메뉴 건너뛰기




Volumn 67, Issue , 2012, Pages 225-230

A label-free immunosensor based on recordable compact disk chip for early diagnostic of the dengue virus infection

Author keywords

CD trode; Dengue; Electrochemical immunosensor; NS1

Indexed keywords

CD-TRODE; DENGUE; DENGUE HEMORRHAGIC FEVER; DENGUE VIRUS; DETECTION LIMITS; DIFFERENTIAL PULSE VOLTAMMETRY TECHNIQUES; ELECTROCHEMICAL IMMUNOSENSORS; GOLD FILM ELECTRODES; LABEL-FREE IMMUNOSENSOR; LINEAR RESPONSE; NS1; SERUM SAMPLES;

EID: 84864067286     PISSN: 1369703X     EISSN: 1873295X     Source Type: Journal    
DOI: 10.1016/j.bej.2012.06.016     Document Type: Article
Times cited : (44)

References (30)
  • 1
    • 35748929379 scopus 로고    scopus 로고
    • Dengue
    • Halstead S.B. Dengue. Lancet 2007, 370:1644-1652.
    • (2007) Lancet , vol.370 , pp. 1644-1652
    • Halstead, S.B.1
  • 4
    • 0036164518 scopus 로고    scopus 로고
    • Enzyme-linked immunosorbent assay specific to dengue virus type 1 nonstructural protein NS1 reveals circulation of the antigen in the blood during the acute phase of disease in patients experiencing primary or secondary infections
    • Alcon S., Talarmin A., Debruyne M., Falconar A., Deubel V., Flamand M. Enzyme-linked immunosorbent assay specific to dengue virus type 1 nonstructural protein NS1 reveals circulation of the antigen in the blood during the acute phase of disease in patients experiencing primary or secondary infections. J. Clin. Microbiol. 2002, 40:376-381.
    • (2002) J. Clin. Microbiol. , vol.40 , pp. 376-381
    • Alcon, S.1    Talarmin, A.2    Debruyne, M.3    Falconar, A.4    Deubel, V.5    Flamand, M.6
  • 7
    • 38949134184 scopus 로고    scopus 로고
    • An electrochemical biosensor of the ketone 3-[beta]-hydroxybutyrate for potential diabetic patient management
    • Fang L., Wang S-H., Liu C.C. An electrochemical biosensor of the ketone 3-[beta]-hydroxybutyrate for potential diabetic patient management. Sens. Actuators, B 2008, 129:818-825.
    • (2008) Sens. Actuators, B , vol.129 , pp. 818-825
    • Fang, L.1    Wang, S.-H.2    Liu, C.C.3
  • 8
    • 60349114715 scopus 로고    scopus 로고
    • Protein A-based antibody immobilization onto polymeric microdevices for enhanced sensitivity of enzyme-linked immunosorbent assay
    • Yuan Y., He H., Lee L.J. Protein A-based antibody immobilization onto polymeric microdevices for enhanced sensitivity of enzyme-linked immunosorbent assay. Biotechnol. Bioeng. 2009, 102:891-901.
    • (2009) Biotechnol. Bioeng. , vol.102 , pp. 891-901
    • Yuan, Y.1    He, H.2    Lee, L.J.3
  • 9
    • 39749124167 scopus 로고    scopus 로고
    • An overview of label-free electrochemical protein sensors
    • Vestergaard M., Kerman K., Tamiya E. An overview of label-free electrochemical protein sensors. Sensors 2007, 7:3442-3458.
    • (2007) Sensors , vol.7 , pp. 3442-3458
    • Vestergaard, M.1    Kerman, K.2    Tamiya, E.3
  • 10
    • 33244469462 scopus 로고    scopus 로고
    • Gold-based screen-printed sensor for detection of trace lead
    • Laschi S., Palchetti I., Mascini M. Gold-based screen-printed sensor for detection of trace lead. Sens. Actuators, B 2006, 114:460-465.
