-
1
-
-
0026652804
-
Evaluation of risk factors for laryngeal edema after tracheal extubation in adults and its prevention by dexamethasone. A placebo-controlled, double blind, multicenter study
-
Darmon JY, Rauss A, Dreyfuss D, Bleichner G, Elkharrat D, Schlemmer B, et al. Evaluation of risk factors for laryngeal edema after tracheal extubation in adults and its prevention by dexamethasone. A placebo-controlled, double blind, multicenter study. Anesthesiology 1992; 77: 245-51.
-
(1992)
Anesthesiology
, vol.77
, pp. 245-251
-
-
Darmon, J.Y.1
Rauss, A.2
Dreyfuss, D.3
Bleichner, G.4
Elkharrat, D.5
Schlemmer, B.6
-
2
-
-
0027480230
-
Prolonged intubation injuries of the larynx: Endoscopic diagnosis, classification, and treatment
-
Benjamin B. Prolonged intubation injuries of the larynx: endoscopic diagnosis, classification, and treatment. Ann Otol Rhinol Laryngol Suppl 1993; 160: 1-15.
-
(1993)
Ann Otol Rhinol Laryngol Suppl
, vol.160
, pp. 1-15
-
-
Benjamin, B.1
-
3
-
-
0037277740
-
Post-extubation stridor in intensive care unit patients. Risk factors evaluation and importance of the cuff-leak test
-
Jaber S, Chanques G, Matecki S, Ramonatxo M, Vergne C, Souche B, et al. Post-extubation stridor in intensive care unit patients. Risk factors evaluation and importance of the cuff-leak test. Intensive Care Med 2003; 29: 69-74.
-
(2003)
Intensive Care Med
, vol.29
, pp. 69-74
-
-
Jaber, S.1
Chanques, G.2
Matecki, S.3
Ramonatxo, M.4
Vergne, C.5
Souche, B.6
-
4
-
-
34247154788
-
The role of the cuff leak test in predicting the effects of corticosteroid treatment on postextubation stridor
-
Wang CL, Tsai YH, Huang CC, Wu YK, Ye MZ, Chou HM, et al. The role of the cuff leak test in predicting the effects of corticosteroid treatment on postextubation stridor. Chang Gung Med J 2007; 30: 53-61.
-
(2007)
Chang Gung Med J
, vol.30
, pp. 53-61
-
-
Wang, C.L.1
Tsai, Y.H.2
Huang, C.C.3
Wu, Y.K.4
Ye, M.Z.5
Chou, H.M.6
-
5
-
-
0036037662
-
The cuff leak test to predict failure of tracheal extubation for laryngeal edema
-
De Bast Y, De Backer D, Moraine JJ, Lemaire M, Vandenborght C, Vincent JL. The cuff leak test to predict failure of tracheal extubation for laryngeal edema. Intensive Care Med 2002; 28: 1267-72.
-
(2002)
Intensive Care Med
, vol.28
, pp. 1267-1272
-
-
de Bast, Y.1
de Backer, D.2
Moraine, J.J.3
Lemaire, M.4
Vandenborght, C.5
Vincent, J.L.6
-
6
-
-
0031870334
-
Independent effects of etiology of failure and time to reintubation on outcome for patients failing extubation
-
Epstein SK, Ciubotaru RL. Independent effects of etiology of failure and time to reintubation on outcome for patients failing extubation. Am J Respir Crit Care Med 1998; 158: 489-93.
-
(1998)
Am J Respir Crit Care Med
, vol.158
, pp. 489-493
-
-
Epstein, S.K.1
Ciubotaru, R.L.2
-
7
-
-
0023917741
-
Incidence and morbidity of extubation failure in surgical intensive care patients
-
Demling RH, Read T, Lind LJ, Flanagan HL. Incidence and morbidity of extubation failure in surgical intensive care patients. Crit Care Med 1988; 16: 573-7.
-
(1988)
Crit Care Med
, vol.16
, pp. 573-577
-
-
Demling, R.H.1
Read, T.2
Lind, L.J.3
Flanagan, H.L.4
-
8
-
-
0024059008
-
Cuff test for safe extubation following laryngeal edema
-
Potgieter PD, Hammond JM. "Cuff" test for safe extubation following laryngeal edema. Crit Care Med 1988; 16: 818.
-
(1988)
Crit Care Med
, vol.16
, pp. 818
-
-
Potgieter, P.D.1
Hammond, J.M.2
-
9
-
-
0031050755
-
Endoscopic evolution of laryngeal injuries caused by translaryngeal intubation
-
Vila J, Bosque MD, Garcia M, Palomar M, Quesada P, Ramis B. Endoscopic evolution of laryngeal injuries caused by translaryngeal intubation. Eur Arch Otorhinolaryngol 1997; 254 (Suppl 1): S97-100.
