메뉴 건너뛰기




Volumn 57, Issue 7, 2012, Pages 1786-1791

Quality of polyp resection during colonoscopy: Are we achieving polyp clearance?

Author keywords

Biopsy forcep; Colon cancer screening; Colonoscopy; Colorectal neoplasia; Polypectomy; Snare

Indexed keywords

ADULT; AGED; ARTICLE; BIOPSY DEVICE; CANCER SCREENING; CLINICAL ARTICLE; COLD SNARE; COLON BIOPSY; COLON MUCOSA; COLON POLYP; CONTROLLED STUDY; ENDOSCOPIC POLYPECTOMY; FEMALE; FORCEPS; HEALTH CARE QUALITY; HISTOLOGY; HOT SNARE; HUMAN; HUMAN TISSUE; JUMBO BIOPSY FORCEPS; MALE; MINIMAL RESIDUAL DISEASE; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; RETROSPECTIVE STUDY; STANDARD BIOPSY FORCEPS; SURGICAL EQUIPMENT; UNITED STATES;

EID: 84864278748     PISSN: 01632116     EISSN: 15732568     Source Type: Journal    
DOI: 10.1007/s10620-012-2115-6     Document Type: Article
Times cited : (36)

References (24)
  • 3
    • 0033978198 scopus 로고    scopus 로고
    • Colonoscopic withdrawal technique is associated with adenoma miss rates
    • Rex DK. Colonoscopic withdrawal technique is associated with adenoma miss rates. Gastrointest Endosc. 2000;51:33-36. (Pubitemid 30051607)
    • (2000) Gastrointestinal Endoscopy , vol.51 , Issue.1 , pp. 33-36
    • Rex, D.K.1
  • 4
    • 0346811295 scopus 로고    scopus 로고
    • Impact of colonoscopy preparation quality on detection of suspected colonic neoplasia
    • DOI 10.1067/mge.2003.294
    • Harewood GC, Sharma VK, de Garmo P. Impact of colonoscopy preparation quality on detection of suspected colonic neoplasia. Gastrointest Endosc. 2003;58:76-79. (Pubitemid 38208751)
    • (2003) Gastrointestinal Endoscopy , vol.58 , Issue.1 , pp. 76-79
    • Harewood, G.C.1    Sharma, V.K.2    De Garmo, P.3
  • 7
    • 61549094968 scopus 로고    scopus 로고
    • The Boston bowel preparation scale: A valid and reliable instrument for colonoscopy-oriented research
    • Lai EJ, Calderwood AH, Doros G, et al. The Boston bowel preparation scale: a valid and reliable instrument for colonoscopy-oriented research. Gastrointest Endosc. 2009;69:620-625.
    • (2009) Gastrointest Endosc. , vol.69 , pp. 620-625
    • Lai, E.J.1    Calderwood, A.H.2    Doros, G.3    Et Al.4
  • 8
    • 59149106469 scopus 로고    scopus 로고
    • Polyps in the gastrointestinal tract: Discrepancy between endoscopic forceps and resected specimens
    • Sung HY, Cheung DY, Cho SH, et al. Polyps in the gastrointestinal tract: discrepancy between endoscopic forceps and resected specimens. Eur J Gastroenterol Hepatol. 2009;21:190-195.
    • (2009) Eur J Gastroenterol Hepatol. , vol.21 , pp. 190-195
    • Sung, H.Y.1    Cheung, D.Y.2    Cho, S.H.3    Et Al.4
  • 9
    • 4444370300 scopus 로고    scopus 로고
    • A survey of colonoscopic polypectomy practices among clinical gastroenterologists
    • DOI 10.1016/S0016-5107(04)01808-5, PII S0016510704018085
    • Singh N, Harrison M, Rex DK. A survey of colonoscopic polypectomy practices among clinical gastroenterologists. Gastrointest Endosc. 2004;60:414-418. (Pubitemid 39164252)
    • (2004) Gastrointestinal Endoscopy , vol.60 , Issue.3 , pp. 414-418
    • Singh, N.1    Harrison, M.2    Rex, D.K.3
  • 11
    • 0024580548 scopus 로고
    • Adequacy of 'hot biopsy' for the treatment of diminutive polyps: A prospective randomized trial
    • Vanagunas A, Jacob P, Vakil N. Adequacy of "hot biopsy" for the treatment of diminutive polyps: a prospective randomized trial. Am J Gastroenterol. 1989;84:383-385. (Pubitemid 19106400)
    • (1989) American Journal of Gastroenterology , vol.84 , Issue.4 , pp. 383-385
    • Vanagunas, A.1    Jacob, P.2    Vakil, N.3
  • 12
    • 79953646634 scopus 로고    scopus 로고
    • Biopsy forceps is inadequate for the resection of diminutive polyps
    • Efthymiou M, Taylor ACF, Desmond PV, et al. Biopsy forceps is inadequate for the resection of diminutive polyps. Endoscopy. 2011;43:312-316.
    • (2011) Endoscopy , vol.43 , pp. 312-316
    • Efthymiou, M.1    Taylor, A.C.F.2    Desmond, P.V.3    Et Al.4
  • 13
    • 0024829296 scopus 로고
    • Eradication of diminutive polyps: A prospective evaluation of bipolar coagulation versus conventional biopsy removal
    • Woods A, Sanowski RA, Wadas DD, et al. Eradication of diminutive polyps:a prospective evaluation of bipolar coagulation versus conventional biopsy removal. Gastrointest Endosc. 1989;35:536-540. (Pubitemid 20072410)
    • (1989) Gastrointestinal Endoscopy , vol.35 , Issue.6 , pp. 536-540
    • Woods, A.1    Sanowski, R.A.2    Wadas, D.D.3    Manne, R.K.4    Friess, S.W.5
  • 18
    • 0028298703 scopus 로고
    • Tiny snares prove safe and effective for removal of diminutive colorectal polyps
    • McAfee JH, Katon RM. Tiny snares prove safe and effective for removal of diminutive colorectal polyps. Gastrointest Endosc. 1994;40:301-303. (Pubitemid 24163066)
    • (1994) Gastrointestinal Endoscopy , vol.40 , Issue.3 , pp. 301-303
    • McAfee, J.H.1    Katon, R.M.2
  • 24
    • 22544487556 scopus 로고    scopus 로고
    • Colon polyp retrieval after cold snaring
    • DOI 10.1016/S0016-5107(05)00376-7, PII S0016510705003767
    • Deenadayalu VP, Rex DK. Colon polyp retrieval after cold snaring. Gastrointest Endosc. 2005;62:253-256. (Pubitemid 41021553)
    • (2005) Gastrointestinal Endoscopy , vol.62 , Issue.2 , pp. 253-256
    • Deenadayalu, V.P.1    Rex, D.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.