-
1
-
-
0033528550
-
Hip fractures in Finland between 1970 and 1997 and predictions for the future
-
DOI 10.1016/S0140-6736(98)04235-4
-
Kannus P, Niemi S, Parkkari J, Palvanen M, Vuori I, Järvinen M (1999) Hip fractures in Finland between 1970 and 1977 and predictions for the future. Lancet 353:802-805 (Pubitemid 29110406)
-
(1999)
Lancet
, vol.353
, Issue.9155
, pp. 802-805
-
-
Kannus, P.1
Niemi, S.2
Parkkari, J.3
Palvanen, M.4
Vuori, I.5
Jarvinen, M.6
-
2
-
-
0347003735
-
Optimum configuration of cannulated hip screws for the fixation of intracapsular hip fractures: A biomechanical study
-
DOI 10.1016/S0020-1383(03)00059-7
-
Selvan VT, Oakley MJ, Rangan A, Al-Lami MK (2004) Optimum configuration of cannulated hip screws for the fixation of intracapsular hip fractures: a biomechanical study. Injury 35:136-141 (Pubitemid 38084890)
-
(2004)
Injury
, vol.35
, Issue.2
, pp. 136-141
-
-
Selvan, V.T.1
Oakley, M.J.2
Rangan, A.3
Al-Lami, M.K.4
-
3
-
-
0037350504
-
Subtrochanteric fracture after cannulated screw fixation of femoral neck fractures: A report of four cases
-
DOI 10.1097/00005131-200303000-00013
-
Kloen P, Rubel IF, Lyden JP, Helfet DL (2003) Subtrochanteric fracture after cannulated screw fixation of femoral neck fractures: a case report of four cases. J Orthop Trauma 17:225-229 (Pubitemid 36395377)
-
(2003)
Journal of Orthopaedic Trauma
, vol.17
, Issue.3
, pp. 225-229
-
-
Kloen, P.1
Rubel, I.F.2
Lyden, J.P.3
Helfet, D.L.4
-
4
-
-
0029315622
-
Quality of reduction and cortical screw support in femoral neck fractures. An analysis of 72 fractures with a new computerized measuring method
-
Lindequist S, Tornkvist H (1995) Quality of reduction and cortical screw support in femoral neck fractures. An analysis of 72 fractures with a new computerized measuring method. J Orthop Trauma 9:215-221
-
(1995)
J Orthop Trauma
, vol.9
, pp. 215-221
-
-
Lindequist, S.1
Tornkvist, H.2
-
5
-
-
0011487765
-
Intracapsular femoral neck fractures: The importance of early reduction and stable osteosynthesis
-
Szita J, Cserhati P, Bosch U, Manninger J, Bodzay T, Fekete K (2002) Intracapsular femoral neck fractures: the importance of early reduction and stable osteosynthesis. Injury 33:41-46
-
(2002)
Injury
, vol.33
, pp. 41-46
-
-
Szita, J.1
Cserhati, P.2
Bosch, U.3
Manninger, J.4
Bodzay, T.5
Fekete, K.6
-
6
-
-
0031204509
-
Radiation exposure to the orthopaedic surgical team during fluoroscopy: "How far away is far enough?"
-
Mehlman CT, DiPasquale TG (1997) Radiation exposure to the orthopaedic surgical team during fluoroscopy: "how far away is far enough?". J Orthop Trauma 11:392-398 (Pubitemid 127728684)
-
(1997)
Journal of Orthopaedic Trauma
, vol.11
, Issue.6
, pp. 392-398
-
-
Mehlman, C.T.1
DiPasquale, T.G.2
-
7
-
-
0027195363
-
Exposure of the orthopaedic surgeon to radiation
-
Sanders R, Koval KJ, Di Pasquale T, Schmelling G, Stenzler S, Ross E (1993) Exposure of the orthopaedic surgeon to radiation. J Bone Joint Surg [Am] 75:326-330 (Pubitemid 23137935)
-
(1993)
Journal of Bone and Joint Surgery - Series A
, vol.75
, Issue.3
, pp. 326-330
-
-
Sanders, R.1
Koval, K.J.2
DiPasquale, T.3
Schmelling, G.4
Stenzler, S.5
Ross, E.6
-
8
-
-
35648996491
-
Three-dimensional fluoroscopy for evaluation of articular reduction and screw placement in calcaneal fractures
-
DOI 10.3113/FAI.2007.1165
-
Kendoff D, Citak M, Gardner MJ, Kfuri M Jr, Thumes B, Krettek C, Hüfner T (2007) Three-dimensional fluoroscopy for evaluation of articular reduction and screw placement in calcaneal fractures. Foot Ankle Int 28:1165-1171 (Pubitemid 350036898)
-
(2007)
Foot and Ankle International
, vol.28
, Issue.11
, pp. 1165-1171
-
-
Kendoff, D.1
Citak, M.2
Gardner, M.3
Kfuri Jr., M.4
Thumes, B.5
Krettek, C.6
Hufner, T.7
