메뉴 건너뛰기




Volumn 44, Issue 1, 2012, Pages

Evidence-based used, Yet still controversial: The arterial filter

Author keywords

Arterial filter; Bubble dynamics; Cardiopulmonary bypass; Microemboli

Indexed keywords

ARTERIAL LINE FILTER; ARTICLE; BLOOD FILTER; BLOOD FILTRATION; BLOOD FLOW VELOCITY; CARDIOPULMONARY BYPASS; DEVICE SAFETY; EMBOLISM; EVIDENCE BASED MEDICINE; FILTER DESIGN; GASEOUS MICROEMBOLUS; MICROEMBOLISM; OXYGENATOR; SCREEN ARTERIAL LINE FILTER; HEMOFILTRATION; HUMAN; INSTRUMENTATION; MORTALITY; POSTOPERATIVE COMPLICATION; RISK ASSESSMENT; RISK FACTOR; TREATMENT OUTCOME;

EID: 84864299310     PISSN: 00221058     EISSN: 29698960     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (17)

References (33)
  • 1
    • 33746343009 scopus 로고    scopus 로고
    • An evidence-based review of the practice of cardiopulmonary bypass in adults: A focus on neurologic injury, glycemic control, hemodilution, and the inflammatory response
    • Shann KG, Likosky DS, Murkin JM, et al. An evidence-based review of the practice of cardiopulmonary bypass in adults: A focus on neurologic injury, glycemic control, hemodilution, and the inflammatory response. J Thorac Cardiovasc Surg. 2006;132:283-90.
    • (2006) J Thorac Cardiovasc Surg. , vol.132 , pp. 283-290
    • Shann, K.G.1    Likosky, D.S.2    Murkin, J.M.3
  • 2
    • 0023909718 scopus 로고
    • Blood gas control during cardiopulmonary bypass
    • Pearson DT. Blood gas control during cardiopulmonary bypass. Perfusion. 1988;3:113-33.
    • (1988) Perfusion. , vol.3 , pp. 113-133
    • Pearson, D.T.1
  • 3
    • 84970462611 scopus 로고
    • A clinical evaluation of the performance characteristics of one membrane and five bubble oxygenators: Gas transfer and gaseous microemboli production
    • Pearson DT, Holden MP, Poslad SJ, Murray A, Waterhouse PS. A clinical evaluation of the performance characteristics of one membrane and five bubble oxygenators: Gas transfer and gaseous microemboli production. Perfusion. 1986;1:15-27.
    • (1986) Perfusion. , vol.1 , pp. 15-27
    • Pearson, D.T.1    Holden, M.P.2    Poslad, S.J.3    Murray, A.4    Waterhouse, P.S.5
  • 5
    • 0023900465 scopus 로고
    • Evaluation of a range of arterial line filters: Part II
    • Gourlay T, Gibbons M, Taylor KM. Evaluation of a range of arterial line filters: Part II. Perfusion. 1988;3:29-35.
    • (1988) Perfusion. , vol.3 , pp. 29-35
    • Gourlay, T.1    Gibbons, M.2    Taylor, K.M.3
  • 6
    • 30044445874 scopus 로고    scopus 로고
    • Single crossclamp improves 6-month cognitive outcome in high-risk coronary bypass patients: The effect of reduced aortic manipulation
    • Hammon JW, Stump DA, Butterworth JF, et al. Single crossclamp improves 6-month cognitive outcome in high-risk coronary bypass patients: The effect of reduced aortic manipulation. J Thorac Cardiovasc Surg. 2006;131:114-21.
    • (2006) J Thorac Cardiovasc Surg. , vol.131 , pp. 114-121
    • Hammon, J.W.1    Stump, D.A.2    Butterworth, J.F.3
  • 7
    • 34548693000 scopus 로고    scopus 로고
    • Coronary artery bypass grafting with single cross-clamp results in fewer persistent neuropsychological deficits than multiple clamp or off-pump coronary artery bypass grafting
    • discussion 1178-9
    • Hammon JW, Stump DA, Butterworth JF, et al. Coronary artery bypass grafting with single cross-clamp results in fewer persistent neuropsychological deficits than multiple clamp or off-pump coronary artery bypass grafting. Ann Thorac Surg. 2007;84:1174-8; discussion 1178-9.
