메뉴 건너뛰기




Volumn 171-172, Issue , 2012, Pages 795-802

Flow injection amperometric determination of isoniazid using a screen-printed carbon electrode modified with silver hexacyanoferrates nanoparticles

Author keywords

Amperometric detector; Isoniazid determination; Screen printed modified electrode; Silver hexacyanoferates nanoparticles

Indexed keywords

AMPEROMETRIC DETECTOR; AMPEROMETRIC DETERMINATION; ANALYTICAL FREQUENCIES; CATALYTIC RESPONSE; ELECTROCHEMICAL BEHAVIORS; ELECTRODE SURFACES; FLOW INJECTION; FLOW-INJECTION ANALYSIS; HEXACYANOFERRATES; HEXACYANOFERRATES NANOPARTICLES; HUMAN URINE; ISONIAZID DETERMINATION; LIMIT OF DETECTION; LINEAR CALIBRATION CURVE; MEAN VALUES; MODIFIED ELECTRODES; OPERATION CONDITIONS; REDOX COUPLE; SAMPLE VOLUME; SCREEN PRINTED ELECTRODES; SCREEN-PRINTED CARBON ELECTRODES; SILVER IONS; SILVER NANOPARTICLES; SIMPLE METHOD; VOLTAMMETRIC PROFILES;

EID: 84864278642     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2012.05.073     Document Type: Article
Times cited : (69)

References (53)
  • 1
    • 0142165715 scopus 로고    scopus 로고
    • Screen-printed electrochemical sensors for monitoring metal pollutants
    • K.C. Honeychurch, and J.P. Hart Screen-printed electrochemical sensors for monitoring metal pollutants Trends in Analytical Chemistry 22 2003 456 469
    • (2003) Trends in Analytical Chemistry , vol.22 , pp. 456-469
    • Honeychurch, K.C.1    Hart, J.P.2
  • 2
    • 0031080914 scopus 로고    scopus 로고
    • Recent developments in the design and application of screen-printed electrochemical sensors for biomedical, environmental and industrial analyses
    • J.P. Hart, and S.A. Wring Recent developments in the design and application of screen-printed electrochemical sensors for biomedical, environmental and industrial analyses Trends in Analytical Chemistry 16 1997 89 103
    • (1997) Trends in Analytical Chemistry , vol.16 , pp. 89-103
    • Hart, J.P.1    Wring, S.A.2
  • 3
    • 0041694399 scopus 로고    scopus 로고
    • Developments in electrochemical sensors for occupational and environmental health applications
    • K. Ashley Developments in electrochemical sensors for occupational and environmental health applications Journal of Hazardous Materials 102 2003 1 12
    • (2003) Journal of Hazardous Materials , vol.102 , pp. 1-12
    • Ashley, K.1
  • 5
    • 33747305863 scopus 로고    scopus 로고
    • Anodic stripping voltammetric determination of aurothiomalate in urine using a screen-printed carbon electrode
    • M.F. Bergamini, and M.V.B. Zanoni Anodic stripping voltammetric determination of aurothiomalate in urine using a screen-printed carbon electrode Electroanalysis 18 2006 1457 1462
    • (2006) Electroanalysis , vol.18 , pp. 1457-1462
    • Bergamini, M.F.1    Zanoni, M.V.B.2
  • 6
    • 59149099614 scopus 로고    scopus 로고
    • Screen-printed carbon electrode modified with poly-l-histidine applied to gold (III) determination
    • M.F. Bergamini, D.P. Santos, and M.V.B. Zanoni Screen-printed carbon electrode modified with poly-l-histidine applied to gold (III) determination Journal of the Brazilian Chemical Society 20 2009 100 106
    • (2009) Journal of the Brazilian Chemical Society , vol.20 , pp. 100-106
    • Bergamini, M.F.1    Santos, D.P.2    Zanoni, M.V.B.3
  • 7
    • 34247634012 scopus 로고    scopus 로고
    • Development of a voltammetric sensor for chromium(VI) determination in wastewater sample
