-
1
-
-
4143092288
-
-
Guanabara Koogan, Rio de Janeiro
-
A. Korolkovas, J.H. Burckhalter, Química Farmacêutica, Guanabara Koogan, Rio de Janeiro, 1988, pp. 193-195.
-
(1988)
Química Farmacêutica
, pp. 193-195
-
-
Korolkovas, A.1
Burckhalter, J.H.2
-
2
-
-
0030604235
-
Dipyrone into the nucleus raphe magnus inhibits the rat nociceptive tail-flick reflex
-
Jones S.L. Dipyrone into the nucleus raphe magnus inhibits the rat nociceptive tail-flick reflex. Eur. J. Pharmacol. 318:1996;37-40.
-
(1996)
Eur. J. Pharmacol.
, vol.318
, pp. 37-40
-
-
Jones, S.L.1
-
4
-
-
4344596321
-
-
Atheneu Editora, São Paulo
-
C.F. Bittencount, Farmacopéia Brasileira, 3rd ed., Atheneu Editora, São Paulo, 1977, pp. 406-408.
-
(1977)
Farmacopéia Brasileira, 3rd Ed.
, pp. 406-408
-
-
Bittencount, C.F.1
-
5
-
-
0033788479
-
Second derivative ultraviolet spectrophotometry and HPTLC for the simultaneous determination of vitamin C and dipyrone
-
Aburjai T., Amro B.I., Aiedeh K., Abuirjeie M., Al-Khalil S. Second derivative ultraviolet spectrophotometry and HPTLC for the simultaneous determination of vitamin C and dipyrone. Pharmazie. 55:2000;751-754.
-
(2000)
Pharmazie
, vol.55
, pp. 751-754
-
-
Aburjai, T.1
Amro, B.I.2
Aiedeh, K.3
Abuirjeie, M.4
Al-Khalil, S.5
-
6
-
-
0008916144
-
Flow-injection fluorometric-determination of novalgin in pharmaceutical preparations
-
Perez-Ruiz T., Martinez-Lozano C., Tomas V., Carpena J. Flow-injection fluorometric-determination of novalgin in pharmaceutical preparations. Microchem. J. 47:1993;296-301.
-
(1993)
Microchem. J.
, vol.47
, pp. 296-301
-
-
Perez-Ruiz, T.1
Martinez-Lozano, C.2
Tomas, V.3
Carpena, J.4
-
7
-
-
0032715482
-
Chemiluminescence analysis of menadione sodium bisulfite and analgin in pharmaceutical preparations and biological fluids
-
Huang Y.M., Zhang C., Zhang X.R., Zhang Z.J. Chemiluminescence analysis of menadione sodium bisulfite and analgin in pharmaceutical preparations and biological fluids. J. Pharm. Biomed. Anal. 21:1999;817-825.
-
(1999)
J. Pharm. Biomed. Anal.
, vol.21
, pp. 817-825
-
-
Huang, Y.M.1
Zhang, C.2
Zhang, X.R.3
Zhang, Z.J.4
-
8
-
-
4243506678
-
A novel chemiluminescence flow-through sensor for the determination of analgin
-
Huang Y.M., Zhang C., Zhang X.R., Zhang Z.J. A novel chemiluminescence flow-through sensor for the determination of analgin. Fresenius J. Anal. Chem. 365:1999;381-383.
-
(1999)
Fresenius J. Anal. Chem.
, vol.365
, pp. 381-383
-
-
Huang, Y.M.1
Zhang, C.2
Zhang, X.R.3
Zhang, Z.J.4
-
11
-
-
0027982224
-
Flow-injection determination of novalgin using amperometric detection at a glassy-carbon electrode
-
Perez-Ruiz T., Tomas V., Martinez-Lozano C. Flow-injection determination of novalgin using amperometric detection at a glassy-carbon electrode. J. Pharm. Biomed. Anal. 12:1994;1109-1113.
-
(1994)
J. Pharm. Biomed. Anal.
, vol.12
, pp. 1109-1113
-
-
Perez-Ruiz, T.1
Tomas, V.2
Martinez-Lozano, C.3
-
12
-
-
0033678168
-
Modified microelectrodes and multivariate calibration for flow injection amperometric simultaneous determination of ascorbic acid, dopamine, epinephrine and dypirone
-
Matos R.C., Angnes L., Araújo M.C.U., Saldanha T.C.B. Modified microelectrodes and multivariate calibration for flow injection amperometric simultaneous determination of ascorbic acid, dopamine, epinephrine and dypirone. Analyst. 125:2000;2011-2015.
-
(2000)
Analyst
, vol.125
, pp. 2011-2015
-
-
Matos, R.C.1
Angnes, L.2
Araújo, M.C.U.3
Saldanha, T.C.B.4
-
13
-
-
0035206069
-
Amperometric determination of dypirone in pharmaceutical formulations with a flow cell containing gold electrodes from recordable compact discs
-
Munoz R.A.A., Matos R.C., Angnes L. Amperometric determination of dypirone in pharmaceutical formulations with a flow cell containing gold electrodes from recordable compact discs. J. Pharm. Sci. 90:2000;1972-1977.
-
(2000)
J. Pharm. Sci.
, vol.90
, pp. 1972-1977
-
-
Munoz, R.A.A.1
Matos, R.C.2
Angnes, L.3
-
14
-
-
0037014633
-
Evaluation of a new rigid carbon-castor oil polyurethane composite as an electrode material
-
Mendes R.K., Claro-Neto S., Cavalheiro E.T.G. Evaluation of a new rigid carbon-castor oil polyurethane composite as an electrode material. Talanta. 57:2002;909-917.
-
(2002)
Talanta
, vol.57
, pp. 909-917
-
-
Mendes, R.K.1
Claro-Neto, S.2
Cavalheiro, E.T.G.3
-
15
-
-
0000474868
-
New device for improving sensitivity and stabilization in flow-injection analysis
-
Bergamin F.H., Reis B.F., Zagatto E.A.G. New device for improving sensitivity and stabilization in flow-injection analysis. Anal. Chim. Acta. 97:1978;427-431.
-
(1978)
Anal. Chim. Acta
, vol.97
, pp. 427-431
-
-
Bergamin, F.H.1
Reis, B.F.2
Zagatto, E.A.G.3
-
16
-
-
0035400564
-
Glassy carbon electrodes: I. Characterization and electrochemical activation
-
Dekanski A., Stevanovic J., Stevanovic R., Nikolic B.Z., Jovanovic V.M. Glassy carbon electrodes: I. Characterization and electrochemical activation. Carbon. 39:2001;1195-1205.
-
(2001)
Carbon
, vol.39
, pp. 1195-1205
-
-
Dekanski, A.1
Stevanovic, J.2
Stevanovic, R.3
Nikolic, B.Z.4
Jovanovic, V.M.5
-
17
-
-
0030814930
-
Determination of ornidazole in pharmaceutical dosage forms based on reduction at an activated glassy carbon electrode
-
Ozkan S.A., Senturk Z., Biryol I. Determination of ornidazole in pharmaceutical dosage forms based on reduction at an activated glassy carbon electrode. Int. J. Pharm. 157:1997;137-144.
-
(1997)
Int. J. Pharm.
, vol.157
, pp. 137-144
-
-
Ozkan, S.A.1
Senturk, Z.2
Biryol, I.3
|