메뉴 건너뛰기




Volumn 71, Issue 2, 2012, Pages

Evaluating the accuracy of robotic assistance in spine surgery

(2)  Cahill, K S a   Wang, M Y a  

a NONE

Author keywords

[No Author keywords available]

Indexed keywords

CANNULA; CANNULATION; CLINICAL EVALUATION; COMPUTER ASSISTED TOMOGRAPHY; EUROPE; HUMAN; HYPERTROPHY; INTRAOPERATIVE RADIOTHERAPY; PEDICLE SCREW; PRIORITY JOURNAL; RADIOLOGIST; RANDOMIZED CONTROLLED TRIAL (TOPIC); RETROSPECTIVE STUDY; ROBOTICS; SHORT SURVEY; SPINE SURGERY; THORACIC SPINE; TREATMENT OUTCOME; UNITED STATES;

EID: 84864239253     PISSN: 0148396X     EISSN: None     Source Type: Journal    
DOI: 10.1227/01.neu.0000417535.07871.36     Document Type: Short Survey
Times cited : (20)

References (3)
  • 1
    • 84859955993 scopus 로고    scopus 로고
    • Accuracy of robot-assisted placement of lumbar and sacral pedicle screws: A prospective randomized comparison to conventional freehand screw implantation
    • Phila Pa 1976
    • Ringel F, Stuer C, Reinke A, et al. Accuracy of robot-assisted placement of lumbar and sacral pedicle screws: a prospective randomized comparison to conventional freehand screw implantation. Spine (Phila Pa 1976). 2012;37(8):E496-E501.
    • (2012) Spine , vol.37 , Issue.8
    • Ringel, F.1    Stuer, C.2    Reinke, A.3
  • 2
    • 80052594088 scopus 로고    scopus 로고
    • Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placement
    • Kantelhardt SR, Martinez R, Baerwinkel S, Burger R, Giese A, Rohde V. Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placement. Eur Spine J. 2011;20(6):860-868.
    • (2011) Eur Spine J , vol.20 , Issue.6 , pp. 860-868
    • Kantelhardt, S.R.1    Martinez, R.2    Baerwinkel, S.3    Burger, R.4    Giese, A.5    Rohde, V.6
  • 3
    • 78649412164 scopus 로고    scopus 로고
    • Clinical acceptance and accuracy assessment of spinal implants guided with SpineAssist surgical robot: Retrospective study
    • Phila Pa 1976
    • Devito DP, Kaplan L, Dietl R, Pfeiffer M, Horne D, Silberstein B, et al. Clinical acceptance and accuracy assessment of spinal implants guided with SpineAssist surgical robot: retrospective study. Spine (Phila Pa 1976). 2010;35(24):2109-2115.
    • (2010) Spine , vol.35 , Issue.24 , pp. 2109-2115
    • Devito, D.P.1    Kaplan, L.2    Dietl, R.3    Pfeiffer, M.4    Horne, D.5    Silberstein, B.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.