-
(1997)
Eur Arch Otorhinolaryngol
, vol.254
, Issue.1 SUPPL.
, pp. 97-100
-
-
Vila, J.1
Bosque, M.D.2
Garcia, M.3
Palomar, M.4
Quesada, P.5
Ramis, B.6
-
10
-
-
0033856183
-
The utility of three-dimensional computed tomography in unanticipated difficult endotracheal intubation
-
Kanaya N, Kawana S, Watanabe H, Niiyama Y, Niiya T, Nakayama M, et al. The utility of three-dimensional computed tomography in unanticipated difficult endotracheal intubation. Anesth Analg 2000; 91: 752-4.
-
(2000)
Anesth Analg
, vol.91
, pp. 752-754
-
-
Kanaya, N.1
Kawana, S.2
Watanabe, H.3
Niiyama, Y.4
Niiya, T.5
Nakayama, M.6
-
11
-
-
0023220758
-
When to extubate the croup patient: The "leak" test
-
Adderley RJ, Mullins GC. When to extubate the croup patient: the "leak" test. Can J Anaesth 1987; 34: 304-6.
-
(1987)
Can J Anaesth
, vol.34
, pp. 304-306
-
-
Adderley, R.J.1
Mullins, G.C.2
-
12
-
-
0029909694
-
Association between reduced cuff leak volume and postextubation stridor
-
Miller RL, Cole RP. Association between reduced cuff leak volume and postextubation stridor. Chest 1996; 110: 1035-40.
-
(1996)
Chest
, vol.110
, pp. 1035-1040
-
-
Miller, R.L.1
Cole, R.P.2
-
13
-
-
33644874217
-
The endotracheal tube cuff-leak test as a predictor for postextubation stridor
-
Kriner EJ, Shafazand S, Colice GL. The endotracheal tube cuff-leak test as a predictor for postextubation stridor. Respir Care 2005; 50: 1632-8.
-
(2005)
Respir Care
, vol.50
, pp. 1632-1638
-
-
Kriner, E.J.1
Shafazand, S.2
Colice, G.L.3
-
14
-
-
0034041442
-
Measurement of endotracheal tube cuff leak to predict postextubation stridor and need for reintubation
-
Sandhu RS, Pasquale MD, Miller K, Wasser TE. Measurement of endotracheal tube cuff leak to predict postextubation stridor and need for reintubation. J Am Coll Surg 2000; 190: 682-7.
-
(2000)
J Am Coll Surg
, vol.190
, pp. 682-687
-
-
Sandhu, R.S.1
Pasquale, M.D.2
Miller, K.3
Wasser, T.E.4
-
15
-
-
0027946332
-
Comparison of three methods of gradual withdrawal from ventilatory support during weaning from mechanical ventilation
-
Brochard L, Rauss A, Benito S, Conti G, Mancebo J, Rekik N, et al. Comparison of three methods of gradual withdrawal from ventilatory support during weaning from mechanical ventilation. Am J Respir Crit Care Med 1994; 150: 896-903.
-
(1994)
Am J Respir Crit Care Med
, vol.150
, pp. 896-903
-
-
Brochard, L.1
Rauss, A.2
Benito, S.3
Conti, G.4
Mancebo, J.5
Rekik, N.6
-
16
-
-
0028797262
-
A comparison of four methods of weaning patients from mechanical ventilation. Spanish Lung Failure Collaborative Group
-
Esteban A, Frutos F, Tobin MJ, Alia I, Solsona JF, Valverdu I, et al. A comparison of four methods of weaning patients from mechanical ventilation. Spanish Lung Failure Collaborative Group. N Engl J Med 1995; 332: 345-50.
-
(1995)
N Engl J Med
, vol.332
, pp. 345-350
-
-
Esteban, A.1
Frutos, F.2
Tobin, M.J.3
Alia, I.4
Solsona, J.F.5
Valverdu, I.6
-
17
-
-
0026776024
-
Use of the Blasius resistance formula to estimate the effective diameter of endotracheal tubes
-
Lofaso F, Louis B, Brochard L, Harf A, Isabey D. Use of the Blasius resistance formula to estimate the effective diameter of endotracheal tubes. Am Rev Respir Dis 1992; 146: 974-9.
-
(1992)
Am Rev Respir Dis
, vol.146
, pp. 974-979
-
-
Lofaso, F.1
Louis, B.2
Brochard, L.3
Harf, A.4
Isabey, D.5
|