메뉴 건너뛰기




Volumn 36, Issue 7, 2012, Pages 1463-1469

Three-dimensional computer-assisted navigation for the placement of cannulated hip screws. A pilot study

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ARTICLE; BONE SCREW; COMPUTER ASSISTED SURGERY; COMPUTER SYSTEM; DRILL; FEMUR NECK FRACTURE; FLUOROSCOPY; FRACTURE TREATMENT; GUIDE WIRE; HIP PROSTHESIS; OPERATION DURATION; PILOT STUDY; PRIORITY JOURNAL; THREE DIMENSIONAL IMAGING;

EID: 84864284686     PISSN: 03412695     EISSN: 14325195     Source Type: Journal    
DOI: 10.1007/s00264-012-1496-7     Document Type: Article
Times cited : (30)

References (22)
  • 1
    • 0033528550 scopus 로고    scopus 로고
    • Hip fractures in Finland between 1970 and 1997 and predictions for the future
    • DOI 10.1016/S0140-6736(98)04235-4
    • Kannus P, Niemi S, Parkkari J, Palvanen M, Vuori I, Järvinen M (1999) Hip fractures in Finland between 1970 and 1977 and predictions for the future. Lancet 353:802-805 (Pubitemid 29110406)
    • (1999) Lancet , vol.353 , Issue.9155 , pp. 802-805
    • Kannus, P.1    Niemi, S.2    Parkkari, J.3    Palvanen, M.4    Vuori, I.5    Jarvinen, M.6
  • 2
    • 0347003735 scopus 로고    scopus 로고
    • Optimum configuration of cannulated hip screws for the fixation of intracapsular hip fractures: A biomechanical study
    • DOI 10.1016/S0020-1383(03)00059-7
    • Selvan VT, Oakley MJ, Rangan A, Al-Lami MK (2004) Optimum configuration of cannulated hip screws for the fixation of intracapsular hip fractures: a biomechanical study. Injury 35:136-141 (Pubitemid 38084890)
    • (2004) Injury , vol.35 , Issue.2 , pp. 136-141
    • Selvan, V.T.1    Oakley, M.J.2    Rangan, A.3    Al-Lami, M.K.4
  • 3
    • 0037350504 scopus 로고    scopus 로고
    • Subtrochanteric fracture after cannulated screw fixation of femoral neck fractures: A report of four cases
    • DOI 10.1097/00005131-200303000-00013
    • Kloen P, Rubel IF, Lyden JP, Helfet DL (2003) Subtrochanteric fracture after cannulated screw fixation of femoral neck fractures: a case report of four cases. J Orthop Trauma 17:225-229 (Pubitemid 36395377)
    • (2003) Journal of Orthopaedic Trauma , vol.17 , Issue.3 , pp. 225-229
    • Kloen, P.1    Rubel, I.F.2    Lyden, J.P.3    Helfet, D.L.4
  • 4
    • 0029315622 scopus 로고
    • Quality of reduction and cortical screw support in femoral neck fractures. An analysis of 72 fractures with a new computerized measuring method
    • Lindequist S, Tornkvist H (1995) Quality of reduction and cortical screw support in femoral neck fractures. An analysis of 72 fractures with a new computerized measuring method. J Orthop Trauma 9:215-221
    • (1995) J Orthop Trauma , vol.9 , pp. 215-221
    • Lindequist, S.1    Tornkvist, H.2
  • 5
    • 0011487765 scopus 로고    scopus 로고
    • Intracapsular femoral neck fractures: The importance of early reduction and stable osteosynthesis
    • Szita J, Cserhati P, Bosch U, Manninger J, Bodzay T, Fekete K (2002) Intracapsular femoral neck fractures: the importance of early reduction and stable osteosynthesis. Injury 33:41-46
    • (2002) Injury , vol.33 , pp. 41-46
    • Szita, J.1    Cserhati, P.2    Bosch, U.3    Manninger, J.4    Bodzay, T.5    Fekete, K.6
  • 6
    • 0031204509 scopus 로고    scopus 로고
    • Radiation exposure to the orthopaedic surgical team during fluoroscopy: "How far away is far enough?"
    • Mehlman CT, DiPasquale TG (1997) Radiation exposure to the orthopaedic surgical team during fluoroscopy: "how far away is far enough?". J Orthop Trauma 11:392-398 (Pubitemid 127728684)
    • (1997) Journal of Orthopaedic Trauma , vol.11 , Issue.6 , pp. 392-398
    • Mehlman, C.T.1    DiPasquale, T.G.2
  • 8
    • 35648996491 scopus 로고    scopus 로고
    • Three-dimensional fluoroscopy for evaluation of articular reduction and screw placement in calcaneal fractures
    • DOI 10.3113/FAI.2007.1165
    • Kendoff D, Citak M, Gardner MJ, Kfuri M Jr, Thumes B, Krettek C, Hüfner T (2007) Three-dimensional fluoroscopy for evaluation of articular reduction and screw placement in calcaneal fractures. Foot Ankle Int 28:1165-1171 (Pubitemid 350036898)
    • (2007) Foot and Ankle International , vol.28 , Issue.11 , pp. 1165-1171
    • Kendoff, D.1    Citak, M.2    Gardner, M.3    Kfuri Jr., M.4    Thumes, B.5    Krettek, C.6    Hufner, T.7
  • 9
    • 0034841683 scopus 로고    scopus 로고
    • 3-D imaging with a mobile surgical image enhancement equipment (ISO-C-3D). Initial examples of fracture diagnosis of peripheral joints in comparison with spiral CT and conventional radiography