    • (2006) Sens. Actuators, B , vol.114 , pp. 460-465
    • Laschi, S.1    Palchetti, I.2    Mascini, M.3
  • 11
    • 30944465240 scopus 로고    scopus 로고
    • Disposable gold electrodes with reproducible area using recordable CDs and toner masks
    • Lowinsohn D., Richter E.M., Angnes L., Bertotti M. Disposable gold electrodes with reproducible area using recordable CDs and toner masks. Electroanalysis 2006, 18:89-94.
    • (2006) Electroanalysis , vol.18 , pp. 89-94
    • Lowinsohn, D.1    Richter, E.M.2    Angnes, L.3    Bertotti, M.4
  • 12
    • 0034961041 scopus 로고    scopus 로고
    • Compact disks, a new source for gold electrodes. Application to the quantification of copper by PSA
    • Richter E.M., Augelli M.A., Magarotto S., Angnes L. Compact disks, a new source for gold electrodes. Application to the quantification of copper by PSA. Electroanalysis 2001, 13:760-764.
    • (2001) Electroanalysis , vol.13 , pp. 760-764
    • Richter, E.M.1    Augelli, M.A.2    Magarotto, S.3    Angnes, L.4
  • 13
    • 0000808336 scopus 로고    scopus 로고
    • Gold electrodes from recordable CDs for mercury quantification by flow injection analysis
    • Richter E.M., Augelli M.A., Kume G.H., Mioshi R.N., Angnes L. Gold electrodes from recordable CDs for mercury quantification by flow injection analysis. Fresenius J. Anal. Chem. 2000, 366:444-448.
    • (2000) Fresenius J. Anal. Chem. , vol.366 , pp. 444-448
    • Richter, E.M.1    Augelli, M.A.2    Kume, G.H.3    Mioshi, R.N.4    Angnes, L.5
  • 14
    • 33646558230 scopus 로고    scopus 로고
    • Determination of Se(IV) by anodic stripping voltammetry using gold electrodes made from recordable CDs
    • Pereira C.F., Gonzaga F.B., Guaritá-Santos A.M., Souza J.R. Determination of Se(IV) by anodic stripping voltammetry using gold electrodes made from recordable CDs. Talanta 2006, 69:877-881.
    • (2006) Talanta , vol.69 , pp. 877-881
    • Pereira, C.F.1    Gonzaga, F.B.2    Guaritá-Santos, A.M.3    Souza, J.R.4
  • 17
  • 18
    • 20944432304 scopus 로고    scopus 로고
    • Nanomaterials in analytical chemistry
    • Martin C.R., Mitchell D.T. Nanomaterials in analytical chemistry. Anal. Chem. 1998, 70:322-327.
    • (1998) Anal. Chem. , vol.70 , pp. 322-327
    • Martin, C.R.1    Mitchell, D.T.2
  • 19
    • 0032029417 scopus 로고    scopus 로고
    • FTIR/ATR for protein adsorption to biomaterial surfaces
    • Chittur K.K. FTIR/ATR for protein adsorption to biomaterial surfaces. Biomaterials 1998, 19:357-369.
    • (1998) Biomaterials , vol.19 , pp. 357-369
    • Chittur, K.K.1
  • 22
    • 71549126604 scopus 로고    scopus 로고
    • Layered surface acoustic wave chemical and bio-sensors
    • American Scientific Publishers, Pennsylvania, C.A. Grimes, E.C. Dickey, M.V. Pishko (Eds.)
    • Powell D.A., Kalantar-Zadeh K., Wlodarski W., Ippolito S.J. Layered surface acoustic wave chemical and bio-sensors. Encyclopedia of Sensors 2006, 1-18. American Scientific Publishers, Pennsylvania. C.A. Grimes, E.C. Dickey, M.V. Pishko (Eds.).
    • (2006) Encyclopedia of Sensors , pp. 1-18
