메뉴 건너뛰기




Volumn 26, Issue 3, 2011, Pages 598-606

Comparison of ball and telescopic crown attachments in implant-retained mandibular overdentures: A 5-year prospective study

Author keywords

Ball anchors; Implant retained prostheses; Mandibular overdentures; Prosthodontic maintenance; Telescopic crowns

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DENTAL SURGERY; DENTURE; EDENTULOUSNESS; FEMALE; HEALTH SURVEY; HUMAN; INSTRUMENTATION; LONGITUDINAL STUDY; MALE; MANDIBLE; METHODOLOGY; MIDDLE AGED; NONPARAMETRIC TEST; ORAL SURGERY; PROSPECTIVE STUDY; RANDOMIZED CONTROLLED TRIAL; TOOTH IMPLANTATION; TOOTH PROSTHESIS; TREATMENT OUTCOME; WEIGHT BEARING;

EID: 84863895772     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (55)

References (48)
  • 1
    • 0035513668 scopus 로고    scopus 로고
    • Mandibular implant-retained overdentures:A literature review
    • Sadowsky SJ. Mandibular implant-retained overdentures:A literature review. J Prosthet Dent 2001;86:468-473.
    • (2001) J Prosthet Dent , vol.86 , pp. 468-473
    • Sadowsky, S.J.1
  • 2
    • 0032017010 scopus 로고    scopus 로고
    • Implant-supported overdentures:A longitudinal prospective study
    • Bergendal T, Engquist B. Implant-supported overdentures:A longitudinal prospective study. Int J Oral Maxillofac Implants 1998;13:253-262.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 253-262
    • Bergendal, T.1    Engquist, B.2
  • 3
    • 0347418232 scopus 로고    scopus 로고
    • Comparison of implant-retained mandibular overdentures and conventional complete dentures: A 10-year prospective study of clinical aspects and patients satisfaction
    • Meijer HJ, Raghoebar GM, Van’t Hof MA. Comparison of implant-retained mandibular overdentures and conventional complete dentures: A 10-year prospective study of clinical aspects and patients satisfaction. Int J Oral Maxillofac Implants 2003;18:879-885.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 879-885
    • Meijer, H.J.1    Raghoebar, G.M.2    Van’t Hof, M.A.3
  • 4
    • 50849088639 scopus 로고    scopus 로고
    • Five-year prospective evaluation of mandibular overdentures retained by two microthreaded, TiOblast nonsplinted implants and retentive ball anchors
    • Cooper LF, Moriarty JD, Guckes AD, et al. Five-year prospective evaluation of mandibular overdentures retained by two microthreaded, TiOblast nonsplinted implants and retentive ball anchors. Int J Oral Maxillofac Implants 2008;23:696-704.
    • (2008) Int J Oral Maxillofac Implants , vol.23 , pp. 696-704
    • Cooper, L.F.1    Moriarty, J.D.2    Guckes, A.D.3
  • 5
    • 4344673619 scopus 로고    scopus 로고
    • Long-term treatment outcomes in edentulous patients with implant overdentures: The Toronto study
    • Attard NJ, Zarb GA. Long-term treatment outcomes in edentulous patients with implant overdentures: The Toronto study. Int J Prosthodont 2004;17:425-433.
    • (2004) Int J Prosthodont , vol.17 , pp. 425-433
    • Attard, N.J.1    Zarb, G.A.2
  • 6
    • 7244260317 scopus 로고    scopus 로고
    • A 10-year randomized clinical trial on the influence of splinted and unsplinted oral implants retaining mandibular overdentures:Peri-implant outcome
    • Naert I, Alsaadi G, van Steenberghe D, Quirynen M. A 10-year randomized clinical trial on the influence of splinted and unsplinted oral implants retaining mandibular overdentures:Peri-implant outcome. Int J Oral Maxillofac Implants 2004;19:695-702.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 695-702
    • Naert, I.1    Alsaadi, G.2    van Steenberghe, D.3    Quirynen, M.4
  • 7
    • 0031203252 scopus 로고    scopus 로고
    • Patient satisfaction with implant-supported mandibular overdentures:A comparison of three treatment strategies with ITI dental implants
    • Wismeijer D, van Waas MA, Vermeeren JI, Mulder J, Kalk W. Patient satisfaction with implant-supported mandibular overdentures:A comparison of three treatment strategies with ITI dental implants. Int J Oral Maxillofac Surg 1997;26:263-267.
