메뉴 건너뛰기




Volumn 67, Issue 9, 2012, Pages 833-839

Low radiation and low-contrast dose pulmonary CT angiography: Comparison of 80 kVp/60 ml and 100 kVp/80 ml protocols

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; CONTRAST NOISE RATIO; FEMALE; HUMAN; IMAGE QUALITY; LUNG ARTERY; LUNG EMBOLISM; MAJOR CLINICAL STUDY; MALE; NOISE; PRIORITY JOURNAL; PROSPECTIVE STUDY; RADIATION DOSE; SIGNAL NOISE RATIO;

EID: 84864413787     PISSN: 00099260     EISSN: 1365229X     Source Type: Journal    
DOI: 10.1016/j.crad.2011.11.016     Document Type: Article
Times cited : (47)

References (32)
  • 1
    • 35349026173 scopus 로고    scopus 로고
    • Management of suspected acute pulmonary embolism in the era of CT angiography: A statement from the Fleischner Society
    • DOI 10.1148/radiol.2452070397
    • M. Remy-Jardin, M. Pistolesi, and L.R. Goodman Management of suspected acute pulmonary embolism in the era of CT angiography: a statement from the Fleischner Society Radiology 245 2007 315 329 (Pubitemid 47612510)
    • (2007) Radiology , vol.245 , Issue.2 , pp. 315-329
    • Remy-Jardin, M.1    Pistolesi, M.2    Goodman, L.R.3    Gefter, W.B.4    Gottschalk, A.5    Mayo, J.R.6    Sostman, H.D.7
  • 6
    • 0036817672 scopus 로고    scopus 로고
    • How do radiographic techniques affect image quality and patient doses in CT?
    • DOI 10.1016/S0887-2171(02)90012-0
    • W. Huda, J.G. Ravenel, and E.M. Scalzetti How do radiographic techniques affect image quality and patient doses in CT? Semin Ultrasound CT MR 23 2002 411 422 (Pubitemid 35477571)
    • (2002) Seminars in Ultrasound CT and MRI , vol.23 , Issue.5 , pp. 411-422
    • Huda, W.1    Ravenel, J.G.2    Scalzetti, E.M.3
  • 7
    • 0033735138 scopus 로고    scopus 로고
    • Technique factors and image quality as functions of patient weight at abdominal CT
    • W. Huda, E.M. Scalzetti, and G. Levin Technique factors and image quality as functions of patient weight at abdominal CT Radiology 217 2000 430 435
    • (2000) Radiology , vol.217 , pp. 430-435
    • Huda, W.1    Scalzetti, E.M.2    Levin, G.3
  • 8
    • 33645562681 scopus 로고    scopus 로고
    • CT dose reduction and dose management tools: Overview of available options
    • DOI 10.1148/rg.262055138
    • C.H. McCollough, M.R. Bruesewitz, and J.M. Kofler Jr. CT dose reduction and dose management tools: overview of available options RadioGraphics 26 2006 503 512 (Pubitemid 43515321)
    • (2006) Radiographics , vol.26 , Issue.2 , pp. 503-512
    • McCollough, C.H.1    Bruesewitz, M.R.2    Kofler Jr., J.M.3
  • 9
    • 33846695725 scopus 로고    scopus 로고
    • CT angiography of pulmonary arteries to detect pulmonary embolism: Improvement of vascular enhancement with low kilovoltage settings
    • DOI 10.1148/radiol.2413040128
    • C. Schueller-Weidekamm, C.M. Schaefer-Prokop, and M. Weber CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings Radiology 241 2006 899 907 (Pubitemid 46190558)
    • (2006) Radiology , vol.241 , Issue.3 , pp. 899-907
    • Schueller-Weidekamm, C.1    Schaefer-Prokop, C.M.2    Weber, M.3    Herold, C.J.4    Prokop, M.5
  • 10
    • 61449268221 scopus 로고    scopus 로고
    • Minimizing contrast medium doses to diagnose pulmonary embolism with 80-kVp multidetector computed tomography in azotemic patients
    • F. Holmquist, K. Hansson, and F. Pasquariello Minimizing contrast medium doses to diagnose pulmonary embolism with 80-kVp multidetector computed tomography in azotemic patients Acta Radiol 50 2009 181 193