    • Powell, D.A.1    Kalantar-Zadeh, K.2    Wlodarski, W.3    Ippolito, S.J.4
  • 23
    • 0043269702 scopus 로고    scopus 로고
    • Probing biomolecular interactions at conductive and semiconductive surfaces by impedance spectroscopy: routes to impedimetric immunosensors, DNA-sensors, and enzyme biosensors
    • Katz E., Willner I. Probing biomolecular interactions at conductive and semiconductive surfaces by impedance spectroscopy: routes to impedimetric immunosensors, DNA-sensors, and enzyme biosensors. Electroanalysis 2003, 15:913-947.
    • (2003) Electroanalysis , vol.15 , pp. 913-947
    • Katz, E.1    Willner, I.2
  • 24
    • 70349088554 scopus 로고    scopus 로고
    • A novel, label-free immunosensor for the detection of α-fetoprotein using functionalised gold nanoparticles
    • Liang W., Yi W., Li S., Yuan R., Chen A., Chen S., Xiang G., Hu C. A novel, label-free immunosensor for the detection of α-fetoprotein using functionalised gold nanoparticles. Clin. Biochem. 2009, 42:1524-1530.
    • (2009) Clin. Biochem. , vol.42 , pp. 1524-1530
    • Liang, W.1    Yi, W.2    Li, S.3    Yuan, R.4    Chen, A.5    Chen, S.6    Xiang, G.7    Hu, C.8
  • 25
    • 41449091313 scopus 로고    scopus 로고
    • Electrochemical impedance immunosensor based on three-dimensionally ordered macroporous gold film
    • Chen X.J., Wang Y.Y., Zhou J.J., Yan W., Li X., Zhu J.J. Electrochemical impedance immunosensor based on three-dimensionally ordered macroporous gold film. Anal. Chem. 2008, 80:2133-2140.
    • (2008) Anal. Chem. , vol.80 , pp. 2133-2140
    • Chen, X.J.1    Wang, Y.Y.2    Zhou, J.J.3    Yan, W.4    Li, X.5    Zhu, J.J.6
  • 26
    • 0345731216 scopus 로고    scopus 로고
    • A protein A-based orientation-controlled immobilization strategy for antibodies using nanometer-sized gold particles and plasma-polymerized film
    • Wang H., Liu Y., Yang Y., Deng T., Shen G., Yu R. A protein A-based orientation-controlled immobilization strategy for antibodies using nanometer-sized gold particles and plasma-polymerized film. Anal. Biochem. 2004, 324:219-226.
    • (2004) Anal. Biochem. , vol.324 , pp. 219-226
    • Wang, H.1    Liu, Y.2    Yang, Y.3    Deng, T.4    Shen, G.5    Yu, R.6
  • 28
    • 23744474242 scopus 로고    scopus 로고
    • Recognition of dengue virus protein using epitope-mediated molecularly imprinted film
    • Tai D-F., Lin C-Y., Wu T-Z., Chen L-K. Recognition of dengue virus protein using epitope-mediated molecularly imprinted film. Anal. Chem. 2006, 77:5140-5143.
    • (2006) Anal. Chem. , vol.77 , pp. 5140-5143
    • Tai, D.-F.1    Lin, C.-Y.2    Wu, T.-Z.3    Chen, L.-K.4
  • 30
    • 4344691618 scopus 로고    scopus 로고
    • Multi-analyte single-membrane biosensor for the serotype-specific detection of dengue virus
    • Zaytseva N.V., Montagna R.A., Lee E.M., Baeumner A.J. Multi-analyte single-membrane biosensor for the serotype-specific detection of dengue virus. Anal. Bioanal. Chem. 2004, 380:46-53.
    • (2004) Anal. Bioanal. Chem. , vol.380 , pp. 46-53
    • Zaytseva, N.V.1    Montagna, R.A.2    Lee, E.M.3    Baeumner, A.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.