    • (1997) Int J Oral Maxillofac Surg , vol.26 , pp. 263-267
    • Wismeijer, D.1    van Waas, M.A.2    Vermeeren, J.I.3    Mulder, J.4    Kalk, W.5
  • 8
    • 0141739548 scopus 로고    scopus 로고
    • Oral health status and treatment satisfaction with mandibular implant overdentures and conventional dentures: A randomized clinical trial in a senior population
    • Awad MA, Lund JP, Shapiro SH, et al. Oral health status and treatment satisfaction with mandibular implant overdentures and conventional dentures: A randomized clinical trial in a senior population. Int J Prosthodont 2003;16:390-396.
    • (2003) Int J Prosthodont , vol.16 , pp. 390-396
    • Awad, M.A.1    Lund, J.P.2    Shapiro, S.H.3
  • 10
    • 0037812282 scopus 로고    scopus 로고
    • Comparing the efficacy of mandibular implant-retained overdentures and conventional dentures among middle-aged edentulous patients: Satisfaction and functional assessment
    • Awad MA, Lund JP, Dufresne E, Feine JS. Comparing the efficacy of mandibular implant-retained overdentures and conventional dentures among middle-aged edentulous patients: Satisfaction and functional assessment. Int J Prosthodont 2003;16:117-122.
    • (2003) Int J Prosthodont , vol.16 , pp. 117-122
    • Awad, M.A.1    Lund, J.P.2    Dufresne, E.3    Feine, J.S.4
  • 11
    • 0036719424 scopus 로고    scopus 로고
    • The McGill consensus statement on overdenture. Mandibular 2-implant overdentures as first choice standard of care for edentulous patients
    • Thomason JM. The McGill consensus statement on overdenture. Mandibular 2-implant overdentures as first choice standard of care for edentulous patients. Eur J Prosthodont Restorative Dent 2002;10:95-96.
    • (2002) Eur J Prosthodont Restorative Dent , vol.10 , pp. 95-96
    • Thomason, J.M.1
  • 12
    • 0032109199 scopus 로고    scopus 로고
    • Treatment concept for mandibular overdentures supported by endosseous implants: A literature review
    • Batenburg RH, Meijer HJ, Raghoebar GM, Vissink A. Treatment concept for mandibular overdentures supported by endosseous implants: A literature review. Int J Oral Maxillofac Implants 1998;13:539-545.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 539-545
    • Batenburg, R.H.1    Meijer, H.J.2    Raghoebar, G.M.3    Vissink, A.4
  • 13
    • 4444221739 scopus 로고    scopus 로고
    • An eight-year follow-up to a randomized clinical trial of participant satisfaction with three types of mandibular implant-retained overdentures
    • Timmerman R, Stoker GT, Wismeijer D, Oosterveld P, Vermeeren JI, van Waas MA. An eight-year follow-up to a randomized clinical trial of participant satisfaction with three types of mandibular implant-retained overdentures. J Dent Res 2004;83:630-633.
    • (2004) J Dent Res , vol.83 , pp. 630-633
    • Timmerman, R.1    Stoker, G.T.2    Wismeijer, D.3    Oosterveld, P.4    Vermeeren, J.I.5    van Waas, M.A.6
  • 14
    • 0032083031 scopus 로고    scopus 로고
    • A 5-year randomized clinical trial on the influence of splinted and unsplinted oral implants in the mandibular overdenture therapy. Part I: Per-implant outcome
    • Naert I, Gizani S, Vuylsteke M, van Steenberghe D. A 5-year randomized clinical trial on the influence of splinted and unsplinted oral implants in the mandibular overdenture therapy. Part I: Per-implant outcome. Clin Oral Implants Res 1998;9:170-177.
