventricular tachycardia in patients with coronary artery disease
    • Morady F, Harvey M, Kalbfleisch SJ, el-Atassi R, Calkins H, Langberg JJ. Radiofre-quency catheter ablation of ventricular tachycardia in patients with coronary artery disease. Circulation 1993;87:363-72. (Pubitemid 23040904)
    • (1993) Circulation , vol.87 , Issue.2 , pp. 363-372
    • Morady, F.1    Harvey, M.2    Kalbfleisch, S.J.3    El-Atassi, R.4    Calkins, H.5    Langberg, J.J.6
  • 6
    • 4043147092 scopus 로고    scopus 로고
    • Identification of the ventricular tachycardia isthmus after infarction by pace mapping
    • DOI 10.1161/01.CIR.0000138107.11518.AF
    • Brunckhorst CB, Delacretaz E, Soejima K, Maisel WH, Friedman PL, Stevenson WG. Identification of the ventricular tachycardia isthmus after infarction by pace mapping. Circulation 2004;110:652-9. (Pubitemid 39056262)
    • (2004) Circulation , vol.110 , Issue.6 , pp. 652-659
    • Brunckhorst, C.B.1    Delacretaz, E.2    Soejima, K.3    Maisel, W.H.4    Friedman, P.L.5    Stevenson, W.G.6
  • 8
    • 33646009476 scopus 로고    scopus 로고
    • Anatomic characterization of endocardial substrate for hemodynamically stable reentrant ventricular tachycardia: Identification of endocardial conducting channels
    • Hsia HH, Lin D, Sauer WH, Callans DJ, Marchlinski FE. Anatomic characterization of endocardial substrate for hemodynamically stable reentrant ventricular tachycardia: identification of endocardial conducting channels. Heart Rhythm 2006;3: 503-12.
    • (2006) Heart Rhythm , vol.3 , pp. 503-512
    • Hsia, H.H.1    Lin, D.2    Sauer, W.H.3    Callans, D.J.4    Marchlinski, F.E.5
  • 9
    • 0034696530 scopus 로고    scopus 로고
    • Linear ablation lesions for control of unmappable ventricular tachycardia in patients with ischemic and nonischemic cardiomyopathy
    • Marchlinski FE, Callans DJ, Gottlieb CD, Zado E. Linear ablation lesions for control of unmappable ventricular tachycardia in patients with ischemic and non-ischemic cardiomyopathy. Circulation 2000;101:1288-96. (Pubitemid 30158617)
    • (2000) Circulation , vol.101 , Issue.11 , pp. 1288-1296
    • Marchlinski, F.E.1    Callans, D.J.2    Gottlieb, C.D.3    Zado, E.4
  • 10
    • 0035822636 scopus 로고    scopus 로고
    • Catheter ablation in patients with multiple and unstable ventricular tachycardias after myocardial infarction: Short ablation lines guided by reentry circuit isthmuses and sinus rhythm mapping
    • Soejima K, Suzuki M, Maisel WH, Brunckhorst CB, Delacretaz E, Blier L et al. Catheter ablation in patients with multiple and unstable ventricular tachycardias after myocardial infarction: short ablation lines guided by reentry circuit isthmuses and sinus rhythm mapping. Circulation 2001;104:664-9. (Pubitemid 32738520)
    • (2001) Circulation , vol.104 , Issue.6 , pp. 664-669
    • Soejima, K.1    Suzuki, M.2    Maisel, W.H.3    Brunckhorst, C.B.4    Delacretaz, E.5    Blier, L.6    Tung, S.7    Khan, H.8    Stevenson, W.G.9
  • 11
    • 84860439066 scopus 로고    scopus 로고
    • Efficacy and safety of ventricular tachycardia ablation with mechanical circulatory support compared with substrate-based ablation techniques
    • Bunch TJ, Darby A, May HT, Mahapatra S. Efficacy and safety of ventricular tachycardia ablation with mechanical circulatory support compared with substrate-based ablation techniques. Europace 2011;14:709-14.
