메뉴 건너뛰기




Volumn 26, Issue 8, 2012, Pages e102-e107

Central Head Perforation, or “Cut Through,” Caused by the Helical Blade of the Proximal Femoral Nail Antirotation

Author keywords

Cut through; Implant failure; Intramedullary nailing; PFNA; Proximal femur fracture

Indexed keywords

ADULT; AGED; ARTICLE; BONE NAIL; BONE RADIOGRAPHY; CANCELLOUS BONE; CLINICAL ASSESSMENT; FEMALE; FEMUR FRACTURE; FEMUR HEAD PROSTHESIS; FEMUR PERTROCHANTERIC FRACTURE; FRACTURE HEALING; FRACTURE NONUNION; HUMAN; INTRAMEDULLARY NAIL; JOINT MOBILITY; MAJOR CLINICAL STUDY; MALE; MECHANICAL TORSION; PERFORATION; PRIORITY JOURNAL; PROSTHESIS FAILURE; PROXIMAL FEMORAL NAIL ANTIROTATION; REOPERATION; RETROSPECTIVE STUDY; SURGICAL INFECTION; TOTAL HIP PROSTHESIS;

EID: 84864364451     PISSN: 08905339     EISSN: 15312291     Source Type: Journal    
DOI: 10.1097/BOT.0b013e31822c53c1     Document Type: Article
Times cited : (78)