    • (1998) Clin Oral Implants Res , vol.9 , pp. 170-177
    • Naert, I.1    Gizani, S.2    Vuylsteke, M.3    van Steenberghe, D.4
  • 15
    • 0033087984 scopus 로고    scopus 로고
    • A 5-year prospective randomized clinical trial on the influence of splinted and unsplinted oral implants retaining a mandibular overdenture: Prosthetic aspects and patients satisfaction
    • Naert I, Gizani S, Vuylsteke M, van Steenberghe D. A 5-year prospective randomized clinical trial on the influence of splinted and unsplinted oral implants retaining a mandibular overdenture: Prosthetic aspects and patients satisfaction. J Oral Rehabil 1999;26:195-202.
    • (1999) J Oral Rehabil , vol.26 , pp. 195-202
    • Naert, I.1    Gizani, S.2    Vuylsteke, M.3    van Steenberghe, D.4
  • 16
    • 0347481241 scopus 로고    scopus 로고
    • Retention and postinsertion maintenance of bar-clip, ball and magnet attachments in mandibular implant overdenture treatment:An in vivo comparsison after 3 months of function
    • van Kampen F, Cune M, van der Bilt, Bosman F. Retention and postinsertion maintenance of bar-clip, ball and magnet attachments in mandibular implant overdenture treatment:An in vivo comparsison after 3 months of function. Clin Oral Implants Res 2003;14:720-726.
    • (2003) Clin Oral Implants Res , vol.14 , pp. 720-726
    • van Kampen, F.1    Cune, M.2    van der Bilt, B.F.3
  • 17
    • 17144363947 scopus 로고    scopus 로고
    • Patient satisfaction and preference with magnet, bar-clip, and ballsocket retained mandibular implant overdentures: A crossover clinical trial
    • Cune M, van Kampen F, van der Bilt A, Bosman F. Patient satisfaction and preference with magnet, bar-clip, and ballsocket retained mandibular implant overdentures: A crossover clinical trial. Int J Prosthodont 2005;18:99-105.
    • (2005) Int J Prosthodont , vol.18 , pp. 99-105
    • Cune, M.1    van Kampen, F.2    van der Bilt, A.3    Bosman, F.4
  • 18
    • 0034189421 scopus 로고    scopus 로고
    • Mandibular implant-supported overdentures: A prospective evaluation of the burden of prosthodontic maintenance with 3 different attachment systems
    • Payne AG, Solomons YF. Mandibular implant-supported overdentures: A prospective evaluation of the burden of prosthodontic maintenance with 3 different attachment systems. Int J Prothodont 2000;13:246-253.
    • (2000) Int J Prothodont , vol.13 , pp. 246-253
    • Payne, A.G.1    Solomons, Y.F.2
  • 19
    • 11144233686 scopus 로고    scopus 로고
    • A clinical trial of patients satisfaction and prosthodontic needs with ball and bar attachments for implant-retained complete overdentures:Three-year results
    • MacEntee MI, Walton JN, Glick N. A clinical trial of patients satisfaction and prosthodontic needs with ball and bar attachments for implant-retained complete overdentures:Three-year results. J Prosthet Dent 2005;93:28-37.
    • (2005) J Prosthet Dent , vol.93 , pp. 28-37
    • MacEntee, M.I.1    Walton, J.N.2    Glick, N.3
  • 20
    • 0035239842 scopus 로고    scopus 로고
    • The outcome of implant overdentures from a prosthodontic perspective:Proposal for a classification protocol
    • Payne AG, Walton TR, Walton JN, Solomons YF. The outcome of implant overdentures from a prosthodontic perspective:Proposal for a classification protocol. Int J Prosthodont 2001;14:27-43.
    • (2001) Int J Prosthodont , vol.14 , pp. 27-43
    • Payne, A.G.1    Walton, T.R.2    Walton, J.N.3    Solomons, Y.F.4
  • 21
    • 0031216650 scopus 로고    scopus 로고
    • A prospective study on the maintenance of implant prostheses in private practice
    • Walton JN, MacEntee MI. A prospective study on the maintenance of implant prostheses in private practice. Int J Prosthodont 1997;5:453-458.