    • M.F. Bergamini, D.P. Santos, and M.V.B. Zanoni Development of a voltammetric sensor for chromium(VI) determination in wastewater sample Sensors and Actuators B 123 2007 902 908
    • (2007) Sensors and Actuators B , vol.123 , pp. 902-908
    • Bergamini, M.F.1    Santos, D.P.2    Zanoni, M.V.B.3
  • 8
    • 33846796296 scopus 로고    scopus 로고
    • Detection of cadmium sulphide nanoparticles by using screen-printed electrodes and a handheld device
    • Article Number: 035502
    • A. Merkoçi, L.H. Marcolino-Junior, S. Marín, O. Fatibello-Filho, and S. Alegret Detection of cadmium sulphide nanoparticles by using screen-printed electrodes and a handheld device Nanotechnology 18 2007 Article Number: 035502
    • (2007) Nanotechnology , vol.18
    • Merkoçi, A.1    Marcolino-Junior, L.H.2    Marín, S.3    Fatibello-Filho, O.4    Alegret, S.5
  • 9
    • 77956580009 scopus 로고    scopus 로고
    • Metal nanoparticle modified boron doped diamond electrodes for use in electroanalysis
    • K.E. Toghill, and R.G. Compton Metal nanoparticle modified boron doped diamond electrodes for use in electroanalysis Electroanalysis 22 2010 1947 1956
    • (2010) Electroanalysis , vol.22 , pp. 1947-1956
    • Toghill, K.E.1    Compton, R.G.2
  • 11
    • 77949911842 scopus 로고    scopus 로고
    • Recent nanoarchitectures in metal nanoparticle-modified electrode for electroanalysis
    • M. Oyama Recent nanoarchitectures in metal nanoparticle-modified electrode for electroanalysis Analytical Sciences 26 2010 1 12
    • (2010) Analytical Sciences , vol.26 , pp. 1-12
    • Oyama, M.1
  • 13
    • 84857993347 scopus 로고    scopus 로고
    • Electroanalytical application of a screen-printed electrode modified by dodecanethiol-stabilized platinum nanoparticles for dapsone determination
    • F.R. Caetano, A. Gevaerd, E.G. Castro, M.F. Bergamini, A.J.G. Zarbin, and L.H. Marcolino-Junior. Electroanalytical application of a screen-printed electrode modified by dodecanethiol-stabilized platinum nanoparticles for dapsone determination Electrochimica Acta 66 2012 265 270
    • (2012) Electrochimica Acta , vol.66 , pp. 265-270
    • Caetano, F.R.1    Gevaerd, A.2    Castro, E.G.3    Bergamini, M.F.4    Zarbin, A.J.G.5    Marcolino-Junior, L.H.6
  • 14
    • 75249104214 scopus 로고    scopus 로고
    • Dodecanethiol-stabilized platinum nanoparticles obtained by a two-phase method: Synthesis, characterization, mechanism of formation, and electrocatalytic properties
    • E.G. Castro, R.V. Salvatierra, W.H. Schreiner, M.M. Oliveira, and A.J.G. Zarbin Dodecanethiol-stabilized platinum nanoparticles obtained by a two-phase method: synthesis, characterization, mechanism of formation, and electrocatalytic properties Chemistry of Materials 22 2010 360
    • (2010) Chemistry of Materials , vol.22 , pp. 360
    • Castro, E.G.1    Salvatierra, R.V.2    Schreiner, W.H.3    Oliveira, M.M.4    Zarbin, A.J.G.5
  • 16
    • 79955875986 scopus 로고    scopus 로고
    • Electrocatalytic oxidation and detection of hydrazine at carbon nanotube-supported palladium nanoparticles in strong acidic solution conditions
    • J. Zhao, M. Zhu, M. Zheng, Y. Tang, Y. Chen, and T. Lu Electrocatalytic oxidation and detection of hydrazine at carbon nanotube-supported palladium nanoparticles in strong acidic solution conditions Electrochimica Acta 56 2011 4930
    • (2011) Electrochimica Acta , vol.56 , pp. 4930
    • Zhao, J.1    Zhu, M.2    Zheng, M.3    Tang, Y.4    Chen, Y.5    Lu, T.6
  • 17
    • 0042526132 scopus 로고    scopus 로고
    • Metal hexacyanoferrates: Electrosynthesis, in situ characterization, and applications
