Uncertainties in energy consumption introduced by building operations and weather for a medium-size office building

Author keywords

Building operations; EnergyPlus; Monte Carlo analysis; Uncertainties

Indexed keywords

BUILDING ENERGY CONSUMPTION; BUILDING ENVELOPES; BUILDING OPERATIONS; COMBINED EFFECT; CONFIDENCE LEVELS; DESIGN CONDITION; DESIGN FEATURES; ENERGY USE; ENERGYPLUS; GOOD PRACTICES; HVAC SYSTEM; IN-BUILDINGS; INPUT PARAMETER; LOG-NORMAL DISTRIBUTION; MONTE CARLO ANALYSIS; MULTIPLE PARAMETERS; OPERATIONAL FACTORS; OPERATIONAL PRACTICES; SIMULATION-BASED ANALYSIS; UNCERTAINTIES; UNCERTAINTY DISTRIBUTIONS;

EID: 84864402587     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2012.06.017     Document Type: Article
Times cited : (150)

References (19)
  • 2
    • 0035254162 scopus 로고    scopus 로고
    • Practical application of uncertainty analysis
    • DOI 10.1016/S0378-7788(00)00085-2
    • I. Macdonald, and P. Strachan Practical application of uncertainty analysis Energy and Buildings 33 3 2001 219 227 (Pubitemid 32029329)
    • (2001) Energy and Buildings , vol.33 , Issue.3 , pp. 219-227
    • MacDonald, I.1    Strachan, P.2
  • 3
    • 0036680411 scopus 로고    scopus 로고
    • Practical application of an uncertainty approach for hygrothermal building simulations-drying of an AAC flat roof
    • DOI 10.1016/S0360-1323(02)00047-1, PII S0360132302000471
    • A. Holm, and H. Kuenzel Practical application of an uncertainty approach for hygrothermal building simulations - drying of an AAC flat roof Building and Environment 37 8-9 2002 883 889 (Pubitemid 34789205)
    • (2002) Building and Environment , vol.37 , Issue.8-9 , pp. 883-889
    • Holm, A.H.1    Kuenzel, H.M.2
  • 4
    • 0036787951 scopus 로고    scopus 로고
    • Analysis of uncertainty in building design evaluations and its implications
    • S. de Wit, and G. Augenbroe Analysis of uncertainty in building design evaluations and its implications Energy and Buildings 34 9 2002 951 958
    • (2002) Energy and Buildings , vol.34 , Issue.9 , pp. 951-958
    • De Wit, S.1    Augenbroe, G.2
  • 5
    • 34250894308 scopus 로고    scopus 로고
    • Applying uncertainty considerations to energy conservation equations
    • DOI 10.1016/j.enbuild.2006.11.008, PII S0378778806002787
    • I. Macdonald, and J. Clarke Applying uncertainty considerations to energy conservation equations Energy and Buildings 39 9 2007 1019 1026 (Pubitemid 46990674)
    • (2007) Energy and Buildings , vol.39 , Issue.9 , pp. 1019-1026
    • Macdonald, I.A.1    Clarke, J.A.2
  • 6
    • 77950298208 scopus 로고    scopus 로고
    • Uncertainty in airflow rate calculations due to the use of surface-averaged pressure coefficients
    • D. Cóstola, B. Blocken, M. Ohba, and J. Hensen Uncertainty in airflow rate calculations due to the use of surface-averaged pressure coefficients Energy and Buildings 42 6 2010 881 888
    • (2010) Energy and Buildings , vol.42 , Issue.6 , pp. 881-888
    • Cóstola, D.1    Blocken, B.2    Ohba, M.3    Hensen, J.4
  • 7
    • 77954312607 scopus 로고    scopus 로고
    • Performance evaluation of passive cooling in office buildings based on uncertainty and sensitivity analysis
    • H. Breesch, and A. Janssens Performance evaluation of passive cooling in office buildings based on uncertainty and sensitivity analysis Solar Energy 84 8 2010 1453 1467
    • (2010) Solar Energy , vol.84 , Issue.8 , pp. 1453-1467
    • Breesch, H.1    Janssens, A.2
  • 9
    • 80054796916 scopus 로고    scopus 로고
    • Uncertainty analysis in building performance simulation for design support
    • C. Hopfe, and J. Hensen Uncertainty analysis in building performance simulation for design support Energy and Buildings 43 10 2011 2798 2805
    • (2011) Energy and Buildings , vol.43 , Issue.10 , pp. 2798-2805
    • Hopfe, C.1    Hensen, J.2
  • 10
    • 80053309659 scopus 로고    scopus 로고
    • Sensitivity analysis of building performance using probabilistic climate projections: A UK case study
    • W. Tian, P. de Wilde, and Uncertainty sensitivity analysis of building performance using probabilistic climate projections: a UK case study Automation in Construction 20 8 2011 1096 1109
    • (2011) Automation in Construction , vol.20 , Issue.8 , pp. 1096-1109
    • Tian, W.1    De Wilde, P.2    Uncertainty3
  • 11
    • 0001517888 scopus 로고    scopus 로고
    • Evaluation of HVAC system operational strategies for commercial buildings
    • PII S0196890496000398
    • M. Ardehali, and T. Smith Evaluation of HVAC system operational strategies for commercial buildings Energy Conversion and Management 38 3 1997 225 236 (Pubitemid 127416512)
    • (1997) Energy Conversion and Management , vol.38 , Issue.3 , pp. 225-236
    • Ardehali, M.M.1    Smith, T.F.2
  • 12
    • 31144462109 scopus 로고    scopus 로고
    • Dynamic simulation of energy management control functions for HVAC systems in buildings
    • DOI 10.1016/j.enconman.2005.06.011, PII S0196890405001664
    • W. Huang, M. Zaheeruddin, and S. Cho Dynamic simulation of energy management control functions for HVAC systems in buildings Energy Conversion and Management 47 7-8 2006 926 943 (Pubitemid 43132714)
    • (2006) Energy Conversion and Management , vol.47 , Issue.7-8 , pp. 926-943
    • Huang, W.Z.1    Zaheeruddin, M.2    Cho, S.H.3
  • 14
    • 84865640288 scopus 로고    scopus 로고
    • Commercial Reference Buildings
    • Commercial Reference Buildings, http://www1.eere.energy.gov/buildings/ commercial-initiative/reference-buildings. html, 2011.
    • (2011)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.