    • (1997) Int J Prosthodont , vol.5 , pp. 453-458
    • Walton, J.N.1    MacEntee, M.I.2
  • 22
    • 0033122044 scopus 로고    scopus 로고
    • Mandibular overdentures stabilized by Astra Tech implants with either ball attachments or magnets:5-year results
    • Davis DM, Packer ME. Mandibular overdentures stabilized by Astra Tech implants with either ball attachments or magnets:5-year results. Int J Prosthodont 1999;12:222-229.
    • (1999) Int J Prosthodont , vol.12 , pp. 222-229
    • Davis, D.M.1    Packer, M.E.2
  • 23
    • 0034157335 scopus 로고    scopus 로고
    • Implant-supported mandibular overdentures retained with ball or bar attachments: A randomized prospective 5-year study
    • Gotfredsen K, Holm B. Implant-supported mandibular overdentures retained with ball or bar attachments: A randomized prospective 5-year study. Int J Prosthodont 2000;13:125-130.
    • (2000) Int J Prosthodont , vol.13 , pp. 125-130
    • Gotfredsen, K.1    Holm, B.2
  • 24
    • 0035351334 scopus 로고    scopus 로고
    • Clinical longevity of removable partial dentures retained by telescopic crowns:Outcome of the double crown with clearance fit
    • Wenz HJ, Hertrampf K, Lehmann KM. Clinical longevity of removable partial dentures retained by telescopic crowns:Outcome of the double crown with clearance fit. Int J Prosthodont 2001;14:207-213.
    • (2001) Int J Prosthodont , vol.14 , pp. 207-213
    • Wenz, H.J.1    Hertrampf, K.2    Lehmann, K.M.3
  • 25
    • 0032200418 scopus 로고    scopus 로고
    • A telescopic crown concept for the restoration of the partially edentulous arch: The Marburg double crown system
    • Wenz HJ, Lehmann KM. A telescopic crown concept for the restoration of the partially edentulous arch: The Marburg double crown system. Int J Prosthodont 1998;11:541-550.
    • (1998) Int J Prosthodont , vol.11 , pp. 541-550
    • Wenz, H.J.1    Lehmann, K.M.2
  • 26
    • 0035653714 scopus 로고    scopus 로고
    • Overdenture attachment selection and the loading of implant and denture-bearing are. Part 1: In vivo verification of stereolithographic model
    • Heckmann SM, Winter M, Meyer M, Weber HP, Wichmann MG. Overdenture attachment selection and the loading of implant and denture-bearing are. Part 1: In vivo verification of stereolithographic model. Clin Oral Implants Res 2001;12:617-623.
    • (2001) Clin Oral Implants Res , vol.12 , pp. 617-623
    • Heckmann, S.M.1    Winter, M.2    Meyer, M.3    Weber, H.P.4    Wichmann, M.G.5
  • 27
    • 0035653643 scopus 로고    scopus 로고
    • Overdenture attachment selection and the loading of implant and denture-bearing are. Part 2: A methodical study using five types of attachment
    • Heckmann SM, Winter M, Meyer M, Weber HP, Wichmann MG. Overdenture attachment selection and the loading of implant and denture-bearing are. Part 2: A methodical study using five types of attachment. Clin Oral Implants Res 2001;12:640-647.
    • (2001) Clin Oral Implants Res , vol.12 , pp. 640-647
    • Heckmann, S.M.1    Winter, M.2    Meyer, M.3    Weber, H.P.4    Wichmann, M.G.5
  • 29
    • 33645688714 scopus 로고    scopus 로고
    • Implant-supported mandibular overdentures retained with ball or telescopic crown attachments: A 3-year prospective study
    • Krennmair G, Weinländer M, Krainhöfner M, Piehslinger E. Implant-supported mandibular overdentures retained with ball or telescopic crown attachments: A 3-year prospective study. Int J Prosthodont 2006;19:164-170.