    • Kotsianos D, Rock C, Euler E, Wirth S, Linsenmaier U, Brandl R, Mutschler W, Pfeifer KJ (2001) 3-D imaging with a mobile surgical image enhancement equipment (ISO-C-3D). Initial examples of fracture diagnosis of peripheral joints in comparison with spiral CT and conventional radiography. Unfallchirurg 104:834-838
    • (2001) Unfallchirurg , vol.104 , pp. 834-838
    • Kotsianos, D.1    Rock, C.2    Euler, E.3    Wirth, S.4    Linsenmaier, U.5    Brandl, R.6    Mutschler, W.7    Pfeifer, K.J.8
  • 10
    • 0344825887 scopus 로고    scopus 로고
    • 3D-gestützte navigierte implantation von pedikelschrauben an BWS und LWS
    • Wendl K, von Recum J, Wentzensen A, Grützner PA (2003) Iso-C 3D assisted navigated implantation of pedicle screws in thoracic lumbar vertebrae. Unfallchirurg 106:907-913 (Pubitemid 37444153)
    • (2003) Unfallchirurg , vol.106 , Issue.11 , pp. 907-913
    • Wendl, K.1    Von Recum, J.2    Wentzensen, A.3    Grutzner, P.A.4
  • 11
    • 4143115813 scopus 로고    scopus 로고
    • CT- und fluoroskopiebasierte navigation in der becken-chirurgie
    • Stöckle U, König B, Schaser K, Melcher I, Haas NP (2003) CT and fluoroscopy based navigation in pelvic surgery. Unfallchirurg 106:914-920 (Pubitemid 37444154)
    • (2003) Unfallchirurg , vol.106 , Issue.11 , pp. 914-920
    • Stockle, U.1    Konig, B.2    Schaser, K.3    Melcher, I.4    Haas, N.P.5
  • 12
    • 34247136630 scopus 로고    scopus 로고
    • Image guidance in pelvic and acetabular surgery-Expectations, success and limitations
    • DOI 10.1016/j.injury.2007.01.024, PII S0020138307000277, Pelvic and Acetabular Surgery
    • Stöckle U, Schaser K, König B (2007) Image guidance in pelvic and acetabular surgery - expectations, success and limitations. Injury 38:450-462 (Pubitemid 46584674)
    • (2007) Injury , vol.38 , Issue.4 , pp. 450-462
    • Stockle, U.1    Schaser, K.2    Konig, B.3
  • 15
    • 1542299012 scopus 로고    scopus 로고
    • Fluoroscopy-Based Surgical Navigation versus Fluoroscopic Guidance to Control Guide Wire Insertion for Osteosynthesis of Femoral Neck Fractures: An Experimental Study
    • DOI 10.1007/s00068-004-1267-2
    • Suhm N, Beck T, Zuna I, Marazzi C, Staedele H, Jacob AL, Messmer P, Regazzoni P (2004) Fluoroscopy-based surgical navigation versus fluoroscopic guidance to control guide wire insertion for osteosynthesis of femoral neck fractures. Eur J Trauma 1:23-28 (Pubitemid 38313495)
    • (2004) European Journal of Trauma , vol.30 , Issue.1 , pp. 23-28
    • Suhm, N.1    Beck, T.2    Zuna, I.3    Marazzi, C.4    Staedele, H.5    Jacob, A.L.6    Messmer, P.7    Regazzoni, P.8
  • 16
    • 78650957374 scopus 로고    scopus 로고
    • Evaluation of a fluoroscopy-based navigation system enabling a virtual radiation-free preview of X-ray images for placement of cannulated hip screws. A cadaver study
    • Mueller MC, Belei P, de la Fuente M, Strake M, Weber O, Burger C, Radermacher K, Wirtz DC (2011) Evaluation of a fluoroscopy-based navigation system enabling a virtual radiation-free preview of X-ray images for placement of cannulated hip screws. A cadaver study. Comp Aided Surg 16:22-31
    • (2011) Comp Aided Surg , vol.16 , pp. 22-31
    • Mueller, M.C.1    Belei, P.2    De La Fuente, M.3    Strake, M.4    Weber, O.5    Burger, C.6    Radermacher, K.7    Wirtz, D.C.8
  • 17
    • 18944374772 scopus 로고    scopus 로고
    • The complications of displaced intracapsular fractures of the hip. The effect of screw positioning and angulation on fracture healing
    • DOI 10.1302/0301-620X.87B5.15237
    • Gurusamy K, Parker MJ, Rowlands TK (2005) The complications of displaced intracapsular fractures of the hip: the effect of screw positioning and angulation on fracture healing. J Bone Joint Surg Br 87:632-634 (Pubitemid 40711634)
    • (2005) Journal of Bone and Joint Surgery - Series B , vol.87 , Issue.5 , pp. 632-634
    • Gurusamy, K.1    Parker, M.J.2    Rowlands, T.K.3
  • 19
    • 33750300647 scopus 로고    scopus 로고
    • Eine neue doppelbohrbüchse zur navigierten schenkelhalsverschraubung: Entwicklung und evaluation
    • DOI 10.1007/s00113-006-1142-1
    • Kendoff D, Hüfner T, Citak M, Maier C, Wesemeier F, Pearle A, Krettek C (2006) A new parallel drill guide for navigating femoral neck screw placement. Development and evaluation. Unfallchirurg 109:875-880 (Pubitemid 44624512)
    • (2006) Unfallchirurg , vol.109 , Issue.10 , pp. 875-880
    • Kendoff, D.1    Hufner, T.2    Citak, M.3    Maier, C.4    Wesemeier, F.5    Pearle, A.6    Krettek, C.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.