    • (2011) Europace , vol.14 , pp. 709-714
    • Bunch, T.J.1    Darby, A.2    May, H.T.3    Mahapatra, S.4
  • 12
    • 33845606794 scopus 로고    scopus 로고
    • Percutaneous endocardial and epicardial ablation of hypotensive ventricular tachycardia with percutaneous left ventricular assist in the electrophysiology laboratory
    • DOI 10.1111/j.1540-8167.2006.00619.x
    • Friedman PA, Munger TM, Torres N, Rihal C. Percutaneous endocardial and epi-cardial ablation of hypotensive ventricular tachycardia with percutaneous left ventricular assist in the electrophysiology laboratory. J Cardiovasc Electrophysiol 2007; 18:106-9. (Pubitemid 44952755)
    • (2007) Journal of Cardiovascular Electrophysiology , vol.18 , Issue.1 , pp. 106-109
    • Friedman, P.A.1    Munger, T.M.2    Torres, N.3    Rihal, C.4
  • 14
    • 77950280781 scopus 로고    scopus 로고
    • Use of the impella microaxial blood pump for ablation of hemodynamically unstable ventricular tachycardia
    • Abuissa H, Roshan J, Lim B, Asirvatham SJ. Use of the Impella microaxial blood pump for ablation of hemodynamically unstable ventricular tachycardia. J Cardiovasc Electrophysiol 2010;21:458-61.
    • (2010) J Cardiovasc Electrophysiol , vol.21 , pp. 458-461
    • Abuissa, H.1    Roshan, J.2    Lim, B.3    Asirvatham, S.J.4
  • 15
    • 70849087656 scopus 로고    scopus 로고
    • Percutaneous cardiopulmonary support for catheter ablation of unstable ventricular arrhythmias in high-risk patients
    • Carbucicchio C, Della Bella P, Fassini G, Trevisi N, Riva S, Giraldi F et al. Percutaneous cardiopulmonary support for catheter ablation of unstable ventricular arrhythmias in high-risk patients. Herz 2009;34:545-52.
    • (2009) Herz , vol.34 , pp. 545-552
    • Carbucicchio, C.1    Della Bella, P.2    Fassini, G.3    Trevisi, N.4    Riva, S.5    Giraldi, F.6
  • 16
    • 77952581913 scopus 로고    scopus 로고
    • Percutaneous left ventricular assist devices: Clinical uses, future applications, and anesthetic considerations
    • Pulido JN, Park SJ, Rihal CS. Percutaneous left ventricular assist devices: clinical uses, future applications, and anesthetic considerations. J Cardiothorac Vasc Anesth 2010;24:478-86.
    • (2010) J Cardiothorac Vasc Anesth , vol.24 , pp. 478-486
    • Pulido, J.N.1    Park, S.J.2    Rihal, C.S.3
  • 17
    • 70649104685 scopus 로고    scopus 로고
    • Percutaneous left ventricular support devices
    • Sarkar K, Kini AS. Percutaneous left ventricular support devices. Cardiol Clin 2010; 28:169-84.
    • (2010) Cardiol Clin , vol.28 , pp. 169-184
    • Sarkar, K.1    Kini, A.S.2
  • 21
  • 22
    • 77956494842 scopus 로고    scopus 로고
    • Noninvasive cerebral oximetry: Is there light at the end of the tunnel?
    • Highton D, Elwell C, Smith M. Noninvasive cerebral oximetry: is there light at the end of the tunnel? Curr Opin Anaesthesiol 2010;23:576-81.
    • (2010) Curr Opin Anaesthesiol , vol.23 , pp. 576-581
    • Highton, D.1    Elwell, C.2    Smith, M.3
  • 23
    • 77449084588 scopus 로고    scopus 로고
    • Near-infrared spectroscopy as an index of brain and tissue oxygenation
    • Murkin JM, Arango M. Near-infrared spectroscopy as an index of brain and tissue oxygenation. Br J Anaesth 2009;103(Suppl. 1):i3-13.
    • (2009) Br J Anaesth , vol.103 , Issue.SUPPL. 1
    • Murkin, J.M.1    Arango, M.2
  • 24
    • 84862285795 scopus 로고    scopus 로고
    • Changes in hemodynamic parameters and cerebral saturation during supraventricular tachycardia
    • Hershenson JA, Ro PS, Miao Y, Tobias JD, Olshove V, Naguib AN. Changes in hemodynamic parameters and cerebral saturation during supraventricular tachycardia. Pediatr Cardiol 2011;33:286-9.
    • (2011) Pediatr Cardiol , vol.33 , pp. 286-289
    • Hershenson, J.A.1    Ro, P.S.2    Miao, Y.3    Tobias, J.D.4    Olshove, V.5    Naguib, A.N.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.