    • (2006) Int J Prosthodont , vol.19 , pp. 164-170
    • Krennmair, G.1    Weinländer, M.2    Krainhöfner, M.3    Piehslinger, E.4
  • 30
    • 42149133120 scopus 로고    scopus 로고
    • Comparing bar and double-crown attachments in implantretained prosthethic reconstruction: A follow-up investigation
    • Eitner S, Schlegel A, Emeka N, Holst S, Will J, Hamel J. Comparing bar and double-crown attachments in implantretained prosthethic reconstruction: A follow-up investigation. Clin Oral Implants Res 2008;19:530-537.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 530-537
    • Eitner, S.1    Schlegel, A.2    Emeka, N.3    Holst, S.4    Will, J.5    Hamel, J.6
  • 31
    • 0023583441 scopus 로고
    • The microbiota associated with successful or failing osseointegrated titanium implants
    • Mombelli A, van Oosten MAC, Schurch E, Lang NP. The microbiota associated with successful or failing osseointegrated titanium implants. Oral Microbiol Immunol 1987;2:145-151.
    • (1987) Oral Microbiol Immunol , vol.2 , pp. 145-151
    • Mombelli, A.1    van Oosten, M.A.C.2    Schurch, E.3    Lang, N.P.4
  • 32
    • 75549115165 scopus 로고
    • Periodontal disease in pregnancy. I: Correlation between oral hygiene and periodontal condition
    • Löe H, Silness J. Periodontal disease in pregnancy. I: Correlation between oral hygiene and periodontal condition. Acta Odontol Scand 1963;21:533-551.
    • (1963) Acta Odontol Scand , vol.21 , pp. 533-551
    • Löe, H.1    Silness, J.2
  • 33
    • 0346327180 scopus 로고    scopus 로고
    • Visualmetric measurement of peri-implant bone defects on radiographs:A reliability study [in German]
    • Gomez-Roman G, d’ Hoedt B, Axmann D, Schulte W. Visualmetric measurement of peri-implant bone defects on radiographs:A reliability study [in German]. Z Zahnärztl Implantol 1999;12:104-109.
    • (1999) Z Zahnärztl Implantol , vol.12 , pp. 104-109
    • Gomez-Roman, G.1    d’ Hoedt, B.2    Axmann, D.3    Schulte, W.4
  • 34
    • 2442526473 scopus 로고    scopus 로고
    • Initial implant position determines the magnitude of crestal bone remodelling
    • Hartman GA, Cochran DL. Initial implant position determines the magnitude of crestal bone remodelling. J Periodontol 2004;75:572-577.
    • (2004) J Periodontol , vol.75 , pp. 572-577
    • Hartman, G.A.1    Cochran, D.L.2
  • 36
    • 47249134203 scopus 로고    scopus 로고
    • "Biologic width" and crestal bone remodelling with sintered poroussurfaced dental implants: A study in dogs
    • Deporter D, Al-Sayyed A, Pilliar RM, Valiquette N. "Biologic width" and crestal bone remodelling with sintered poroussurfaced dental implants: A study in dogs. Int J Oral Maxillofac Implants 2008;23:544-550.
    • (2008) Int J Oral Maxillofac Implants , vol.23 , pp. 544-550
    • Deporter, D.1    Al-Sayyed, A.2    Pilliar, R.M.3    Valiquette, N.4
  • 37
    • 0036725066 scopus 로고    scopus 로고
    • Cleansability of and patient satisfaction with implantretained overdentures: A retrospective comparison of two attachment methods
    • Ambard AJ, Fanchiang JC, Mueninghoff L, Dasanayake AP. Cleansability of and patient satisfaction with implantretained overdentures: A retrospective comparison of two attachment methods. J Am Dent Assoc 2002;133:1237-1242.
    • (2002) J Am Dent Assoc , vol.133 , pp. 1237-1242
    • Ambard, A.J.1    Fanchiang, J.C.2    Mueninghoff, L.3    Dasanayake, A.P.4
  • 38
    • 39049193267 scopus 로고    scopus 로고
    • Telescopic crowns as attachments for implant supported restorations: A case series
    • Hoffmann O, Beaumont C, Tatakis DN, Zafiropoulos GG. Telescopic crowns as attachments for implant supported restorations: A case series. J Oral Implantol 2006;32:291-299.
    • (2006) J Oral Implantol , vol.32 , pp. 291-299
    • Hoffmann, O.1    Beaumont, C.2    Tatakis, D.N.3    Zafiropoulos, G.G.4
  • 39
    • 0028390745 scopus 로고
    • Peri-implant mucosal aspects of ITI implants supporting overdentures. A five-year longitudinal study
    • Mericske-Stern R, Steinlin Schaffner T, Marti P, Geering AH. Peri-implant mucosal aspects of ITI implants supporting overdentures. A five-year longitudinal study. Clin Oral Implants Res 1994;5:9-18.