-
9
-
-
0034841683
-
3-D imaging with a mobile surgical image enhancement equipment (ISO-C-3D). Initial examples of fracture diagnosis of peripheral joints in comparison with spiral CT and conventional radiography
-
Kotsianos D, Rock C, Euler E, Wirth S, Linsenmaier U, Brandl R, Mutschler W, Pfeifer KJ (2001) 3-D imaging with a mobile surgical image enhancement equipment (ISO-C-3D). Initial examples of fracture diagnosis of peripheral joints in comparison with spiral CT and conventional radiography. Unfallchirurg 104:834-838
-
(2001)
Unfallchirurg
, vol.104
, pp. 834-838
-
-
Kotsianos, D.1
Rock, C.2
Euler, E.3
Wirth, S.4
Linsenmaier, U.5
Brandl, R.6
Mutschler, W.7
Pfeifer, K.J.8
-
10
-
-
0344825887
-
3D-gestützte navigierte implantation von pedikelschrauben an BWS und LWS
-
Wendl K, von Recum J, Wentzensen A, Grützner PA (2003) Iso-C 3D assisted navigated implantation of pedicle screws in thoracic lumbar vertebrae. Unfallchirurg 106:907-913 (Pubitemid 37444153)
-
(2003)
Unfallchirurg
, vol.106
, Issue.11
, pp. 907-913
-
-
Wendl, K.1
Von Recum, J.2
Wentzensen, A.3
Grutzner, P.A.4
-
11
-
-
4143115813
-
CT- und fluoroskopiebasierte navigation in der becken-chirurgie
-
Stöckle U, König B, Schaser K, Melcher I, Haas NP (2003) CT and fluoroscopy based navigation in pelvic surgery. Unfallchirurg 106:914-920 (Pubitemid 37444154)
-
(2003)
Unfallchirurg
, vol.106
, Issue.11
, pp. 914-920
-
-
Stockle, U.1
Konig, B.2
Schaser, K.3
Melcher, I.4
Haas, N.P.5
-
12
-
-
34247136630
-
Image guidance in pelvic and acetabular surgery-Expectations, success and limitations
-
DOI 10.1016/j.injury.2007.01.024, PII S0020138307000277, Pelvic and Acetabular Surgery
-
Stöckle U, Schaser K, König B (2007) Image guidance in pelvic and acetabular surgery - expectations, success and limitations. Injury 38:450-462 (Pubitemid 46584674)
-
(2007)
Injury
, vol.38
, Issue.4
, pp. 450-462
-
-
Stockle, U.1
Schaser, K.2
Konig, B.3
-
13
-
-
33846807507
-
Safety of computer-assisted surgery for cannulated hip screws
-
DOI 10.1097/01.blo.0000238815.40777.d2, PII 0000308620070200000037
-
Hamelinck HKM, Haagmans M, Snoeren MM (2006) Safety of computer-assisted surgery for cannulated hip screws. Clin Orthop Rel Res 455:241-245 (Pubitemid 46213738)
-
(2007)
Clinical Orthopaedics and Related Research
, Issue.455
, pp. 241-245
-
-
Hamelinck, H.K.M.1
Haagmans, M.2
Snoeren, M.M.3
Biert, J.4
Van Vugt, A.B.5
Frolke, J.P.M.6
-
14
-
-
27744576424
-
Computer-assisted guidewire insertion for hip fracture fixation
-
DOI 10.1097/01.bot.0000177106.30837.28
-
Mayman D, Vasarhelyi EM, Long W, Ellis RE, Rudan J, Pichora DR (2005) Computer-assisted guidewire insertion for hip fracture fixation. J Orthop Trauma 19:610-615 (Pubitemid 41598076)
-
(2005)
Journal of Orthopaedic Trauma
, vol.19
, Issue.9
, pp. 610-615
-
-
Mayman, D.1
Vasarhelyi, E.M.2
Long, W.3
Ellis, R.E.4
Rudan, J.5
Pichora, D.R.6
-
15
-
-
1542299012
-
Fluoroscopy-Based Surgical Navigation versus Fluoroscopic Guidance to Control Guide Wire Insertion for Osteosynthesis of Femoral Neck Fractures: An Experimental Study
-
DOI 10.1007/s00068-004-1267-2
-
Suhm N, Beck T, Zuna I, Marazzi C, Staedele H, Jacob AL, Messmer P, Regazzoni P (2004) Fluoroscopy-based surgical navigation versus fluoroscopic guidance to control guide wire insertion for osteosynthesis of femoral neck fractures. Eur J Trauma 1:23-28 (Pubitemid 38313495)
-
(2004)
European Journal of Trauma
, vol.30
, Issue.1
, pp. 23-28
-
-
Suhm, N.1
Beck, T.2
Zuna, I.3
Marazzi, C.4
Staedele, H.5
Jacob, A.L.6
Messmer, P.7
Regazzoni, P.8
-
16
-
-
78650957374
-
Evaluation of a fluoroscopy-based navigation system enabling a virtual radiation-free preview of X-ray images for placement of cannulated hip screws. A cadaver study
-