    • (2009) Acta Radiol , vol.50 , pp. 181-193
    • Holmquist, F.1    Hansson, K.2    Pasquariello, F.3
  • 11
    • 33645779286 scopus 로고    scopus 로고
    • Eighty-peak kilovoltage 16-channel multidetector computed tomography and reduced contrast-medium doses tailored to body weight to diagnose pulmonary embolism in azotaemic patients
    • F. Holmquist, and U. Nyman Eighty-peak kilovoltage 16-channel multidetector computed tomography and reduced contrast-medium doses tailored to body weight to diagnose pulmonary embolism in azotaemic patients Eur Radiol 16 2006 1165 1176
    • (2006) Eur Radiol , vol.16 , pp. 1165-1176
    • Holmquist, F.1    Nyman, U.2
  • 12
    • 59649088090 scopus 로고    scopus 로고
    • Patient exposure and image quality of low-dose pulmonary computed tomography angiography: Comparison of 100- and 80-kVp protocols
    • Z. Szucs-Farkas, L. Kurmann, and T. Strautz Patient exposure and image quality of low-dose pulmonary computed tomography angiography: comparison of 100- and 80-kVp protocols Invest Radiol 43 2008 871 876
    • (2008) Invest Radiol , vol.43 , pp. 871-876
    • Szucs-Farkas, Z.1    Kurmann, L.2    Strautz, T.3
  • 13
    • 0036068184 scopus 로고    scopus 로고
    • Overview of Prospective Investigation of Pulmonary Embolism Diagnosis II
    • DOI 10.1053/snuc.2002.124177
    • A. Gottschalk, P.D. Stein, and L.R. Goodman Overview of prospective investigation of pulmonary embolism diagnosis II Semin Nucl Med 32 2002 173 182 (Pubitemid 34803590)
    • (2002) Seminars in Nuclear Medicine , vol.32 , Issue.3 , pp. 173-182
    • Gottschalk, A.1    Stein, P.D.2    Goodman, L.R.3    Sostman, H.D.4
  • 14
    • 67650790313 scopus 로고    scopus 로고
    • Is body weight the most appropriate criterion to select patients eligible for low-dose pulmonary CT angiography? Analysis of objective and subjective image quality at 80 kVp in 100 patients
    • Z. Szucs-Farkas, T. Strautz, and M.A. Patak Is body weight the most appropriate criterion to select patients eligible for low-dose pulmonary CT angiography? Analysis of objective and subjective image quality at 80 kVp in 100 patients Eur Radiol 19 2009 1914 1922
    • (2009) Eur Radiol , vol.19 , pp. 1914-1922
    • Szucs-Farkas, Z.1    Strautz, T.2    Patak, M.A.3
  • 15
    • 23944513257 scopus 로고    scopus 로고
    • Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot
    • DOI 10.1118/1.1949787
    • T.G. Flohr, K. Stierstorfer, and S. Ulzheimer Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot Med Phys 32 2005 2536 2547 (Pubitemid 41197191)
    • (2005) Medical Physics , vol.32 , Issue.8 , pp. 2536-2547
    • Flohr, T.G.1    Stierstorfer, K.2    Ulzheimer, S.3    Bruder, H.4    Primak, A.N.5    McCollough, C.H.6
  • 18
    • 0034112337 scopus 로고    scopus 로고
    • Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax
    • P. Haage, T. Schmitz-Rode, and D. Hubner Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax AJR Am J Roentgenol 174 2000 1049 1053 (Pubitemid 30180001)
    • (2000) American Journal of Roentgenology , vol.174 , Issue.4 , pp. 1049-1053
    • Haage, P.1    Schmitz-Rode, T.2    Hubner, D.3    Piroth, W.4    Gunther, R.W.5
  • 20
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography - An increasing source of radiation exposure
    • DOI 10.1056/NEJMra072149