References (23)
  • 1
    • 0034707104 scopus 로고    scopus 로고
    • Prevention of hip fracture in elderly people with use of a hip protectors
    • Kannus P, Parkkari J, Niemi S, et al. Prevention of hip fracture in elderly people with use of a hip protectors. N Engl J Med. 2000;343:1506-1513.
    • (2000) N Engl J Med , vol.343 , pp. 1506-1513
    • Kannus, P.1    Parkkari, J.2    Niemi, S.3
  • 2
    • 85060747589 scopus 로고
    • Gamma-Nagel Osteosynthesen per- und subtrochanterer Femurfrakturen
    • Friedel W, Colombo-Benkmann M, Dockter S, et al. Gamma-Nagel Osteosynthesen per- und subtrochanterer Femurfrakturen. Chirurg. 1994;65:953-963.
    • (1994) Chirurg , vol.65 , pp. 953-963
    • Friedel, W.1    Colombo-Benkmann, M.2    Dockter, S.3
  • 3
    • 84921430922 scopus 로고    scopus 로고
    • Parker MJ, Handoll HH, Bhonsle S, et al. Condylocephalic nails versus extramedullary implants for extracapsular hip fractures. Cochrane Database Syst Rev. 2000;(2); CD000338
    • Parker MJ, Handoll HH, Bhonsle S, et al. Condylocephalic nails versus extramedullary implants for extracapsular hip fractures. Cochrane Database Syst Rev. 2000;(2); CD000338.
  • 4
    • 84875526225 scopus 로고    scopus 로고
    • Parker MJ, Handoll HH, et al. Extramedullary fixation implants and external fixators for extracapsular hip fractures. Cochrane Database Syst Rev. 2002;(4); CD000339
    • Parker MJ, Handoll HH, et al. Extramedullary fixation implants and external fixators for extracapsular hip fractures. Cochrane Database Syst Rev. 2002;(4); CD000339.
  • 5
    • 0036181117 scopus 로고    scopus 로고
    • Migration of the lag screw within femoral head: an comparison of the intramedullary hip screw and the gamma asia-pacific nail
    • Watanabe Y, Minami G, Takeshita H, et al. Migration of the lag screw within femoral head: an comparison of the intramedullary hip screw and the gamma asia-pacific nail. J Orthop Trauma. 2002;16:104-107.
    • (2002) J Orthop Trauma , vol.16 , pp. 104-107
    • Watanabe, Y.1    Minami, G.2    Takeshita, H.3
  • 6
    • 0345451574 scopus 로고    scopus 로고
    • Failure of the femoral head fixation: a cadaveric analysis of lag screw cut-out with gamma locking nail and AO dynamic hip srew
    • Hayness RC, Poll RG, Miles AW, et al. Failure of the femoral head fixation: a cadaveric analysis of lag screw cut-out with gamma locking nail and AO dynamic hip srew. Injury. 1997;28:337-341.
    • (1997) Injury , vol.28 , pp. 337-341
    • Hayness, R.C.1    Poll, R.G.2    Miles, A.W.3
  • 7
    • 4043145938 scopus 로고    scopus 로고
    • Roth Ch, Hall H, et al. A laboratory model to evaluate cut out resistance of implants for pertrochanteric fracture fixation
    • Sommers MB, Roth Ch, Hall H, et al. A laboratory model to evaluate cut out resistance of implants for pertrochanteric fracture fixation. J Orthop Trauma. 2004;18:361-368.
    • (2004) J Orthop Trauma , vol.18 , pp. 361-368
    • Sommers, M.B.1
  • 8
    • 0041321380 scopus 로고    scopus 로고
    • Implant related complications in the treatment of unstable intertrochanteric fractures: meta-analysis of dynamic screw-plate versus dynamic intramedullary nail devices
    • Audigé L, Hanson B, Swiontkowski MF. Implant related complications in the treatment of unstable intertrochanteric fractures: meta-analysis of dynamic screw-plate versus dynamic intramedullary nail devices. Int Orthop. 2003;27:197-203.
    • (2003) Int Orthop , vol.27 , pp. 197-203
    • Audige, L.1    Hanson, B.2    Swiontkowski, M.F.3
  • 9
    • 17644364373 scopus 로고    scopus 로고
    • Trochanteric gamma nail and compression hip screw for trochanteric fractures: a randomized, prospective, comparative study in 210 elderly patients with a new design of the gamma nail
    • Utrilla AL, Reig JS, Munoz FM, et al. Trochanteric gamma nail and compression hip screw for trochanteric fractures: a randomized, prospective, comparative study in 210 elderly patients with a new design of the gamma nail. J Orthop Trauma. 2005;19:229-233.
    • (2005) J Orthop Trauma , vol.19 , pp. 229-233
    • Utrilla, A.L.1    Reig, J.S.2    Munoz, F.M.3
  • 10
    • 0039147632 scopus 로고    scopus 로고
    • The standard gamma nail: a critical analysis of 1,000 cases
    • Kakula C, Heinz T, Gaebler C, et al. The standard gamma nail: a critical analysis of 1,000 cases. J Trauma. 2001;51:77-83.
    • (2001) J Trauma , vol.51 , pp. 77-83
    • Kakula, C.1    Heinz, T.2    Gaebler, C.3
  • 11
    • 85026173290 scopus 로고    scopus 로고
    • PFNA [surgical technique]. Solothurn, Switzerland: Synthes GmbH; 2006
    • PFNA [surgical technique]. Solothurn, Switzerland: Synthes GmbH; 2006.
  • 12
    • 0028543841 scopus 로고
    • Komplikationen und Fehler bei der Anwendung des Gammanagels, Ursachen und Praevention
    • Heinz T, Vécsei V. Komplikationen und Fehler bei der Anwendung des Gammanagels, Ursachen und Praevention. Chirurg. 1994;65:943-952.
    • (1994) Chirurg , vol.65 , pp. 943-952