    • N.R. Tacconi, and K. Rajeshwar Metal hexacyanoferrates: electrosynthesis, in situ characterization, and applications Chemistry of Materials 15 2003 3046 3062
    • (2003) Chemistry of Materials , vol.15 , pp. 3046-3062
    • Tacconi, N.R.1    Rajeshwar, K.2
  • 18
    • 0034922653 scopus 로고    scopus 로고
    • Prussian blue and its analogues: Electrochemistry and analytical applications
    • A.A. Karyakin Prussian blue and its analogues: electrochemistry and analytical applications Electroanalysis 13 2001 813 819
    • (2001) Electroanalysis , vol.13 , pp. 813-819
    • Karyakin, A.A.1
  • 19
    • 75749117469 scopus 로고    scopus 로고
    • Preparation of silver hexacyanoferrate nanoparticles and its application for the simultaneous determination of ascorbic acid, dopamine and uric acid
    • M. Noroozifar, M. Khorasani-Motlagh, and A. Taheri Preparation of silver hexacyanoferrate nanoparticles and its application for the simultaneous determination of ascorbic acid, dopamine and uric acid Talanta 80 2010 1657 1664
    • (2010) Talanta , vol.80 , pp. 1657-1664
    • Noroozifar, M.1    Khorasani-Motlagh, M.2    Taheri, A.3
  • 20
    • 33748289505 scopus 로고    scopus 로고
    • Electrocatalytic oxidation and amperometric determination of BHA at graphite-wax composite electrode with silver hexacyanoferrate as electrocatalyst
    • D. Jayasri, and S.S. Narayanan Electrocatalytic oxidation and amperometric determination of BHA at graphite-wax composite electrode with silver hexacyanoferrate as electrocatalyst Sensors and Actuators B 119 2006 135 142
    • (2006) Sensors and Actuators B , vol.119 , pp. 135-142
    • Jayasri, D.1    Narayanan, S.S.2
  • 21
    • 79955579644 scopus 로고    scopus 로고
    • Silver nanocomposite electrode modified with hexacyanoferrate. Preparation, characterization and electrochemical behaviour towards substituted anilines
    • P.G. Fenga, N.R. Stradiotto, and M.I. Pividori Silver nanocomposite electrode modified with hexacyanoferrate. Preparation, characterization and electrochemical behaviour towards substituted anilines Electroanalysis 23 2011 1100 1106
    • (2011) Electroanalysis , vol.23 , pp. 1100-1106
    • Fenga, P.G.1    Stradiotto, N.R.2    Pividori, M.I.3
  • 22
    • 78549295840 scopus 로고    scopus 로고
    • Determination of cyanide in wastewaters using modified glassy carbon electrode with immobilized silver hexacyanoferrate nanoparticles on multiwall carbon nanotube
    • M. Noroozifar, M. Khorasani-Motlagh, and A. Taheri Determination of cyanide in wastewaters using modified glassy carbon electrode with immobilized silver hexacyanoferrate nanoparticles on multiwall carbon nanotube Journal of Hazardous Materials 185 2011 255 261
    • (2011) Journal of Hazardous Materials , vol.185 , pp. 255-261
    • Noroozifar, M.1    Khorasani-Motlagh, M.2    Taheri, A.3
  • 23
    • 33644977519 scopus 로고    scopus 로고
    • Voltammetric determination of N-acetylcysteine using a carbon paste electrode modified with copper(II) hexacyanoferrate(III)
    • W.T. Suarez, L.H. Marcolino Jr., and O. Fatibello-Filho Voltammetric determination of N-acetylcysteine using a carbon paste electrode modified with copper(II) hexacyanoferrate(III) Microchemical Journal 82 2006 163 167
    • (2006) Microchemical Journal , vol.82 , pp. 163-167
    • Suarez, W.T.1    Marcolino Jr., L.H.2    Fatibello-Filho, O.3
  • 24
    • 3042587220 scopus 로고    scopus 로고
