Cannula design reduces particulate and gaseous emboli during cardiopulmonary bypass for coronary revascularization

Author keywords

Aorta aortic; CABG surgery; Cardiopulmonary bypass (CPB); Embolism; Neurology neurologic injury

Indexed keywords

ADULT; ADULT RESPIRATORY DISTRESS SYNDROME; AGED; ARTICLE; CANNULA; CARDIOPULMONARY BYPASS; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; GAS EMBOLISM; HEART MUSCLE REVASCULARIZATION; HUMAN; MALE; MULTIPLE ORGAN FAILURE; OXYGEN TENSION; PARTICULATE MATTER; PRIORITY JOURNAL; STROKE; SURGICAL APPROACH; SURGICAL MORTALITY; SURGICAL PATIENT;

EID: 79960160640     PISSN: 02676591     EISSN: 1477111X     Source Type: Journal    
DOI: 10.1177/0267659110394905     Document Type: Article
Times cited : (12)

References (8)
  • 1
    • 34548693000 scopus 로고    scopus 로고
    • Coronary artery bypass grafting with single cross-clamp results in fewer persistent neuropsychological deficits than multiple clamp or off-pump coronary artery bypass grafting
    • DOI 10.1016/j.athoracsur.2007.04.100, PII S0003497507009502
    • Hammon JW, Stump DA, Butterwoth JF, et al. Coronary artery bypass grafting with single cross-clamp results in fewer persistent neuropsychological deficits than multiple clamp or off-pump coronary artery bypass grafting. Ann. Thorac Surg 2007; 84: 1174-1179 (Pubitemid 47417866)
    • (2007) Annals of Thoracic Surgery , vol.84 , Issue.4 , pp. 1174-1179
    • Hammon, J.W.1    Stump, D.A.2    Butterworth, J.F.3    Moody, D.M.4    Rorie, K.5    Deal, D.D.6    Kincaid, E.H.7    Oaks, T.E.8    Kon, N.D.9
  • 2
    • 0027484408 scopus 로고
    • Helical and retrograde secondary flow patterns in the aortic arch studied by three-directional magnetic resonance velocity mapping
    • Kilner PJ, Yang GZ, Mohiaddin RH, et al. Helical and retrograde secondary flow patterns in the aortic arch studied by three-directional magnetic resonance velocity mapping. Circulation 1993; 88: 2235-2247 (Pubitemid 23326104)
    • (1993) Circulation , vol.88 , Issue.5 , pp. 2235-2247
    • Kilner, P.J.1    Yang, G.Z.2    Mohiaddin, R.H.3    Firmin, D.N.4    Longmore, D.B.5
  • 4
    • 36448964491 scopus 로고    scopus 로고
    • Effect of cannula shape on aortic wall and flow turbulence: Hydrodynamic study during extracorporeal circulation in mock thoracic aorta
    • DOI 10.1111/j.1525-1594.2007.00481.x
    • Minakawa M, Fukuda I, Yamazaki J, Fukui K, Yanaoka H, Inamura T. Effect of cannula shape on aortic wall and flow turbulence: hydrodynamic study during extracorporeal circulation in mock thoracic aorta. Artif Organs 2007; 31(12): 880-886 (Pubitemid 350173647)
    • (2007) Artificial Organs , vol.31 , Issue.12 , pp. 880-886
    • Minakawa, M.1    Fukuda, I.2    Yamazaki, J.3    Fukui, K.4    Yanaoka, H.5    Inamura, T.6
  • 5
    • 41949134119 scopus 로고    scopus 로고
    • A comparison of the Hatteland CMD-10 versus the embolus detection and classification system
    • Stump DA, Vernon JC, Deal DD. A comparison of the Hatteland CMD-10 versus the embolus detection and classification system. Heart Surgery Forum 2004; 7: E617
    • (2004) Heart Surgery Forum , vol.7
    • Stump, D.A.1    Vernon, J.C.2    Deal, D.D.3
  • 7
    • 0036898954 scopus 로고    scopus 로고
    • Does vacuum-assisted venous drainage increase gaseous microemboli during cardiopulmonary bypass?
    • DOI 10.1016/S0003-4975(02)04081-X, PII S000349750204081X
    • Jones TJ, Deal DD, Vernon JC, Blackburn N, Stump DA. Does vacuum-assisted venous drainage increase gaseous microemboli during cardiopulmonary bypass? Ann Thorac Surg 2002; 74 (6): 2132-2137 (Pubitemid 35440892)
    • (2002) Annals of Thoracic Surgery , vol.74 , Issue.6 , pp. 2132-2137
    • Jones, T.J.1    Deal, D.D.2    Vernon, J.C.3    Blackburn, N.4    Stump, D.A.5
  • 8
    • 39049184851 scopus 로고    scopus 로고
    • In vitro evaluation of the air separation ability of four cardiovascular manufacturer extracorporeal circuit designs
    • Dickinson TA, Riley JB, Crowely JC, et al. In vitro evaluation of the air separation ability of four cardiovascular manufacturer extracorporeal circuit designs. J Extra Corpor Technology 2006; 38: 206-213 (Pubitemid 351506580)
    • (2006) Journal of Extra-Corporeal Technology , vol.38 , Issue.3 , pp. 206-213
    • Dickinson, T.A.1    Riley, J.B.2    Crowley, J.C.3    Zabetakis, P.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.