메뉴 건너뛰기




Volumn 50, Issue 12, 2005, Pages 1632-1638

The endotracheal tube cuff-leak test as a predictor for postextubation stridor

Author keywords

Airway obstruction; Endotracheal tube cuff; Extubation failure; Laryngeal edema; Stridor; Tracheal intubation

Indexed keywords

ACCURACY; ADULT; ARTICLE; ARTIFICIAL VENTILATION; CONTROLLED STUDY; CUFF LEAK TEST; ENDOTRACHEAL INTUBATION; ENDOTRACHEAL TUBE; EXTUBATION; FEMALE; FUNCTION TEST; HUMAN; INTENSIVE CARE UNIT; MAJOR CLINICAL STUDY; MALE; OBSERVATIONAL STUDY; PREDICTION AND FORECASTING; PREDICTOR VARIABLE; PROSPECTIVE STUDY; QUALITY CONTROL; SENSITIVITY AND SPECIFICITY; STRIDOR; TREATMENT OUTCOME; ABNORMAL RESPIRATORY SOUND; AGED; INSTRUMENTATION; LARYNX; LUNG FUNCTION TEST; MIDDLE AGED; PATHOLOGY; PATHOPHYSIOLOGY; REPRODUCIBILITY; RESPIRATORY FAILURE; TIDAL VOLUME; TIME;

EID: 33644874217     PISSN: 00201324     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (83)

