메뉴 건너뛰기




Volumn 113, Issue 5, 2008, Pages 265-280

Standardization of68Ge/68Ga using three liquid scintillation counting based methods

Author keywords

Anticoincidence counting; CIEMAT NIST method; Germanium 68; Liquid scintillation counting; Positron emitter; Standardization; TDCR method

Indexed keywords

CALIBRATION; DIAGNOSIS; LIQUIDS; MEDICAL IMAGING; NUCLEAR INSTRUMENTATION; SCINTILLATION; SCINTILLATION COUNTERS;

EID: 55349101663     PISSN: 1044677X     EISSN: None     Source Type: Journal    
DOI: 10.6028/jres.113.020     Document Type: Article
Times cited : (30)

References (27)
  • 1
    • 55349099359 scopus 로고    scopus 로고
    • G. Wiley, PET/CT: Market & Business Models for Ownership, Imaging Economics 6 (2006).
    • G. Wiley, PET/CT: Market & Business Models for Ownership, Imaging Economics 6 (2006).
  • 4
    • 55349141623 scopus 로고    scopus 로고
    • DDEP, Decay Data Evaluation Project Data
    • DDEP, Decay Data Evaluation Project Data, http://www. nucleide.org/DDEP_WG/DDEPdata.htm(2008).
    • (2008)
  • 9
    • 0002905521 scopus 로고
    • The enhanced triple to double coincidence ratio (ETDCR) method for standardization of radionuclides by liquid scintillation counting
    • R. Broda and K. Pochwalski, The enhanced triple to double coincidence ratio (ETDCR) method for standardization of radionuclides by liquid scintillation counting, Nucl. Inst. Meth. Phys. Res. A312, 85-89 (1992).
    • (1992) Nucl. Inst. Meth. Phys. Res , vol.A312 , pp. 85-89
    • Broda, R.1    Pochwalski, K.2
  • 10
    • 0023836315 scopus 로고
    • Standardization of pure beta emitters by liquid scintillation counting
    • K. Pochwalski, R. Broda, and T. Radoszewski, Standardization of pure beta emitters by liquid scintillation counting, Appl. Radiat. Isot. 39, 165-172 (1988).
    • (1988) Appl. Radiat. Isot , vol.39 , pp. 165-172
    • Pochwalski, K.1    Broda, R.2    Radoszewski, T.3
  • 14
    • 1342315913 scopus 로고    scopus 로고
    • National Institute of Standards and Technology, National Institute of Standards and Technology, Gaithersburg, MD
    • National Institute of Standards and Technology, Standard Reference Material 4927F, Radioactivity Standard, Hydrogen-3, (National Institute of Standards and Technology, Gaithersburg, MD, 2000).
    • (2000) Standard Reference Material 4927F, Radioactivity Standard, Hydrogen-3
  • 15
    • 43049120203 scopus 로고    scopus 로고
    • Liquid scintillation-based anticoincidence counting of Co-60 and Pb-210
    • R. Fitzgerald and M. K. Schultz, Liquid scintillation-based anticoincidence counting of Co-60 and Pb-210, Appl. Radiat. Isot. 66, 937-940 (2008).
    • (2008) Appl. Radiat. Isot , vol.66 , pp. 937-940
    • Fitzgerald, R.1    Schultz, M.K.2
  • 16
    • 0032146902 scopus 로고    scopus 로고
    • Calibration of the massic activity of a solution of Tc-99
    • L. L. Lucas, Calibration of the massic activity of a solution of Tc-99, Appl. Radit Isot. 49, 1061-1064 (1998).
    • (1998) Appl. Radit Isot , vol.49 , pp. 1061-1064
    • Lucas, L.L.1
  • 17
    • 1342329469 scopus 로고    scopus 로고
    • Construction and implementation of the NIST triple-to-double coincidence ratio (TDCR) spectrometer
    • B. E. Zimmerman, R. Collé, and J. T. Cessna, Construction and implementation of the NIST triple-to-double coincidence ratio (TDCR) spectrometer, Appl. Radiat. Isot. 60, 433-438 (2004).
    • (2004) Appl. Radiat. Isot , vol.60 , pp. 433-438
    • Zimmerman, B.E.1    Collé, R.2    Cessna, J.T.3
  • 18
    • 55349103984 scopus 로고    scopus 로고
    • Wolfram Research, Mathematica, v.4.0, (2001).
    • Wolfram Research, Mathematica, v.4.0, (2001).
  • 19
    • 1642326165 scopus 로고    scopus 로고
    • A review of the triple-to-double coincidence ratio (TDCR) method for standardizing radionuclides
    • R. Broda, A review of the triple-to-double coincidence ratio (TDCR) method for standardizing radionuclides, Appl. Radiat. Isot. 58, 585-594 (2003).
    • (2003) Appl. Radiat. Isot , vol.58 , pp. 585-594
    • Broda, R.1
  • 22
    • 0031274705 scopus 로고    scopus 로고
    • An algorithm for Monte Carlo simulation of the coupled electronphoton transport
    • J. Sempau, E. Acosta, J. M. Fernandez-Varea, and F. Salvat, An algorithm for Monte Carlo simulation of the coupled electronphoton transport., Nucl. Inst. Meth. B132, 377-390 (1997).
    • (1997) Nucl. Inst. Meth , vol.B132 , pp. 377-390
    • Sempau, J.1    Acosta, E.2    Fernandez-Varea, J.M.3    Salvat, F.4
  • 23
    • 33751102454 scopus 로고    scopus 로고
    • Monte Carlo calculations of spectra and interaction probabilities for photons in liquid scintillators for use in the standardization of radionuclides
    • B. E. Zimmerman, Monte Carlo calculations of spectra and interaction probabilities for photons in liquid scintillators for use in the standardization of radionuclides, Appl. Radiat. Isot. 64, 1492-1498 (2006).
    • (2006) Appl. Radiat. Isot , vol.64 , pp. 1492-1498
    • Zimmerman, B.E.1
  • 25
    • 55349100069 scopus 로고    scopus 로고
    • Labortoire National Henri Becquerel
    • Labortoire National Henri Becquerel, LS Sources Data, http://www.nucleide.org/ICRM_LSC_WG/icrmlsdata.htm (2008).
    • (2008) LS Sources Data
  • 27
    • 55349123846 scopus 로고    scopus 로고
    • E. Günther, CIENIST 2004, private communication (2004).
    • E. Günther, CIENIST 2004, private communication (2004).


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.