    • (2007) Ann Thorac Surg. , vol.84 , pp. 1174-1178
    • Hammon, J.W.1    Stump, D.A.2    Butterworth, J.F.3
  • 8
    • 79960160640 scopus 로고    scopus 로고
    • Cannula design reduces particulate and gaseous emboli during cardiopulmonary bypass for coronary revascularization
    • Lata AL, Hammon JW, Deal DD, Stump DA, Kincaid EH, Kon ND. Cannula design reduces particulate and gaseous emboli during cardiopulmonary bypass for coronary revascularization. Perfusion. 2011;26:239-44.
    • (2011) Perfusion. , vol.26 , pp. 239-244
    • Lata, A.L.1    Hammon, J.W.2    Deal, D.D.3    Stump, D.A.4    Kincaid, E.H.5    Kon, N.D.6
  • 9
    • 39649106348 scopus 로고    scopus 로고
    • Cannulation of the noncalcified aorta generates particles of microembolic nature: An experimental study using pig aorta
    • Hedberg M, Funck B, Engstrom KG. Cannulation of the noncalcified aorta generates particles of microembolic nature: An experimental study using pig aorta. J Card Surg. 2008;23:39-43.
    • (2008) J Card Surg. , vol.23 , pp. 39-43
    • Hedberg, M.1    Funck, B.2    Engstrom, K.G.3
  • 10
    • 0036090385 scopus 로고    scopus 로고
    • Limitation of thrombin generation, platelet activation, and inflammation by elimination of cardiotomy suction in patients undergoing coronary artery bypass grafting treated with heparin-bonded circuits
    • Aldea GS, Soltow LO, Chandler WL, et al. Limitation of thrombin generation, platelet activation, and inflammation by elimination of cardiotomy suction in patients undergoing coronary artery bypass grafting treated with heparin-bonded circuits. J Thorac Cardiovasc Surg. 2002;123:742-55.
    • (2002) J Thorac Cardiovasc Surg. , vol.123 , pp. 742-755
    • Aldea, G.S.1    Soltow, L.O.2    Chandler, W.L.3
  • 11
    • 0033790341 scopus 로고    scopus 로고
    • Processing scavenged blood with a cell saver reduces cerebral lipid microembolization
    • Kincaid EH, Jones TJ, Stump DA, et al. Processing scavenged blood with a cell saver reduces cerebral lipid microembolization. Ann Thorac Surg. 2000;70:1296-300.
    • (2000) Ann Thorac Surg. , vol.70 , pp. 1296-1300
    • Kincaid, E.H.1    Jones, T.J.2    Stump, D.A.3
  • 12
    • 41949116693 scopus 로고    scopus 로고
    • Arterial line filters ranked for gaseous micro-emboli separation performance: An in vitro study
    • Riley JB. Arterial line filters ranked for gaseous micro-emboli separation performance: An in vitro study. J Extra Corpor Technol. 2008;40:21-6.
    • (2008) J Extra Corpor Technol. , vol.40 , pp. 21-26
    • Riley, J.B.1
  • 13
    • 84970314267 scopus 로고
    • Postbypass plasma surface tension and its role in bubble filtration
    • Hills BD, Kurusz M, Conti VR. Postbypass plasma surface tension and its role in bubble filtration. Perfusion. 1986;1:187-91.
    • (1986) Perfusion. , vol.1 , pp. 187-191
    • Hills, B.D.1    Kurusz, M.2    Conti, V.R.3
  • 14
    • 70349108407 scopus 로고    scopus 로고
    • Bubble tracking through computational fluid dynamics in arterial line filters for cardiopulmonary bypass
    • Fiore GB, Morbiducci U, Ponzini R, Redaelli A. Bubble tracking through computational fluid dynamics in arterial line filters for cardiopulmonary bypass. ASAIO J. 2009;55:438-44.
    • (2009) ASAIO J. , vol.55 , pp. 438-444
    • Fiore, G.B.1    Morbiducci, U.2    Ponzini, R.3    Redaelli, A.4
  • 15
    • 84970689943 scopus 로고
    • Performance characteristics of a new arterial line filter