References (18)
  • 1
    • 0024325955 scopus 로고
    • Laryngeal complications of prolonged intubation
    • Colice G, Stuckel T, Dain B. Laryngeal complications of prolonged intubation. Chest 1989;96(4):877-884.
    • (1989) Chest , vol.96 , Issue.4 , pp. 877-884
    • Colice, G.1    Stuckel, T.2    Dain, B.3
  • 3
    • 0030004282 scopus 로고    scopus 로고
    • The cuff-leak test as a predictor of postextubation stridor: A prospective study
    • Marik PE. The cuff-leak test as a predictor of postextubation stridor: a prospective study. Respir Care 1996;41(6):509-511.
    • (1996) Respir Care , vol.41 , Issue.6 , pp. 509-511
    • Marik, P.E.1
  • 4
    • 0029909694 scopus 로고    scopus 로고
    • Association between reduced cuff-leak volume and postextubation stridor
    • Miller R, Cole R. Association between reduced cuff-leak volume and postextubation stridor. Chest 1996;110(4):1035-1040.
    • (1996) Chest , vol.110 , Issue.4 , pp. 1035-1040
    • Miller, R.1    Cole, R.2
  • 5
    • 0026516576 scopus 로고
    • The 'cuff-leak' test for extubation
    • Fisher MM, Raper RF. The 'cuff-leak' test for extubation. Anesthesia 1992;47(1):10-12.
    • (1992) Anesthesia , vol.47 , Issue.1 , pp. 10-12
    • Fisher, M.M.1    Raper, R.F.2
  • 6
    • 0026652804 scopus 로고
    • Evaluation of risk factors for laryngeal edema after tracheal extubation in adults and its prevention by dexamethasone
    • Darmon JY, Rauss A, Dreyfuss D, Bleichner G, Elkharrat D, Schlemmer B, et al. Evaluation of risk factors for laryngeal edema after tracheal extubation in adults and its prevention by dexamethasone. Anesthesiology 1992;77(2):245-251.
    • (1992) Anesthesiology , vol.77 , Issue.2 , pp. 245-251
    • Darmon, J.Y.1    Rauss, A.2    Dreyfuss, D.3    Bleichner, G.4    Elkharrat, D.5    Schlemmer, B.6
  • 7
    • 0025757163 scopus 로고
    • Predictors of postextubation stridor in pediatric trauma patients
    • Kemper K, Benson M, Bishop M. Predictors of postextubation stridor in pediatric trauma patients. Crit Care Med 1991;19(3):352-355.
    • (1991) Crit Care Med , vol.19 , Issue.3 , pp. 352-355
    • Kemper, K.1    Benson, M.2    Bishop, M.3
  • 8
    • 0029800620 scopus 로고    scopus 로고
    • Postextubation laryngeal edema in adults: Risk factor evaluation and prevention by hydrocortisone
    • Ho LI, Harn HJ, Lien TC, Hu PY, Wang JH. Postextubation laryngeal edema in adults: risk factor evaluation and prevention by hydrocortisone. Intensive Care Med 1996;22(9):933-936.
    • (1996) Intensive Care Med , vol.22 , Issue.9 , pp. 933-936
    • Ho, L.I.1    Harn, H.J.2    Lien, T.C.3    Hu, P.Y.4    Wang, J.H.5
  • 9
    • 0024724591 scopus 로고
    • Routine use of dexamethasone for the prevention of postextubation respiratory distress
    • Ferrara TB, Georgieff MK, Ebert J, Fisher JB. Routine use of dexamethasone for the prevention of postextubation respiratory distress. J Perinat 1989;9(3):287-290.
    • (1989) J Perinat , vol.9 , Issue.3 , pp. 287-290
    • Ferrara, T.B.1    Georgieff, M.K.2    Ebert, J.3    Fisher, J.B.4
  • 11
    • 0034041442 scopus 로고    scopus 로고
    • Measurement of endotracheal tube cuff leak to predict postextubation stridor and need for reintubation
    • Sandhu RS, Pasquale MD, Miller K, Wasser TE. Measurement of endotracheal tube cuff leak to predict postextubation stridor and need for reintubation. J Am Coll Surg 2000;190(6):682-687.
    • (2000) J Am Coll Surg , vol.190 , Issue.6 , pp. 682-687
    • Sandhu, R.S.1    Pasquale, M.D.2    Miller, K.3    Wasser, T.E.4
  • 12
    • 0029993897 scopus 로고    scopus 로고
    • Dexamethasone for the prevention of postextubation airway obstruction: A prospective, randomized, double-blind, placebo-controlled trial
    • Anene O, Meert KL, Uy H, Simpson P, Sarnaik AP. Dexamethasone for the prevention of postextubation airway obstruction: a prospective, randomized, double-blind, placebo-controlled trial. Crit Care Med 1996;24(10):1666-1669.
    • (1996) Crit Care Med , vol.24 , Issue.10 , pp. 1666-1669
    • Anene, O.1    Meert, K.L.2    Uy, H.3    Simpson, P.4    Sarnaik, A.P.5
  • 13
    • 0023220758 scopus 로고
    • When to extubate the croup patient: The "leak" test
    • Adderley RJ, Mullins GC. When to extubate the croup patient: the "leak" test. Can J Anesth 1987;34(3 Pt 1):304-306.
    • (1987) Can J Anesth , vol.34 , Issue.3 PART 1 , pp. 304-306
    • Adderley, R.J.1    Mullins, G.C.2
  • 14
    • 0032742711 scopus 로고    scopus 로고
    • Evaluation of the cuff-leak test in a cardiac surgery population
    • Engoren M. Evaluation of the cuff-leak test in a cardiac surgery population. Chest 1999;116(4):1029-1031.
    • (1999) Chest , vol.116 , Issue.4 , pp. 1029-1031
    • Engoren, M.1
  • 15
    • 0019957204 scopus 로고
    • Glottis narrowing in lung disease
    • Higenbottam T, Payne J. Glottis narrowing in lung disease. Am Rev Respir Dis 1982;125(6):746-750.
    • (1982) Am Rev Respir Dis , vol.125 , Issue.6 , pp. 746-750
    • Higenbottam, T.1    Payne, J.2
  • 16
    • 0022500965 scopus 로고
    • The use of relative operating characteristic (ROC) curves in test performance evaluation
    • Beck JR, Shultz EK. The use of relative operating characteristic (ROC) curves in test performance evaluation. Arch Pathol Lab Med 1986;110(1):13-20.
    • (1986) Arch Pathol Lab Med , vol.110 , Issue.1 , pp. 13-20
    • Beck, J.R.1    Shultz, E.K.2
  • 17
    • 0005314988 scopus 로고    scopus 로고
    • Refining probability: An introduction to the use of diagnostic tests
    • Friedland DJ, editor, Stamford, Connecticut: Appleton and Lang;
    • Go AS. Refining probability: an introduction to the use of diagnostic tests. In: Friedland DJ, editor. Evidence based medicine: a framework for clinical practice. Stamford, Connecticut: Appleton and Lang; 1998:11-33.
    • (1998) Evidence based medicine: A framework for clinical practice , pp. 11-33
    • Go, A.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.