메뉴 건너뛰기




Volumn 70, Issue 9, 2012, Pages 2006-2011

Standardization of Ga-68 by coincidence measurements, liquid scintillation counting and 4πγ counting

Author keywords

Ga 68; Ge 68; Radionuclide standardization

Indexed keywords

ARGENTINA; COINCIDENCE MEASUREMENT; ELECTRON CAPTURE; GA-68; GAMMA-COUNTING; GE-68; LIQUID SCINTILLATION COUNTING; NAI DETECTOR; POSITRON EMISSION; POSITRON EMITTERS;

EID: 84864119924     PISSN: 09698043     EISSN: 18729800     Source Type: Journal    
DOI: 10.1016/j.apradiso.2012.02.066     Document Type: Article
Times cited : (7)

References (17)
  • 1
    • 33751087825 scopus 로고    scopus 로고
    • Implementation of the TDCR liquid scintillation method at CNEA-LMR, Argentina
    • Arenillas P., Cassette P. Implementation of the TDCR liquid scintillation method at CNEA-LMR, Argentina. Appl. Radiat. Isot. 2006, 64:1500-1504.
    • (2006) Appl. Radiat. Isot. , vol.64 , pp. 1500-1504
    • Arenillas, P.1    Cassette, P.2
  • 2
    • 84872500722 scopus 로고    scopus 로고
    • Table of Radionuclides. SÈVRES, Monographie BIPM-5.
    • Bé, M.M., et al., 2004. Table of Radionuclides. SÈVRES, Monographie BIPM-5.
    • (2004)
    • Bé, M.M.1
  • 3
    • 0034160026 scopus 로고    scopus 로고
    • MAC3: an electronic module for the processing of pulses delivered by a three photomultiplier liquid scintillation counting system
    • Bouchard J., Cassette P. MAC3: an electronic module for the processing of pulses delivered by a three photomultiplier liquid scintillation counting system. Appl. Radiat. Isot. 2000, 52:669-672.
    • (2000) Appl. Radiat. Isot. , vol.52 , pp. 669-672
    • Bouchard, J.1    Cassette, P.2
  • 4
    • 0023855292 scopus 로고
    • Calculation of liquid-scintillation detector efficiency
    • Broda R., Pochwalski K., Radoszewski T. Calculation of liquid-scintillation detector efficiency. Appl. Radiat. Isot. 1988, 39:159-164.
    • (1988) Appl. Radiat. Isot. , vol.39 , pp. 159-164
    • Broda, R.1    Pochwalski, K.2    Radoszewski, T.3
  • 5
    • 0034160025 scopus 로고    scopus 로고
    • Analysis of detection-efficiency variation techniques for the implementation of the TDCR method in liquid scintillation counting
    • Cassette P., Broda R., Hainos D., Terlikowska T. Analysis of detection-efficiency variation techniques for the implementation of the TDCR method in liquid scintillation counting. Appl. Radiat. Isot. 2000, 52:643-648.
    • (2000) Appl. Radiat. Isot. , vol.52 , pp. 643-648
    • Cassette, P.1    Broda, R.2    Hainos, D.3    Terlikowska, T.4
  • 7
    • 0007652519 scopus 로고
    • Mesure absolue de l'activité des radionuclides par la méthode des coincidences Β-γ.Etude d'une méthode de correction automatique des erreurs instrumentales
    • Gandy A. Mesure absolue de l'activité des radionuclides par la méthode des coincidences Β-γ.Etude d'une méthode de correction automatique des erreurs instrumentales. Int. J. Appl. Radiat. Isot. 1963, 14:385-396.
    • (1963) Int. J. Appl. Radiat. Isot. , vol.14 , pp. 385-396
    • Gandy, A.1
  • 8
    • 0020124141 scopus 로고
    • Evaluation of counting efficiency in liquid scintillation counting of Β-ray emitters
    • Grau A., García-Toraño E. Evaluation of counting efficiency in liquid scintillation counting of Β-ray emitters. Int. J. Appl. Radiat. Isot. 1981, 33:249-253.
    • (1981) Int. J. Appl. Radiat. Isot. , vol.33 , pp. 249-253
    • Grau, A.1    García-Toraño, E.2
  • 10
    • 79952992797 scopus 로고    scopus 로고
    • On the measurement of positron emitters with Ge detectors
    • Peyres V., García-Toraño E. On the measurement of positron emitters with Ge detectors. Nucl. Instrum. Methods 2011, A637:100-104.
    • (2011) Nucl. Instrum. Methods , vol.A637 , pp. 100-104
    • Peyres, V.1    García-Toraño, E.2
  • 11
    • 84872494264 scopus 로고    scopus 로고
    • Simplified model for efficiency calculation of high-energy beta emitters with post electron capture emissions by the TDCR method. Unpublished.
    • Rodrígues, D., 2011. Simplified model for efficiency calculation of high-energy beta emitters with post electron capture emissions by the TDCR method. Unpublished.
    • (2011)
    • Rodrígues, D.1
  • 15
    • 49349119805 scopus 로고
    • Improved correction formulae for coincidence counting
    • Smith D. Improved correction formulae for coincidence counting. Nucl. Instrum. Methods 1978, 152:505-516.
    • (1978) Nucl. Instrum. Methods , vol.152 , pp. 505-516
    • Smith, D.1
  • 16
    • 0020536212 scopus 로고
    • Some aspects of activity measurements with NaI(Tl) well-type detectors
    • Winkler G., Pavlik A. Some aspects of activity measurements with NaI(Tl) well-type detectors. Int. J. Appl. Radiat. Isot. 1983, 34:547-553.
    • (1983) Int. J. Appl. Radiat. Isot. , vol.34 , pp. 547-553
    • Winkler, G.1    Pavlik, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.