    • Gourlay T, Gibbons M, Fleming J, Taylor KM. Performance characteristics of a new arterial line filter. Perfusion. 1987;2:19-26.
    • (1987) Perfusion. , vol.2 , pp. 19-26
    • Gourlay, T.1    Gibbons, M.2    Fleming, J.3    Taylor, K.M.4
  • 16
    • 16444363835 scopus 로고    scopus 로고
    • Quantification of blood flow through a clinical blood filter and kidney dialyzer using magnetic resonance imaging
    • Heese F, Robson P, Hall LD. Quantification of blood flow through a clinical blood filter and kidney dialyzer using magnetic resonance imaging. IEEE Sens J. 2005;5:273-6.
    • (2005) IEEE Sens J. , vol.5 , pp. 273-276
    • Heese, F.1    Robson, P.2    Hall, L.D.3
  • 17
    • 0030775565 scopus 로고    scopus 로고
    • Bubble generation and venous air filtration by hard-shell venous reservoirs: A comparative study
    • Mitchell SJ, Willcox T, Gorman DF. Bubble generation and venous air filtration by hard-shell venous reservoirs: A comparative study. Perfusion. 1997;12:325-33.
    • (1997) Perfusion. , vol.12 , pp. 325-333
    • Mitchell, S.J.1    Willcox, T.2    Gorman, D.F.3
  • 18
    • 68549132474 scopus 로고    scopus 로고
    • Post-arterial filter gaseous microemboli activity of five integral cardiotomy reservoirs during venting: An in vitro study
    • Myers GJ, Voorhees C, Haynes R, Eke B. Post-arterial filter gaseous microemboli activity of five integral cardiotomy reservoirs during venting: An in vitro study. J Extra Corpor Technol. 2009;41:20-7.
    • (2009) J Extra Corpor Technol. , vol.41 , pp. 20-27
    • Myers, G.J.1    Voorhees, C.2    Haynes, R.3    Eke, B.4
  • 19
    • 38449091286 scopus 로고    scopus 로고
    • Preventing gaseous microemboli during blood sampling and drug administration: An in vitro investigation
    • Myers GJ. Preventing gaseous microemboli during blood sampling and drug administration: An in vitro investigation. J Extra Corpor Technol. 2007;39:192-8.
    • (2007) J Extra Corpor Technol. , vol.39 , pp. 192-198
    • Myers, G.J.1
  • 20
    • 0031808588 scopus 로고    scopus 로고
    • Can an oxygenator design potentially contribute to air embolism in cardiopulmonary bypass? A novel method for the determination of the air removal capabilities of neonatal membrane oxygenators
    • De Somer F, Dierickx P, Dujardin D, Verdonck P, Van Nooten G. Can an oxygenator design potentially contribute to air embolism in cardiopulmonary bypass? A novel method for the determination of the air removal capabilities of neonatal membrane oxygenators. Perfusion. 1998;13:157-63.
    • (1998) Perfusion. , vol.13 , pp. 157-163
    • De Somer, F.1    Dierickx, P.2    Dujardin, D.3    Verdonck, P.4    Van Nooten, G.5
  • 22
    • 0031984688 scopus 로고    scopus 로고
    • Air trapping ability of the Spiral Gold membrane oxygenator: An ex vivo study
    • Mueller XM, Tevaearai HT, van Ness K, et al. Air trapping ability of the Spiral Gold membrane oxygenator: An ex vivo study. Perfusion. 1998;13:53-7.
    • (1998) Perfusion. , vol.13 , pp. 53-57
    • Mueller, X.M.1    Tevaearai, H.T.2    van Ness, K.3
  • 23
    • 0031009313 scopus 로고    scopus 로고
    • A comparison of gaseous emboli release in five membrane oxygenators
    • Beckley PD, Shinko PD, Sites JP. A comparison of gaseous emboli release in five membrane oxygenators. Perfusion. 1997;12:133-41.
    • (1997) Perfusion. , vol.12 , pp. 133-141
    • Beckley, P.D.1    Shinko, P.D.2    Sites, J.P.3
  • 25
    • 57549085563 scopus 로고    scopus 로고
