Volumn 39, Issue 7, 2012, Pages 4073-4078

Technical note: Patient-specific quality assurance methods for TomoDirectTM whole breast treatment delivery

Author keywords

breast; diode arrays; DQA; TomoDirect; TomoTherapy

Indexed keywords

DAIRIES; DIODES; PHANTOMS; QUALITY ASSURANCE; RADIOTHERAPY;

EID: 84864219751     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4722967     Document Type: Article
Times cited : (15)

References (7)
  • 1
    • 33645007934 scopus 로고    scopus 로고
    • Patient specific treatment verifications for helical tomotherapy treatment plans
    • 10.1118/1.2134929
    • S. D. Thomas, M. Mackenzie, G. C. Field, A. M. Syme, and B. G. Fallone, " Patient specific treatment verifications for helical tomotherapy treatment plans.," Med. Phys. 32, 3793-3800 (2005). 10.1118/1.2134929
    • (2005) Med. Phys. , vol.32 , pp. 3793-3800
    • Thomas, S.D.1    MacKenzie, M.2    Field, G.C.3    Syme, A.M.4    Fallone, B.G.5
  • 2
    • 78650524738 scopus 로고    scopus 로고
    • 3D analysis of intensity-modulated radiation therapy quality assurance measurement using a 2D diode array
    • 10.1088/1742-6596/250/1/012052
    • M. Lawrence, T. Cullip, L. Potter, J. Lian, S. Wang, Z. Xu, K. Burkhardt, and S. Chang, " 3D analysis of intensity-modulated radiation therapy quality assurance measurement using a 2D diode array.," J. Phys.: Conf. Ser. 250, 012052 (2010). 10.1088/1742-6596/250/1/012052
    • (2010) J. Phys.: Conf. Ser. , vol.250 , pp. 012052
    • Lawrence, M.1    Cullip, T.2    Potter, L.3    Lian, J.4    Wang, S.5    Xu, Z.6    Burkhardt, K.7    Chang, S.8
  • 3
    • 79960552723 scopus 로고    scopus 로고
    • Evaluation of a new VMAT QA device, or the "x" and "o" array geometries
    • V. Feygelman, G. Zhang, C. Stevens, and B. E. Nelms, " Evaluation of a new VMAT QA device, or the "X" and "O" array geometries.," J. Appl. Clin. Med. Phys. 12 (2), 3346 (2011).
    • (2011) J. Appl. Clin. Med. Phys. , vol.12 , Issue.2 , pp. 3346
    • Feygelman, V.1    Zhang, G.2    Stevens, C.3    Nelms, B.E.4
  • 4
    • 84864225905 scopus 로고    scopus 로고
    • Investigation of tomotherapy patient specific delivery quality assurance (DQA) using a cylindrical diodes array detector system
    • University of Colorado School of Medicine
    • University of Colorado School of Medicine, " Investigation of tomotherapy patient specific delivery quality assurance (DQA) using a cylindrical diodes array detector system.," Med. Phys. 37, 3269 (2010).
    • (2010) Med. Phys. , vol.37 , pp. 3269
  • 5
    • 0031861573 scopus 로고    scopus 로고
    • A technique for the quantitative evaluation of dose distributions
    • 10.1118/1.598248
    • D. A. Low, W. B. Harms, S. Mutic, and J. A. Purdy, " A technique for the quantitative evaluation of dose distributions.," Med. Phys. 25, 656-661 (1998). 10.1118/1.598248
    • (1998) Med. Phys. , vol.25 , pp. 656-661
    • Low, D.A.1    Harms, W.B.2    Mutic, S.3    Purdy, J.A.4
  • 6
    • 84875367782 scopus 로고    scopus 로고
    • Sun Nuclear (http:www.sunnuclear.com/medPhys/patientqa).
  • 7
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • J. M. Bland and D. G. Altman, " Statistical methods for assessing agreement between two methods of clinical measurement.," Lancet i, 307-310 (1986).
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2