    • Voltammetric determination of isoprenaline in pharmaceutical preparations using a copper (II) hexacyanoferrate (III) modified carbon paste electrode
    • V.G. Bonifácio, L.H. Marcolino Jr., M.F.S. Teixeira, and O. Fatibello-Filho Voltammetric determination of isoprenaline in pharmaceutical preparations using a copper (II) hexacyanoferrate (III) modified carbon paste electrode Microchemical Journal 78 2004 55 59
    • (2004) Microchemical Journal , vol.78 , pp. 55-59
    • Bonifácio, V.G.1    Marcolino Jr., L.H.2    Teixeira, M.F.S.3    Fatibello-Filho, O.4
  • 26
    • 0003700389 scopus 로고
    • American Society of Hospital Pharmacists Bethesda, MD pp. 344-348
    • G.K. Mcevory AHFS Drug Information 1990 American Society of Hospital Pharmacists Bethesda, MD pp. 344-348
    • (1990) AHFS Drug Information
    • McEvory, G.K.1
  • 27
    • 0032855464 scopus 로고    scopus 로고
    • A sensitive and specific method for isoniazid determination based on selective adsorption using an isoniazid ion-selective piezoelectric sensor
    • S. Yao, W. Li, X. Su, X. Zuo, and W. Wei A sensitive and specific method for isoniazid determination based on selective adsorption using an isoniazid ion-selective piezoelectric sensor Talanta 50 1999 469 480
    • (1999) Talanta , vol.50 , pp. 469-480
    • Yao, S.1    Li, W.2    Su, X.3    Zuo, X.4    Wei, W.5
  • 28
    • 0035909446 scopus 로고    scopus 로고
    • Flow-injection chemiluminescence sensor for the determination of isoniazid
    • S. Zhang, and H. Li Flow-injection chemiluminescence sensor for the determination of isoniazid Analytica Chimica Acta 444 2001 287 294
    • (2001) Analytica Chimica Acta , vol.444 , pp. 287-294
    • Zhang, S.1    Li, H.2
  • 29
    • 0034663881 scopus 로고    scopus 로고
    • Fluorimetric determination of isoniazid by oxidation with cerium (IV) in a multicommutated flow system
    • R.A.S. Lapa, J.L.F.C. Lima, and J.L.M. Santos Fluorimetric determination of isoniazid by oxidation with cerium (IV) in a multicommutated flow system Analytica Chimica Acta 419 2000 17 23
    • (2000) Analytica Chimica Acta , vol.419 , pp. 17-23
    • Lapa, R.A.S.1    Lima, J.L.F.C.2    Santos, J.L.M.3
  • 30
    • 0032988730 scopus 로고    scopus 로고
    • Simultaneous determination of rifampicin, isoniazid and pyrazinamide in tablet preparations by multivariate spectrophotometric calibration
    • H.C. Goicoechea, and A.C. Olivieri Simultaneous determination of rifampicin, isoniazid and pyrazinamide in tablet preparations by multivariate spectrophotometric calibration Journal of Pharmaceutical and Biomedical Analysis 20 1999 681 686
    • (1999) Journal of Pharmaceutical and Biomedical Analysis , vol.20 , pp. 681-686
    • Goicoechea, H.C.1    Olivieri, A.C.2
  • 31
    • 0032898729 scopus 로고    scopus 로고
    • Detection of hydrazine, methylhydrazine and isoniazid by capillary electrophoresis with a 4-pyridyl hydroquinone self-assembled microdisk platinum electrode
    • T. You, L. Niu, J.Y. Gui, S. Dong, and E. Wang Detection of hydrazine, methylhydrazine and isoniazid by capillary electrophoresis with a 4-pyridyl hydroquinone self-assembled microdisk platinum electrode Journal of Pharmaceutical and Biomedical Analysis 19 1999 231 237
    • (1999) Journal of Pharmaceutical and Biomedical Analysis , vol.19 , pp. 231-237
    • You, T.1    Niu, L.2    Gui, J.Y.3    Dong, S.4    Wang, E.5
  • 32
    • 0036681479 scopus 로고    scopus 로고
    • Validation of a RP-LC method for the simultaneous determination of isoniazid, pyrazinamide and rifampicin in a pharmaceutical formulation
