ARTICLE;
CHEMISTRY;
HUMAN;
ION EXCHANGE CHROMATOGRAPHY;
ISOLATION AND PURIFICATION;
ISOTOPE LABELING;
METHYLATION;
POLYACRYLAMIDE GEL ELECTROPHORESIS;
PROTEIN DEGRADATION;
TANDEM MASS SPECTROMETRY;
THROMBOCYTE;
BLOOD PLATELETS;
CELL EXTRACTS;
CHROMATOGRAPHY, ION EXCHANGE;
ELECTROPHORESIS, POLYACRYLAMIDE GEL;
HUMANS;
ISOTOPE LABELING;
METHYLATION;
PEPTIDE FRAGMENTS;
PROTEOLYSIS;
PROTEOME;
TANDEM MASS SPECTROMETRY;
TRYPSIN;
EID: 84864117133PISSN: 10643745EISSN: NoneSource Type: Book Series DOI: 10.1007/978-1-61779-885-6_8Document Type: Article
Stable isotope labeling by amino acids in cell culture SILAC as a simple and accurate approach to expression proteomics
Ong SE, Blagoev B, Kratchmarova I et al (2002) Stable isotope labeling by amino acids in cell culture, SILAC, as a simple and accurate approach to expression proteomics. Mol Cell Proteomics 1:376-386
Quantitative analysis of complex protein mixtures using isotope-coded af finity tags
Gygi SP, Rist B, Gerber SA et al (1999) Quantitative analysis of complex protein mixtures using isotope-coded af finity tags. Nat Biotechnol 17:994-999
Multiplexed protein quantitation in saccharomyces cerevisiae using amine-reactive isobaric tagging reagents
Ross PL, Huang YN, Marchese JN et al (2004) Multiplexed protein quantitation in Saccharomyces cerevisiae using amine-reactive isobaric tagging reagents. Mol Cell Proteomics 3:1154-1169
Relative quantification of proteins in human cerebrospinal fl uids by MS/MS using 6-plex isobaric tags
Dayon L, Hainard A, Licker V et al (2008) Relative quantification of proteins in human cerebrospinal fl uids by MS/MS using 6-plex isobaric tags. Anal Chem 80:2921-2931
Parts per million mass accuracy on an orbitrap mass spectrometer via lock mass injection into a C-trap
Olsen JV, De Godoy LM, Li G et al (2005) Parts per million mass accuracy on an Orbitrap mass spectrometer via lock mass injection into a C-trap. Mol Cell Proteomics 4:2010-2021
High-performance liquid chromatography-electrospray ionization mass spectrometry using monolithic capillary columns for proteomic studies
Premstaller A, Oberacher H, Walcher W et al (2001) High-performance liquid chromatography-electrospray ionization mass spectrometry using monolithic capillary columns for proteomic studies. Anal Chem 73:2390-2396
Organic solvent extraction of proteins and peptides from serum as an effective sample preparation for detection and identification of biomarkers by mass spectrometry
Chertov O, Biragyn A, Kwak LW et al (2004) Organic solvent extraction of proteins and peptides from serum as an effective sample preparation for detection and identification of biomarkers by mass spectrometry. Proteomics 4:1195-1203
Enrichment of low molecular weight serum proteins using acetonitrile precipitation for mass spectrometry based proteomic analysis
Kay R, Barton C, Ratcliffe L et al (2008) Enrichment of low molecular weight serum proteins using acetonitrile precipitation for mass spectrometry based proteomic analysis. Rapid Commun Mass Spectrom 22: 3255-3260