    • (1994) Clin Oral Implants Res , vol.5 , pp. 9-18
    • Mericske-Stern, R.1    Steinlin Schaffner, T.2    Marti, P.3    Geering, A.H.4
  • 40
    • 0036559323 scopus 로고    scopus 로고
    • Mandibular overdentures: Comparative evaluation of prosthodontic maintenance of three different implant systems during the first year of service
    • Watson GK, Payne AG, Purton DG, Thomson WM. Mandibular overdentures: Comparative evaluation of prosthodontic maintenance of three different implant systems during the first year of service. Int J Prosthodont 2002;15:259-266.
    • (2002) Int J Prosthodont , vol.15 , pp. 259-266
    • Watson, G.K.1    Payne, A.G.2    Purton, D.G.3    Thomson, W.M.4
  • 41
    • 67650860476 scopus 로고    scopus 로고
    • Rotational movements of mandibular two-implant overdentures
    • Kimoto S, Pan S, Drolet N, Feine JS. Rotational movements of mandibular two-implant overdentures. Clin Oral Implants Res 2009;20:838-843.
    • (2009) Clin Oral Implants Res , vol.20 , pp. 838-843
    • Kimoto, S.1    Pan, S.2    Drolet, N.3    Feine, J.S.4
  • 42
    • 0031086172 scopus 로고    scopus 로고
    • Comparison of retention and release periods for implant overdenture attachment
    • Petropoulos VC, Smith W, Kousvelari E. Comparison of retention and release periods for implant overdenture attachment. Int J Oral Maxillofac Implants 1997;12:176-185.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 176-185
    • Petropoulos, V.C.1    Smith, W.2    Kousvelari, E.3
  • 44
    • 0042921416 scopus 로고    scopus 로고
    • Posterior mandibular residual ridge resorption in patients with conventional dentures and implant overdentures
    • Kordatzis K, Wright PS, Meijer HJ. Posterior mandibular residual ridge resorption in patients with conventional dentures and implant overdentures. Int J Oral Maxillofac Implants 2003;18:447-452.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 447-452
    • Kordatzis, K.1    Wright, P.S.2    Meijer, H.J.3
  • 45
    • 0029204703 scopus 로고
    • Comparative study of antirotational single tooth abutments
    • Balfour A, O’Brien GR. Comparative study of antirotational single tooth abutments. J Prosthet Dent 1995;73:36-43.
    • (1995) J Prosthet Dent , vol.73 , pp. 36-43
    • Balfour, A.1    O’Brien, G.R.2
  • 46
    • 0031296495 scopus 로고    scopus 로고
    • Comparison of strength and failure mode of seven implant systems: An in vitro test
    • Mollersten L, Lockowandt P, Linden LA. Comparison of strength and failure mode of seven implant systems: An in vitro test. J Prosthet Dent 1997;78:582-591.
    • (1997) J Prosthet Dent , vol.78 , pp. 582-591
    • Mollersten, L.1    Lockowandt, P.2    Linden, L.A.3
  • 47
    • 17144365053 scopus 로고    scopus 로고
    • Long-term treatment costs associated with implant-supported mandibular prostheses in edentulous patients
    • Attard NJ, Zarb GA, Laporte A. Long-term treatment costs associated with implant-supported mandibular prostheses in edentulous patients. Int J Prosthodont 2005;18:117-123.
    • (2005) Int J Prosthodont , vol.18 , pp. 117-123
    • Attard, N.J.1    Zarb, G.A.2    Laporte, A.3
  • 48
    • 13444259470 scopus 로고    scopus 로고
    • An economic evaluation of implant treatment in edentulous patients-preliminary results
    • Zitzman NU, Sendi P, Marinello CP. An economic evaluation of implant treatment in edentulous patients-preliminary results. Int J Prosthodont 2005;18:20-27.
    • (2005) Int J Prosthodont , vol.18 , pp. 20-27
    • Zitzman, N.U.1    Sendi, P.2    Marinello, C.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.