    • Heinz, T.1    Vecsei, V.2
  • 13
    • 20444449250 scopus 로고    scopus 로고
    • Comparative study of the treatment of pertrochanteric fracturestrochanteric gamma nail vs. proximal femoral nail
    • Megas P, Kaisidis A, Zouboulis P, et al. Comparative study of the treatment of pertrochanteric fractures—trochanteric gamma nail vs. proximal femoral nail. Z Orthop Ihre Grenzgeb. 2005; 143:252-257.
    • (2005) Z Orthop Ihre Grenzgeb , vol.143 , pp. 252-257
    • Megas, P.1    Kaisidis, A.2    Zouboulis, P.3
  • 14
    • 33748159153 scopus 로고    scopus 로고
    • Lee j, et al. helical blade versus sliding hip screw for treatment of unstable intertrochanteric hip fractures: A biomechanical evaluation
    • Strauss E, Frank J, Lee J, et al. Helical blade versus sliding hip screw for treatment of unstable intertrochanteric hip fractures: a biomechanical evaluation, Injury. 2006;37:984-989.
    • (2006) Injury , vol.37 , pp. 984-989
    • Strauss, E.1    Frank, J.2
  • 15
    • 0025034792 scopus 로고
    • Intertrochanteris femoral fractures, mechanical failures after internal fixation
    • Davis TR, Sher JL, Horsman A, et al. Intertrochanteris femoral fractures, mechanical failures after internal fixation. J Bone Joint Surg Br. 1990; 72B:26-31.
    • (1990) J Bone Joint Surg Br , vol.72B , pp. 26-31
    • Davis, T.R.1    Sher, J.L.2    Horsman, A.3
  • 16
    • 0029012764 scopus 로고
    • Lindskog dm, et al. the value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip
    • Baumgaertner MR, Curtin SL, Lindskog DM, et al. The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am. 1995;77-7:1058-1064.
    • (1995) J Bone Joint Surg Am , vol.77-7 , pp. 1058-1064
    • Baumgaertner, M.R.1    Curtin, S.L.2
  • 17
    • 0030720275 scopus 로고    scopus 로고
    • Awareness of the tip-apex distance reduces failure of the fixation of trochanteric fractures of the hip
    • Baumgaertner MR, et al. Awareness of the tip-apex distance reduces failure of the fixation of trochanteric fractures of the hip. J Bone Joint Surg Br. 1997;79B:969-971.
    • (1997) J Bone Joint Surg Br , vol.79B , pp. 969-971
    • Baumgaertner, M.R.1
  • 18
    • 1642463504 scopus 로고    scopus 로고
    • Treatment of unstable trochanteric fractures, randomised comparison of the gamma nail and the proximal femoral nail
    • Schipper IB, Steyerberg EW, Castelein RM, et al. Treatment of unstable trochanteric fractures, randomised comparison of the gamma nail and the proximal femoral nail. J Bone Joint Surg Br. 2004;86B:86-94.
    • (2004) J Bone Joint Surg Br , vol.86B , pp. 86-94
    • Schipper, I.B.1    Steyerberg, E.W.2    Castelein, R.M.3
  • 19
    • 0031925810 scopus 로고    scopus 로고
    • Cutting-out of the lag screw after internal fixation with the Asiatic gamma nail
    • Kawaguchi S, Sawada K, Nabeta Y, et al. Cutting-out of the lag screw after internal fixation with the Asiatic gamma nail. Injury. 1998;29:47-53.
    • (1998) Injury , vol.29 , pp. 47-53
    • Kawaguchi, S.1    Sawada, K.2    Nabeta, Y.3
  • 20
    • 59049089233 scopus 로고    scopus 로고
    • Jockel Jens Arne, Babst Reto, et al. The PFNA proximal femur nail in treatment of unstable proximal femur fractures3 cases of postoperative perforatin of the helical blade into the hip joint
    • Brunner A, Jöckel Jens Arne, Babst Reto, et al. The PFNA proximal femur nail in treatment of unstable proximal femur fractures—3 cases of postoperative perforatin of the helical blade into the hip joint. J Orthop Trauma. 2008;22:731-736.
    • (2008) J Orthop Trauma , vol.22 , pp. 731-736
    • Brunner, A.1
  • 21
    • 47549119043 scopus 로고    scopus 로고
    • The new proximal femur nail antirotation (PFNA) in daily practice: results of a multicentre cilinical study
    • Simmermacher RKJ, Liungqvist J, Bail H, et al. The new proximal femur nail antirotation (PFNA) in daily practice: results of a multicentre cilinical study. Injury. 2008;39:932-939.
    • (2008) Injury , vol.39 , pp. 932-939
    • Simmermacher, R.K.J.1    Liungqvist, J.2    Bail, H.3
  • 22
    • 28744438421 scopus 로고    scopus 로고
    • Behandlungsergebnisse und Komplikationen nach PFN-Osteosynthese
    • Hohendorff B, Meyer P, Menezes D, et al. Behandlungsergebnisse und Komplikationen nach PFN-Osteosynthese. Unfallchirurg. 2005;108:938-946.
    • (2005) Unfallchirurg , vol.108 , pp. 938-946
    • Hohendorff, B.1    Meyer, P.2    Menezes, D.3
  • 23
    • 19244369914 scopus 로고    scopus 로고
    • Intra- und perioperative Komplikationen bei der Stabilisierung von per und subtrochantaren Femurfrakturen mittels PFN
    • Werner-Tutschku W, Lajtai G, Schmiedhuber G, et al. Intra- und perioperative Komplikationen bei der Stabilisierung von per und subtrochantären Femurfrakturen mittels PFN. Unfallchirurg. 2002;105:881-885.
    • (2002) Unfallchirurg , vol.105 , pp. 881-885
    • Werner-Tutschku, W.1    Lajtai, G.2    Schmiedhuber, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.