    • E. Calleri, E. De Lorenzi, S. Furlanetto, G. Massolini, and G. Caccialanza Validation of a RP-LC method for the simultaneous determination of isoniazid, pyrazinamide and rifampicin in a pharmaceutical formulation Journal of Pharmaceutical and Biomedical Analysis 29 2002 1089 1096
    • (2002) Journal of Pharmaceutical and Biomedical Analysis , vol.29 , pp. 1089-1096
    • Calleri, E.1    De Lorenzi, E.2    Furlanetto, S.3    Massolini, G.4    Caccialanza, G.5
  • 33
    • 0036162228 scopus 로고    scopus 로고
    • Liquid chromatographic determination of isoniazid, pyrazinamide and rifampicin from pharmaceutical preparations and blood
    • M.Y. Khuhawar, and F.M.A. Rind Liquid chromatographic determination of isoniazid, pyrazinamide and rifampicin from pharmaceutical preparations and blood Journal of Chromatography B 766 2002 357 363
    • (2002) Journal of Chromatography B , vol.766 , pp. 357-363
    • Khuhawar, M.Y.1    Rind, F.M.A.2
  • 34
    • 0242541151 scopus 로고    scopus 로고
    • Electrochemical behavior of the antituberculosis drug isoniazid and its square-wave adsorptive stripping voltammetric estimation in bulk form, tablets and biological fluids at a mercury electrode
    • M.M. Ghoneim, K.Y. El-Baradie, and A. Tawfik Electrochemical behavior of the antituberculosis drug isoniazid and its square-wave adsorptive stripping voltammetric estimation in bulk form, tablets and biological fluids at a mercury electrode Journal of Pharmaceutical and Biomedical Analysis 33 2003 673 685
    • (2003) Journal of Pharmaceutical and Biomedical Analysis , vol.33 , pp. 673-685
    • Ghoneim, M.M.1    El-Baradie, K.Y.2    Tawfik, A.3
  • 35
    • 1842472205 scopus 로고    scopus 로고
    • Voltammetric assay of rifampicin and isoniazid drugs, separately and combined in bulk, pharmaceutical formulations and human serum at a carbon paste electrode
    • E. Hammam, A.M. Beltagi, and M.M. Ghoneim Voltammetric assay of rifampicin and isoniazid drugs, separately and combined in bulk, pharmaceutical formulations and human serum at a carbon paste electrode Microchemical Journal 77 2004 53 62
    • (2004) Microchemical Journal , vol.77 , pp. 53-62
    • Hammam, E.1    Beltagi, A.M.2    Ghoneim, M.M.3
  • 36
    • 33645860494 scopus 로고    scopus 로고
    • Voltammetric behavior and determination of isoniazid in pharmaceuticals by using overoxidized polypyrrole glassy carbon modified electrode
    • M.R. Majidi, A. Jouyban, and K. Asadpour-Zeynali Voltammetric behavior and determination of isoniazid in pharmaceuticals by using overoxidized polypyrrole glassy carbon modified electrode Journal of Electroanalytical Chemistry 589 2006 32 37
    • (2006) Journal of Electroanalytical Chemistry , vol.589 , pp. 32-37
    • Majidi, M.R.1    Jouyban, A.2    Asadpour-Zeynali, K.3
  • 37
    • 33847669175 scopus 로고    scopus 로고
    • Multi-walled carbon nanotube paste electrode for selective voltammetric detection of isoniazid
    • S. Shahrokhian, and M. Amiri Multi-walled carbon nanotube paste electrode for selective voltammetric detection of isoniazid Microchimica Acta 157 2007 149 158
    • (2007) Microchimica Acta , vol.157 , pp. 149-158
    • Shahrokhian, S.1    Amiri, M.2
  • 38
    • 74449085563 scopus 로고    scopus 로고
    • Determination of isoniazid in human urine using screen-printed carbon electrode modified with poly-l-histidine
