Patient specific treatment verifications for helical tomotherapy treatment plans

Author keywords

[No Author keywords available]

Indexed keywords

CRITICAL STRUCTURES; DOSE DISTRIBUTIONS; DOSE MEASUREMENT; FILM MEASUREMENT; HELICAL TOMOTHERAPY; PATIENT SPECIFIC; TREATMENT PLANS; TREATMENT VERIFICATION;

EID: 33645007934     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2134929     Document Type: Article
Times cited : (34)

References (14)
  • 1
    • 0027141318 scopus 로고
    • Tomotherapy: A new concept for the delivery of conformal radiotherapy using dynamic collimation
    • T. R. Mackie et al., " Tomotherapy: A new concept for the delivery of conformal radiotherapy using dynamic collimation, " Med. Phys. 20, 1709-1719 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 1709-1719
    • MacKie, T.R.1
  • 2
    • 0031861573 scopus 로고    scopus 로고
    • A technique for the quantitative evaluation of dose distributions
    • D. Low, W. Harms, S. Mutic, and J. Purdy, " A technique for the quantitative evaluation of dose distributions, " Med. Phys. 25, 656-661 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 656-661
    • Low, D.1
  • 4
    • 0027316070 scopus 로고
    • Commissioning and QA of treatment planning computers
    • J. Van Dyk et al., " Commissioning and QA of treatment planning computers, " Int. J. Radiat. Oncol., Biol., Phys. 26, 261-273 (1993).
    • (1993) Int. J. Radiat. Oncol., Biol., Phys. , vol.26 , pp. 261-273
    • Van Dyk, J.1
  • 5
    • 14644436391 scopus 로고    scopus 로고
    • Performance analysis of a film dosimetric quality assurance procedure for IMRT with regard to the employment of quantitative evaluation methods
    • P. Winkler et al., " Performance analysis of a film dosimetric quality assurance procedure for IMRT with regard to the employment of quantitative evaluation methods, " Phys. Med. Biol. 50, 643-654 (2005).
    • (2005) Phys. Med. Biol. , vol.50 , pp. 643-654
    • Winkler, P.1
  • 7
    • 18844437217 scopus 로고    scopus 로고
    • A Monte Carlo derived TG-51 equivalent calibration for helical tomotherapy
    • S. D. Thomas, M. Mackenzie, D. W. O. Rogers, and B. G. Fallone, " A Monte Carlo derived TG-51 equivalent calibration for helical tomotherapy, " Med. Phys. 32, 1346-1353 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 1346-1353
    • Thomas, S.D.1
  • 8
    • 4043165773 scopus 로고    scopus 로고
    • Effect of processing time delay of the dose response of Kodak EDR2 film
    • N. L. Childress and I. I. Rosen, " Effect of processing time delay of the dose response of Kodak EDR2 film, " Med. Phys. 31, 2284-2288 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 2284-2288
    • Childress, N.L.1
  • 9
    • 0038247951 scopus 로고    scopus 로고
    • Characteristics of sensitometric curves of radiographic films
    • X. R. Zhu, S. Yoo, P. A. Jursinic, D. F. Grimm, F. Lopez, J. J. Rownd, and M. T. Gillin, " Characteristics of sensitometric curves of radiographic films, " Med. Phys. 30, 912-919 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 912-919
    • Zhu, X.R.1
  • 10
    • 21144451652 scopus 로고    scopus 로고
    • Fast radiographic film calibration for helical tomotherapy intensity modulated radiation therapy dose verification
    • Y. Yan, N. Papanikolaou, X. Weng, J. Penagaricano, and V. Ratanatharathorn, " Fast radiographic film calibration for helical tomotherapy intensity modulated radiation therapy dose verification, " Med. Phys. 32, 1566-1570 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 1566-1570
    • Yan, Y.1
  • 11
    • 0036735811 scopus 로고    scopus 로고
    • Dosimetric performance of an enhanced dose range radiographic film for intensity-modulated radiation therapy quality assurance
    • J. Olch, " Dosimetric performance of an enhanced dose range radiographic film for intensity-modulated radiation therapy quality assurance, " Med. Phys. 32, 2159-2168 (2002).
    • (2002) Med. Phys. , vol.32 , pp. 2159-2168
    • Olch1
  • 12
    • 33645461034 scopus 로고    scopus 로고
    • Radiotherapy equipment-coordinates, movements, and scales
    • (IEC, Geneva, Switzerland).
    • IEC, " Radiotherapy equipment-coordinates, movements, and scales, " IEC 61217, Edition 1.1 (IEC, Geneva, Switzerland, 2002 - 03).
    • (2002) IEC 61217, Edition 1.1
  • 13
    • 3442881436 scopus 로고    scopus 로고
    • Quality assurance of a helical tomotherapy machine
    • J. D. Fenwick et al., " Quality assurance of a helical tomotherapy machine, " Phys. Med. Biol. 49, 2933-2953 (2004).
    • (2004) Phys. Med. Biol. , vol.49 , pp. 2933-2953
    • Fenwick, J.D.1
  • 14
    • 17844367621 scopus 로고    scopus 로고
    • Retrospective analysis of 2D patient specific IMRT verifications
    • N. L Childress et al., " Retrospective analysis of 2D patient specific IMRT verifications, " Med. Phys. 32, 838-850 (2005).
    • (2005) Med. Phys. , vol.32 , pp. 838-850
    • Childress, N.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.