    • D.J. Brenner, and E.J. Hall Computed tomography - an increasing source of radiation exposure N Engl J Med 357 2007 2277 2284 (Pubitemid 350190758)
    • (2007) New England Journal of Medicine , vol.357 , Issue.22 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 21
    • 69349096036 scopus 로고    scopus 로고
    • Exposure to low-dose ionizing radiation from medical imaging procedures
    • R. Fazel, H.M. Krumholz, and Y. Wang Exposure to low-dose ionizing radiation from medical imaging procedures N Engl J Med 361 2009 849 857
    • (2009) N Engl J Med , vol.361 , pp. 849-857
    • Fazel, R.1    Krumholz, H.M.2    Wang, Y.3
  • 22
    • 73349087522 scopus 로고    scopus 로고
    • Detection of pulmonary emboli with CT angiography at reduced radiation exposure and contrast material volume: Comparison of 80 kVp and 120 kVp protocols in a matched cohort
    • Z. Szucs-Farkas, C. Schaller, and S. Bensler Detection of pulmonary emboli with CT angiography at reduced radiation exposure and contrast material volume: comparison of 80 kVp and 120 kVp protocols in a matched cohort Invest Radiol 44 2009 793 799
    • (2009) Invest Radiol , vol.44 , pp. 793-799
    • Szucs-Farkas, Z.1    Schaller, C.2    Bensler, S.3
  • 23
    • 15344342736 scopus 로고    scopus 로고
    • Improved vascular opacification in cerebral computed tomography angiography with 80 kVp
    • DOI 10.1097/01.rli.0000155281.32319.52
    • M.L. Bahner, A. Bengel, and G. Brix Improved vascular opacification in cerebral computed tomography angiography with 80 kVp Invest Radiol 40 2005 229 234 (Pubitemid 40393234)
    • (2005) Investigative Radiology , vol.40 , Issue.4 , pp. 229-234
    • Bahner, M.L.1    Bengel, A.2    Brix, G.3    Zuna, I.4    Kauczor, H.-U.5    Delorme, S.6
  • 24
    • 44449089365 scopus 로고    scopus 로고
    • Effect of x-ray tube parameters, iodine concentration, and patient size on image quality in pulmonary computed tomography angiography: A chest-phantom-study
    • DOI 10.1097/RLI.0b013e3181690042, PII 0000442420080600000006
    • Z. Szucs-Farkas, F.R. Verdun, and G. von Allmen Effect of x-ray tube parameters, iodine concentration, and patient size on image quality in pulmonary computed tomography angiography: a chest-phantom study Invest Radiol 43 2008 374 381 (Pubitemid 351769895)
    • (2008) Investigative Radiology , vol.43 , Issue.6 , pp. 374-381
    • Szucs-Farkas, Z.1    Verdun, F.R.2    Von Allmen, G.3    Mini, R.L.4    Vock, P.5
  • 25
    • 39749180841 scopus 로고    scopus 로고
    • Contrast enhancement in cardiovascular MDCT: Effect of body weight, height, body surface area, body mass index, and obesity
    • DOI 10.2214/AJR.07.2765
    • K.T. Bae, B.A. Seeck, and C.F. Hildebolt Contrast enhancement in cardiovascular MDCT: effect of body weight, height, body surface area, body mass index, and obesity AJR Am J Roentgenol 190 2008 777 784 (Pubitemid 351304525)
    • (2008) American Journal of Roentgenology , vol.190 , Issue.3 , pp. 777-784
    • Bae, K.T.1    Seeck, B.A.2    Hildebolt, C.F.3    Tao, C.4    Zhu, F.5    Kanematsu, M.6    Woodard, P.K.7
  • 26
    • 33846420993 scopus 로고    scopus 로고
    • Effect of patient weight and scanning duration on contrast enhancement during pulmonary multidetector CT angiography
    • DOI 10.1148/radiol.2422052132
    • K.T. Bae, C. Tao, and S. Gurel Effect of patient weight and scanning duration on contrast enhancement during pulmonary multidetector CT angiography Radiology 242 2007 582 589 (Pubitemid 46146211)