    • M.F. Bergamini, D.P. Santos, and M.V.B. Zanoni Determination of isoniazid in human urine using screen-printed carbon electrode modified with poly-l-histidine Bioelectrochemistry 77 2010 133 138
    • (2010) Bioelectrochemistry , vol.77 , pp. 133-138
    • Bergamini, M.F.1    Santos, D.P.2    Zanoni, M.V.B.3
  • 39
    • 84907768132 scopus 로고
    • Classification and definition of analytical methods based on flowing media
    • W.E. van der Linden Classification and definition of analytical methods based on flowing media Pure and Applied Chemistry 66 1994 2493 2500
    • (1994) Pure and Applied Chemistry , vol.66 , pp. 2493-2500
    • Van Der Linden, W.E.1
  • 41
    • 34047276255 scopus 로고    scopus 로고
    • An improved flow system for chloride determination in natural waters exploiting solid-phase reactor and long pathlength spectrophotometry
    • V.G. Bonifácio, L.C. Figueiredo-Filho, L.H. Marcolino Jr., and O. Fatibello-Filho An improved flow system for chloride determination in natural waters exploiting solid-phase reactor and long pathlength spectrophotometry Talanta 72 2007 663 667
    • (2007) Talanta , vol.72 , pp. 663-667
    • Bonifácio, V.G.1    Figueiredo-Filho, L.C.2    Marcolino Jr., L.H.3    Fatibello-Filho, O.4
  • 42
    • 17144442725 scopus 로고    scopus 로고
    • Flow injection amperometric determination of dipyrone in pharmaceutical formulations using a carbon paste electrode
    • L.H. Marcolino Jr., M.F. Bergamini, M.F.S. Teixeira, E.T.G. Cavalheiro, and O. Fatibello-Filho Flow injection amperometric determination of dipyrone in pharmaceutical formulations using a carbon paste electrode Il Farmaco 58 2003 999 1004
    • (2003) Il Farmaco , vol.58 , pp. 999-1004
    • Marcolino Jr., L.H.1    Bergamini, M.F.2    Teixeira, M.F.S.3    Cavalheiro, E.T.G.4    Fatibello-Filho, O.5
  • 43
    • 79551542365 scopus 로고    scopus 로고
    • Electrochemical evaluation of the a carbon-paste electrode modified with spinel manganese (IV) oxide under flow conditions for amperometric determination of lithium
    • P.A. Raymundo-Pereira, C.S. Martin, M.F. Bergamini, N. Bocchi, and M.F.S. Teixeira Electrochemical evaluation of the a carbon-paste electrode modified with spinel manganese (IV) oxide under flow conditions for amperometric determination of lithium Electrochimica Acta 56 2011 2552 2558
    • (2011) Electrochimica Acta , vol.56 , pp. 2552-2558
    • Raymundo-Pereira, P.A.1    Martin, C.S.2    Bergamini, M.F.3    Bocchi, N.4    Teixeira, M.F.S.5
  • 44
    • 27744585152 scopus 로고    scopus 로고
    • Influence of synthetic parameters on the size, structure, and stability of dodecanethiol-stabilized silver nanoparticles
    • M.M. Oliveira, D. Ugarte, D. Zanchet, and A.J.G. Zarbin Influence of synthetic parameters on the size, structure, and stability of dodecanethiol-stabilized silver nanoparticles Journal of Colloid and Interface Science 292 2005 429 435
    • (2005) Journal of Colloid and Interface Science , vol.292 , pp. 429-435
    • Oliveira, M.M.1    Ugarte, D.2    Zanchet, D.3    Zarbin, A.J.G.4
  • 45
    • 0030290971 scopus 로고    scopus 로고
    • Application of time-resolved EQCM to the study of the mechanism of silver (I) oxide formation on a polycrystalline silver electrode in alkaline solution
    • S. Chen, B. Wu, and C. Cha Application of time-resolved EQCM to the study of the mechanism of silver (I) oxide formation on a polycrystalline silver electrode in alkaline solution Journal of Electroanalytical Chemistry 416 1996 53 59
    • (1996) Journal of Electroanalytical Chemistry , vol.416 , pp. 53-59