Mueller MC, Belei P, de la Fuente M, Strake M, Weber O, Burger C, Radermacher K, Wirtz DC (2011) Evaluation of a fluoroscopy-based navigation system enabling a virtual radiation-free preview of X-ray images for placement of cannulated hip screws. A cadaver study. Comp Aided Surg 16:22-31
-
(2011)
Comp Aided Surg
, vol.16
, pp. 22-31
-
-
Mueller, M.C.1
Belei, P.2
De La Fuente, M.3
Strake, M.4
Weber, O.5
Burger, C.6
Radermacher, K.7
Wirtz, D.C.8
-
17
-
-
18944374772
-
The complications of displaced intracapsular fractures of the hip. The effect of screw positioning and angulation on fracture healing
-
DOI 10.1302/0301-620X.87B5.15237
-
Gurusamy K, Parker MJ, Rowlands TK (2005) The complications of displaced intracapsular fractures of the hip: the effect of screw positioning and angulation on fracture healing. J Bone Joint Surg Br 87:632-634 (Pubitemid 40711634)
-
(2005)
Journal of Bone and Joint Surgery - Series B
, vol.87
, Issue.5
, pp. 632-634
-
-
Gurusamy, K.1
Parker, M.J.2
Rowlands, T.K.3
-
18
-
-
33746901218
-
Computerized navigation for the internal fixation of femoral neck fractures
-
DOI 10.2106/JBJS.E.00137
-
Liebergall M, Ben-David D, Weil Y, Peyser A, Mosheiff R (2006) Computerized navigation for the internal fixation of femoral neck fractures. J Bone Joint Surg [Am] 88:1748-1754 (Pubitemid 44200213)
-
(2006)
Journal of Bone and Joint Surgery - Series A
, vol.88
, Issue.8
, pp. 1748-1754
-
-
Liebergall, M.1
Ben-David, D.2
Weil, Y.3
Peyser, A.4
Mosheiff, R.5
-
19
-
-
33750300647
-
Eine neue doppelbohrbüchse zur navigierten schenkelhalsverschraubung: Entwicklung und evaluation
-
DOI 10.1007/s00113-006-1142-1
-
Kendoff D, Hüfner T, Citak M, Maier C, Wesemeier F, Pearle A, Krettek C (2006) A new parallel drill guide for navigating femoral neck screw placement. Development and evaluation. Unfallchirurg 109:875-880 (Pubitemid 44624512)
-
(2006)
Unfallchirurg
, vol.109
, Issue.10
, pp. 875-880
-
-
Kendoff, D.1
Hufner, T.2
Citak, M.3
Maier, C.4
Wesemeier, F.5
Pearle, A.6
Krettek, C.7
-
20
-
-
0036181955
-
Untersuchungen zur bildqualität, hochkontrastauflösung und dosis am stamm- und gliedmaenskelett mit einem neuen dedizierten CT-system (ISO-C-3D)
-
DOI 10.1055/s-2002-20107
-
Rock C, Kotsianos D, Linsenmaier U, Fischer T, Brandl R, Vill F, Wirth S, Kaltschmidt R, Euler E, Pfeifer KJ, Reiser M (2002) Studies on image quality, high contrast resolution and dose for the axial skeleton and limbs with a new, dedicated CT system (ISO-D-3D). Rofo 174:170-176 (Pubitemid 34177234)
-
(2002)
RoFo Fortschritte auf dem Gebiet der Rontgenstrahlen und der Bildgebenden Verfahren
, vol.174
, Issue.2
, pp. 170-176
-
-
Rock, C.1
Kotsianos, D.2
Linsenmaier, U.3
Fischer, T.4
Brandl, R.5
Vill, F.6
Wirth, S.7
Kaltschmidt, R.8
Euler, E.9
Pfeifer, K.J.10
Reiser, M.11
-
21
-
-
0025612507
-
Shielding of the patient's gonads during intramedullary interlocking femoral nailing
-
Kwong L, Johanson PH, Zinar DM, Lenihan MR, Herman MW (1990) Shielding of the patient's gonads during intramedullary interlocking femoral nailing. J Bone Joint Surg [Am] 72:1523-1526
-
(1990)
J Bone Joint Surg [Am]
, vol.72
, pp. 1523-1526
-
-
Kwong, L.1
Johanson, P.H.2
Zinar, D.M.3
Lenihan, M.R.4
Herman, M.W.5
-
22
-
-
33847266869
-
Experimental validation of noninvasive referencing in navigated procedures on long bones
-
DOI 10.1002/jor.20318
-
Kendoff D, Bogojevic A, Citak M, Citak M, Maier C, Maier G, Krettek C, Hüfner T (2007) Experimental validation of non-invasive referencing in navigated procedures on long bones. J Orthop Res 25:201-207 (Pubitemid 46344246)
-
(2007)
Journal of Orthopaedic Research
, vol.25
, Issue.2
, pp. 201-207
-
-
Kendoff, D.1
Bogojevic, A.2
Citak, M.3
Citak, M.4
Maier, C.5
Maier, G.6
Krettek, C.7
Hufner, T.8
|