    • A method to distinguish between gaseous and solid cerebral emboli in patients with prosthetic heart valves
    • Rodriguez RA, Nathan HJ, Ruel M, Rubens F, Dafoe D, Mesana T. A method to distinguish between gaseous and solid cerebral emboli in patients with prosthetic heart valves. Eur J Cardiothorac Surg. 2009;35:89-95.
    • (2009) Eur J Cardiothorac Surg. , vol.35 , pp. 89-95
    • Rodriguez, R.A.1    Nathan, H.J.2    Ruel, M.3    Rubens, F.4    Dafoe, D.5    Mesana, T.6
  • 27
    • 27244453756 scopus 로고    scopus 로고
    • Can Doppler time domain analysis of microembolic signals discriminate between gaseous and solid microemboli in patients with left ventricular assist device?
    • Thoennissen NH, Allroggen A, Dittrich R, et al. Can Doppler time domain analysis of microembolic signals discriminate between gaseous and solid microemboli in patients with left ventricular assist device? Neurol Res. 2005;27:780-4.
    • (2005) Neurol Res. , vol.27 , pp. 780-784
    • Thoennissen, N.H.1    Allroggen, A.2    Dittrich, R.3
  • 28
    • 3843112444 scopus 로고    scopus 로고
    • Solid or gaseous circulating brain emboli: Are they separable by transcranial ultrasound?
    • Darbellay GA, Duff R, Vesin JM, et al. Solid or gaseous circulating brain emboli: Are they separable by transcranial ultrasound? J Cereb Blood Flow Metab. 2004;24:860-8.
    • (2004) J Cereb Blood Flow Metab. , vol.24 , pp. 860-868
    • Darbellay, G.A.1    Duff, R.2    Vesin, J.M.3
  • 29
    • 0035181574 scopus 로고    scopus 로고
    • Investigation on the ability of an ultrasound bubble detector to deliver size measurements of gaseous bubbles in fluid lines by using a glass bead model
    • Eitschberger S, Henseler A, Krasenbrink B, Oedekoven B, Mottaghy K. Investigation on the ability of an ultrasound bubble detector to deliver size measurements of gaseous bubbles in fluid lines by using a glass bead model. ASAIO J. 2001;47:18-24.
    • (2001) ASAIO J. , vol.47 , pp. 18-24
    • Eitschberger, S.1    Henseler, A.2    Krasenbrink, B.3    Oedekoven, B.4    Mottaghy, K.5
  • 31
    • 0031864715 scopus 로고    scopus 로고
    • Cardiotomy suction: A major source of brain lipid emboli during cardiopulmonary bypass
    • Brooker RF, Brown WR, Moody DM, et al. Cardiotomy suction: A major source of brain lipid emboli during cardiopulmonary bypass. Ann Thorac Surg. 1998;65:1651-5.
    • (1998) Ann Thorac Surg. , vol.65 , pp. 1651-1655
    • Brooker, R.F.1    Brown, W.R.2    Moody, D.M.3
  • 32
    • 10544242198 scopus 로고    scopus 로고
    • Emboli from an extraluminal blood flow hollow fiber oxygenator with and without an arterial filter during cardiopulmonary bypass in a pig model
    • Dewanjee MK, Wu SM, Kapadvanjwala M, et al. Emboli from an extraluminal blood flow hollow fiber oxygenator with and without an arterial filter during cardiopulmonary bypass in a pig model. ASAIO J. 1996;42:1010-8.
    • (1996) ASAIO J. , vol.42 , pp. 1010-1018
    • Dewanjee, M.K.1    Wu, S.M.2    Kapadvanjwala, M.3
  • 33
    • 0018449058 scopus 로고
    • Thrombus formation and microaggregate removal during extracorporeal membrane oxygenation
    • Guidoin RG, Kenedi RM, Trudell L, Galleti P, Blais P. Thrombus formation and microaggregate removal during extracorporeal membrane oxygenation. J Biomed Mater Res. 1979;13:317-35.
    • (1979) J Biomed Mater Res. , vol.13 , pp. 317-335
    • Guidoin, R.G.1    Kenedi, R.M.2    Trudell, L.3    Galleti, P.4    Blais, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.