    • Chen, S.1    Wu, B.2    Cha, C.3
  • 46
    • 0001129683 scopus 로고
    • Kinetics of electrolysis of transition-metal hexacyanide films and reduction of silver ferricyanide
    • S.B. Moon, A. Xidis, and V.D. Neff Kinetics of electrolysis of transition-metal hexacyanide films and reduction of silver ferricyanide Journal of Physical Chemistry 97 1993 1634 1638
    • (1993) Journal of Physical Chemistry , vol.97 , pp. 1634-1638
    • Moon, S.B.1    Xidis, A.2    Neff, V.D.3
  • 47
    • 0034610944 scopus 로고    scopus 로고
    • The solid-state electrochemistry of metal octacyanomolybdates, octacyanotungstates, and hexacyanoferrates explained on the basis of dissolution and reprecipitation reactions, lattice structures, and crystallinities
    • U. Schro1der, and F. Scholz The solid-state electrochemistry of metal octacyanomolybdates, octacyanotungstates, and hexacyanoferrates explained on the basis of dissolution and reprecipitation reactions, lattice structures, and crystallinities Inorganic Chemistry 39 2000 1006 1015
    • (2000) Inorganic Chemistry , vol.39 , pp. 1006-1015
    • Schroder, U.1    Scholz, F.2
  • 48
    • 3142671401 scopus 로고    scopus 로고
    • Countercation intercalation and kinetics of charge transport during redox reactions of nickel hexacyanoferrate
    • M.A. Malik, P.J. Kulesza, R. Marassi, F. Nobili, K. Miecznikowski, and S. Zamponi Countercation intercalation and kinetics of charge transport during redox reactions of nickel hexacyanoferrate Electrochimica Acta 49 2004 4253 4258
    • (2004) Electrochimica Acta , vol.49 , pp. 4253-4258
    • Malik, M.A.1    Kulesza, P.J.2    Marassi, R.3    Nobili, F.4    Miecznikowski, K.5    Zamponi, S.6
  • 49
    • 33645661504 scopus 로고    scopus 로고
    • Evaluation of different voltammetric techniques in the determination of amoxicillin using a carbon paste electrode modified with [N,N'- ethylenebis(salicylideneaminato)] oxovanadium (IV)
    • M.F. Bergamini, M.F.S. Teixeira, E.R. Dockal, N. Bocchi, and E.T.G. Cavalheiro Evaluation of different voltammetric techniques in the determination of amoxicillin using a carbon paste electrode modified with [N,N'- ethylenebis(salicylideneaminato)] oxovanadium (IV) Journal of the Electrochemical Society 153 2006 94 98
    • (2006) Journal of the Electrochemical Society , vol.153 , pp. 94-98
    • Bergamini, M.F.1    Teixeira, M.F.S.2    Dockal, E.R.3    Bocchi, N.4    Cavalheiro, E.T.G.5
  • 52
    • 79957830362 scopus 로고    scopus 로고
    • Electrochemical behaviors and determination of isoniazid at ordered mesoporous carbon modified electrode
    • L. Guo, X. Yan, and X. Bo Electrochemical behaviors and determination of isoniazid at ordered mesoporous carbon modified electrode Sensors and Actuators B 155 2011 837 842
    • (2011) Sensors and Actuators B , vol.155 , pp. 837-842
    • Guo, L.1    Yan, X.2    Bo, X.3
  • 53
    • 84155172008 scopus 로고    scopus 로고
    • Cobalt hexacyanoferrate modified multi-walled carbon nanotubes/graphite composite electrode as electrochemical sensor on microfluidic chip
    • Z. Chen, Y. Zhong, X. Li, F. Yang, J. Pan, and Y. Liang Cobalt hexacyanoferrate modified multi-walled carbon nanotubes/graphite composite electrode as electrochemical sensor on microfluidic chip Analytica Chimica Acta 710 2012 118 124
    • (2012) Analytica Chimica Acta , vol.710 , pp. 118-124
    • Chen, Z.1    Zhong, Y.2    Li, X.3    Yang, F.4    Pan, J.5    Liang, Y.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.