    • (2007) Radiology , vol.242 , Issue.2 , pp. 582-589
    • Bae, K.T.1    Tao, C.2    Gurel, S.3    Hong, C.4    Zhu, F.5    Gebke, T.A.6    Milite, M.7    Hildebolt, C.F.8
  • 27
    • 77953948373 scopus 로고    scopus 로고
    • Intravenous contrast medium administration and scan timing at CT: Considerations and approaches
    • K.T. Bae Intravenous contrast medium administration and scan timing at CT: considerations and approaches Radiology 256 2010 32 61
    • (2010) Radiology , vol.256 , pp. 32-61
    • Bae, K.T.1
  • 28
    • 25144443102 scopus 로고    scopus 로고
    • The indeterminate CT pulmonary angiogram: Imaging characteristics and patient clinical outcome
    • DOI 10.1148/radiol.2371041520
    • S.E. Jones, and C. Wittram The indeterminate CT pulmonary angiogram: imaging characteristics and patient clinical outcome Radiology 237 2005 329 337 (Pubitemid 41346183)
    • (2005) Radiology , vol.237 , Issue.1 , pp. 329-337
    • Jones, S.E.1    Wittram, C.2
  • 29
    • 77955626797 scopus 로고    scopus 로고
    • Contrast opacification using a reduced volume of iodinated contrast material and low peak kilovoltage in pulmonary CT angiography: Objective and subjective evaluation
    • A.R. Hunsaker, I.B. Oliva, and T. Cai Contrast opacification using a reduced volume of iodinated contrast material and low peak kilovoltage in pulmonary CT angiography: objective and subjective evaluation AJR Am J Roentgenol 195 2010 W118 W124
    • (2010) AJR Am J Roentgenol , vol.195
    • Hunsaker, A.R.1    Oliva, I.B.2    Cai, T.3
  • 30
    • 20744455342 scopus 로고    scopus 로고
    • Multi-detector row CT pulmonary angiography: Comparison of standard-dose and simulated low-dose techniques
    • DOI 10.1148/radiol.2361040190
    • D. Tack, V. De Maertelaer, and W. Petit Multi-detector row CT pulmonary angiography: comparison of standard-dose and simulated low-dose techniques Radiology 236 2005 318 325 (Pubitemid 40853329)
    • (2005) Radiology , vol.236 , Issue.1 , pp. 318-325
    • Tack, D.1    De Maertelaer, V.2    Petit, W.3    Scillia, P.4    Muller, P.5    Suess, C.6    Gevenois, P.A.7
  • 31
    • 0035902631 scopus 로고    scopus 로고
    • Excluding pulmonary embolism at the bedside without diagnostic imaging: Management of patients with suspected pulmonary embolism presenting to the emergency department by using a simple clinical model and D-dimer
    • P.S. Wells, D.R. Anderson, and M. Rodger Excluding pulmonary embolism at the bedside without diagnostic imaging: management of patients with suspected pulmonary embolism presenting to the emergency department by using a simple clinical model and d-dimer Ann Intern Med 135 2001 98 107 (Pubitemid 32661192)
    • (2001) Annals of Internal Medicine , vol.135 , Issue.2 , pp. 98-107
    • Wells, P.S.1    Anderson, D.R.2    Rodger, M.3    Stiell, I.4    Dreyer, J.F.5    Barnes, D.6    Forgie, M.7    Kovacs, G.8    Ward, J.9    Kovacs, M.J.10
  • 32
    • 77952469475 scopus 로고    scopus 로고
    • Enhanced visualization of lung vessels for diagnosis of pulmonary embolism using dual energy CT angiography
    • R. Krissak, T. Henzler, and M. Reichert Enhanced visualization of lung vessels for diagnosis of pulmonary embolism using dual energy CT angiography Invest Radiol 45 2010 341 346
    • (2010) Invest Radiol , vol.45 , pp. 341-346
    • Krissak, R.1    Henzler, T.2    Reichert, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.