메뉴 건너뛰기




Volumn 36, Issue 2, 2012, Pages 203-216

Transducer-based comparisons of the prosthetic feet used by transtibial amputees for different walking activities: A pilot study

Author keywords

Amputee; loading response patterns; prosthetic feet; transducer; transtibial; walking activities

Indexed keywords

ADULT; ARTICLE; CASE REPORT; DATA ANALYSIS; DISABLED PERSON; FEET PROSTHESIS; FEMALE; FOOT; FORCE; HUMAN; LEG AMPUTATION; LEG PROSTHESIS; MALE; PHYSICAL ACTIVITY; PILOT STUDY; PRESSURE TRANSDUCER; WALKING; WALKING SPEED; WEIGHT; WIRELESS COMMUNICATION;

EID: 84864440600     PISSN: 03093646     EISSN: 17461553     Source Type: Journal    
DOI: 10.1177/0309364612436408     Document Type: Article
Times cited : (25)

References (20)
  • 1
    • 0023388917 scopus 로고
    • Least-squares matrix correlations between stump stresses and prosthesis loads for below-knee amputees
    • Winarski DJ, Pearson JR. Least-squares matrix correlations between stump stresses and prosthesis loads for below-knee amputees. Trans ASME J Biomech Eng. 1987 ; 109: 238-246 (Pubitemid 17633604)
    • (1987) Journal of Biomechanical Engineering , vol.109 , Issue.3 , pp. 238-246
    • Winarski, D.J.1    Pearson, J.R.2
  • 2
    • 70349335356 scopus 로고    scopus 로고
    • Loading applied on prosthetic knee of transfemoral amputee: Comparison of inverse dynamics and direct measurements
    • Dumas R, Cheze L, Frossard L. Loading applied on prosthetic knee of transfemoral amputee: comparison of inverse dynamics and direct measurements. Gait Posture. 2000 ; 30: 560-562
    • (2000) Gait Posture , vol.30 , pp. 560-562
    • Dumas, R.1    Cheze, L.2    Frossard, L.3
  • 3
    • 0242592161 scopus 로고    scopus 로고
    • Development and preliminary testing of a device for the direct measurement of forces and moments in the prosthetic limb of transfemoral amputees during activities of daily living
    • Frossard L, Beck J, Dillon M, Evans J. Development and preliminary testing of a device for the direct measurement of forces and moments in the prosthetic limb of transfemoral amputees during activities of daily living. J Prosthet Orthot. 2003 ; 15 (4). 135-142
    • (2003) J Prosthet Orthot , vol.15 , Issue.4 , pp. 135-142
    • Frossard, L.1    Beck, J.2    Dillon, M.3    Evans, J.4
  • 4
    • 74849093657 scopus 로고    scopus 로고
    • Apparatus for monitoring load bearing rehabilitation exercises of a transfemoral amputee fitted with an osseointegrted fixation: A proof-of-concept study
    • Frossard L, Gow DL, Hagberg K, et al. Apparatus for monitoring load bearing rehabilitation exercises of a transfemoral amputee fitted with an osseointegrted fixation: a proof-of-concept study. Gait Posture. 2010 ; 31 (2). 223-228
    • (2010) Gait Posture , vol.31 , Issue.2 , pp. 223-228
    • Frossard, L.1    Gow, D.L.2    Hagberg, K.3
  • 5
    • 75149123433 scopus 로고    scopus 로고
    • Functional outcome of transfemoral amputees fitted with an osseointegrated fixation: Temporal gait characteristics
    • Frossard L, Hagberg K, Haggstrom E, Gow DL, Branemark R, Pearcy M. Functional outcome of transfemoral amputees fitted with an osseointegrated fixation: temporal gait characteristics. J Prosthet Orthot. 2010 ; 22 (1). 11-20
    • (2010) J Prosthet Orthot , vol.22 , Issue.1 , pp. 11-20
    • Frossard, L.1    Hagberg, K.2    Haggstrom, E.3    Gow, D.L.4    Branemark, R.5    Pearcy, M.6
  • 6
    • 77749279789 scopus 로고    scopus 로고
    • Load on an osseointegrated fixation of a transfemoral amputee during a fall: Loading, descent, impact and recovery analysis
    • Frossard LA, Tranberg R, Haggstrom E, et al. Load on an osseointegrated fixation of a transfemoral amputee during a fall: loading, descent, impact and recovery analysis. Prosthet Orthot Int. 2010 ; 34 (1). 85-97
    • (2010) Prosthet Orthot Int , vol.34 , Issue.1 , pp. 85-97
    • Frossard, L.A.1    Tranberg, R.2    Haggstrom, E.3
  • 7
    • 82255166841 scopus 로고    scopus 로고
    • Dynamic input to determine hip joint moments, power and work on the prosthetic limb of transfemoral amputees: Ground reaction vs knee reaction
    • Frossard L, Cheze L, Dumas R. Dynamic input to determine hip joint moments, power and work on the prosthetic limb of transfemoral amputees: ground reaction vs knee reaction. Prosthet Orthot Int. 2011 ; 35 (2). 140-149
    • (2011) Prosthet Orthot Int , vol.35 , Issue.2 , pp. 140-149
    • Frossard, L.1    Cheze, L.2    Dumas, R.3
  • 8
    • 34249315391 scopus 로고    scopus 로고
    • Kinetics of transfemoral amputees with osseointegrated fixation performing common activities of daily living
    • DOI 10.1016/j.clinbiomech.2007.02.005, PII S0268003307000393
    • Lee WCC, Frossard LA, Hagberg K, et al. Kinetics of transfemoral amputees with osseointegrated fixation performing common activities of daily living. Clin Biomech. 2007 ; 22: 665-673 (Pubitemid 46818624)
    • (2007) Clinical Biomechanics , vol.22 , Issue.6 , pp. 665-673
    • Lee, W.C.C.1    Frossard, L.A.2    Hagberg, K.3    Haggstrom, E.4    Branemark, R.5    Evans, J.H.6    Pearcy, M.J.7
  • 9
    • 50249188355 scopus 로고    scopus 로고
    • Magnitude and variability of loading on the osseointegrated implant of transfemoral amputees during walking
    • Lee WC, Frossard LA, Hagberg K, et al. Magnitude and variability of loading on the osseointegrated implant of transfemoral amputees during walking. Med Eng Phys. 2008 ; 30 (7). 825-833
    • (2008) Med Eng Phys , vol.30 , Issue.7 , pp. 825-833
    • Lee, W.C.1    Frossard, L.A.2    Hagberg, K.3
  • 10
    • 56249091032 scopus 로고    scopus 로고
    • FE stress analysis of the interface between the bone of an osseotintegrated implant for amputees- implications to refine the rehabilitation program
    • Lee WC, Doocey JM, Branemark R, et al. FE stress analysis of the interface between the bone of an osseotintegrated implant for amputees- implications to refine the rehabilitation program. Clin Biomech. 2008 ; 23 (10). 1243-1250
    • (2008) Clin Biomech , vol.23 , Issue.10 , pp. 1243-1250
    • Lee, W.C.1    Doocey, J.M.2    Branemark, R.3
  • 11
    • 70349335356 scopus 로고    scopus 로고
    • Loading applied on prosthetic knee of transfemoral amputee: Comparison of inverse dynamics and direct measurements
    • Dumas RL, Cheze L, Frossard L. Loading applied on prosthetic knee of transfemoral amputee: Comparison of inverse dynamics and direct measurements. Gait Posture. 2009 ; 30 (4). 560-562
    • (2009) Gait Posture , vol.30 , Issue.4 , pp. 560-562
    • Dumas, R.L.1    Cheze, L.2    Frossard, L.3
  • 13
    • 79955135259 scopus 로고    scopus 로고
    • Biomechanics and physiological parameters during gait in lower- limb amputees: A systematic review
    • Sagawa Y, Turcot K, Armand S, Thevenon A, Vuillerme N, Watelain E. Biomechanics and physiological parameters during gait in lower- limb amputees: A systematic review. Gait Posture. 2011 ; 33 (4). 511-526
    • (2011) Gait Posture , vol.33 , Issue.4 , pp. 511-526
    • Sagawa, Y.1    Turcot, K.2    Armand, S.3    Thevenon, A.4    Vuillerme, N.5    Watelain, E.6
  • 15
    • 27744530522 scopus 로고    scopus 로고
    • Clinical prescription and use of prosthetic foot and ankle mechanisms: A review of the literature. Prosthetic Foot/Ankle Mechanisms
    • Hafner BJ. Clinical prescription and use of prosthetic foot and ankle mechanisms: A review of the literature. Prosthetic Foot/Ankle Mechanisms. J Prosthet Orthot. 2005 ; 17 (4). S5 - S11
    • (2005) J Prosthet Orthot , vol.17 , Issue.4
    • Hafner, B.J.1
  • 16
    • 0036377554 scopus 로고    scopus 로고
    • Gait analysis in prosthetics: Opinions, ideas, and conclusions
    • Reitman JS, Postema K, Geertzen JHB. Gait analysis in prosthetics: opinions, ideas, and conclusions. Prosthet Orthot Int. 2002 ; 26 (1). 50-57
    • (2002) Prosthet Orthot Int , vol.26 , Issue.1 , pp. 50-57
    • Reitman, J.S.1    Postema, K.2    Geertzen, J.H.B.3
  • 17
    • 0035730625 scopus 로고    scopus 로고
    • Measurement of Socket Discomfort-Part II: Signal Detection
    • Neumann ES. Measurement of Socket Discomfort - Part II: Signal Detection. J Prosthet Orthot. 2001 ; 13 (4). 111-122 (Pubitemid 33687185)
    • (2001) Journal of Prosthetics and Orthotics , vol.13 , Issue.4 , pp. 111-122
    • Neumann, E.S.1
  • 18
    • 33750619553 scopus 로고    scopus 로고
    • Pressure distribution at the stump/socket interface in transtibial amputees during walking on stairs, slope and non-flat road
    • DOI 10.1016/j.clinbiomech.2006.06.004, PII S026800330600129X
    • Dou P, Xiaohong J, Suo S, Wang R, Zhang M. Pressure distribution at the stump/socket interface in transtibial amputees during walking on stairs, slope and non-flat road. Clin Biomech. 2006 ; 21: 1067-1073 (Pubitemid 44691987)
    • (2006) Clinical Biomechanics , vol.21 , Issue.10 , pp. 1067-1073
    • Dou, P.1    Jia, X.2    Suo, S.3    Wang, R.4    Zhang, M.5
  • 19
    • 70349863078 scopus 로고    scopus 로고
    • Pressure characteristics at the stump/socket interface in transtibial amputees using an adaptive prosthetic foot
    • Wolf SI, Alimusaj M, Fradet L, Siegel J, Bratz F. Pressure characteristics at the stump/socket interface in transtibial amputees using an adaptive prosthetic foot. Clin Biomech. 2009 ; 24 (10). 860-865
    • (2009) Clin Biomech , vol.24 , Issue.10 , pp. 860-865
    • Wolf, S.I.1    Alimusaj, M.2    Fradet, L.3    Siegel, J.4    Bratz, F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.