메뉴 건너뛰기




Volumn 17, Issue 4, 2012, Pages 409-415

New approaches for detecting complement-fixing antibodies

Author keywords

Antibody mediated rejection; C1q assay; C4d assay; Complement; Desensitization

Indexed keywords

COMPLEMENT COMPONENT C1Q; COMPLEMENT COMPONENT C4D; COMPLEMENT FIXING ANTIBODY; EPITOPE; HLA ANTIGEN; IMMUNOGLOBULIN; IMMUNOGLOBULIN G; IMMUNOGLOBULIN M ANTIBODY; PANEL REACTIVE ANTIBODY;

EID: 84863847357     PISSN: 10872418     EISSN: 15317013     Source Type: Journal    
DOI: 10.1097/MOT.0b013e328355fb9b     Document Type: Review
Times cited : (25)

References (34)
  • 1
    • 79958803569 scopus 로고    scopus 로고
    • Antibody-mediated rejection-an ounce of prevention is worth a pound of cure
    • Bradley JA, Baldwin WM, Bingaman A, et al. Antibody-mediated rejection-an ounce of prevention is worth a pound of cure. Am J Transplant 2011; 11:1131-1139.
    • (2011) Am J Transplant , vol.11 , pp. 1131-1139
    • Bradley, J.A.1    Baldwin, W.M.2    Bingaman, A.3
  • 2
    • 77954235492 scopus 로고    scopus 로고
    • Recombinant human C1-inhibitor prevents acute antibody-mediated rejection in alloimmunized baboons
    • Tillou X, Poirier N, Le Bas-Bernardet S, et al. Recombinant human C1-inhibitor prevents acute antibody-mediated rejection in alloimmunized baboons. Kidney Int 2010; 78:152-159.
    • (2010) Kidney Int , vol.78 , pp. 152-159
    • Tillou, X.1    Poirier, N.2    Le Bas-Bernardet, S.3
  • 3
    • 79960316724 scopus 로고    scopus 로고
    • Systemic complement activation in deceased donors is associated with acute rejection after renal transplantation in the recipient
    • Damman J, Seelen MA, Moers C, et al. Systemic complement activation in deceased donors is associated with acute rejection after renal transplantation in the recipient. Transplantation 2011; 92:163-169.
    • (2011) Transplantation , vol.92 , pp. 163-169
    • Damman, J.1    Seelen, M.A.2    Moers, C.3
  • 4
    • 79954654804 scopus 로고    scopus 로고
    • No association of kidney graft loss with human leukocyte antigen antibodies detected exclusively by sensitive luminex single-antigen testing: A Collaborative Transplant Study Report
    • Susal C, Ovens J, Mahmoud K, et al. No association of kidney graft loss with human leukocyte antigen antibodies detected exclusively by sensitive luminex single-antigen testing: a Collaborative Transplant Study Report. Transplantation 2011; 91:883-887.
    • (2011) Transplantation , vol.91 , pp. 883-887
    • Susal, C.1    Ovens, J.2    Mahmoud, K.3
  • 5
    • 80054742066 scopus 로고    scopus 로고
    • Human leukocyte antigen antibodyincompatible renal transplantation: Excellent medium-term outcomes with negative cytotoxic crossmatch
    • Higgins R, Lowe D, Hathaway M, et al. Human leukocyte antigen antibodyincompatible renal transplantation: excellent medium-term outcomes with negative cytotoxic crossmatch. Transplantation 2011; 92:900-906.
    • (2011) Transplantation , vol.92 , pp. 900-906
    • Higgins, R.1    Lowe, D.2    Hathaway, M.3
  • 6
    • 80051779573 scopus 로고    scopus 로고
    • Pretransplant screening for donor-specific antibodies and graft loss
    • Focosi D, Boggi U. Pretransplant screening for donor-specific antibodies and graft loss. Transplantation 2011; 92:E15.
    • (2011) Transplantation , vol.92
    • Focosi, D.1    Boggi, U.2
  • 7
    • 80051778453 scopus 로고    scopus 로고
    • Pretransplant screening for donor-specific antibodies and graft loss reply
    • Susal C, Opelz G. Pretransplant screening for donor-specific antibodies and graft loss reply. Transplantation 2011; 92:E15-E16.
    • (2011) Transplantation , vol.92
    • Susal, C.1    Opelz, G.2
  • 8
    • 79952184151 scopus 로고    scopus 로고
    • Interpretation of positive flow cytometric crossmatch in the era of the single-antigen bead assay
    • Couzi L, Araujo C, Guidicelli G, et al. Interpretation of positive flow cytometric crossmatch in the era of the single-antigen bead assay. Transplantation 2011; 91:527-535.
    • (2011) Transplantation , vol.91 , pp. 527-535
    • Couzi, L.1    Araujo, C.2    Guidicelli, G.3
  • 9
    • 0014662180 scopus 로고
    • Significance of positive crossmatch test in kidney transplantation
    • Patel R, Terasaki PI. Significance of positive crossmatch test in kidney transplantation. New Engl J Med 1969; 280:735-739.
    • (1969) New Engl J Med , vol.280 , pp. 735-739
    • Patel, R.1    Terasaki, P.I.2
  • 10
    • 0344405754 scopus 로고    scopus 로고
    • Flow cytometry based detection of HLA alloantibody mediated classical complement activation
    • Wahrmann M, Exner M, Regele H, et al. Flow cytometry based detection of HLA alloantibody mediated classical complement activation. J Immunol Methods 2003; 275:149-160.
    • (2003) J Immunol Methods , vol.275 , pp. 149-160
    • Wahrmann, M.1    Exner, M.2    Regele, H.3
  • 11
    • 35748973229 scopus 로고    scopus 로고
    • C4d fixing, luminex binding antibodies: A new tool for prediction of graft failure after heart transplantation
    • Smith JD, Hamour IM, Banner NR, Rose ML. C4d fixing, luminex binding antibodies: a new tool for prediction of graft failure after heart transplantation. Am J Transplant 2007; 7:2809-2815.
    • (2007) Am J Transplant , vol.7 , pp. 2809-2815
    • Smith, J.D.1    Hamour, I.M.2    Banner, N.R.3    Rose, M.L.4
  • 12
    • 77954230424 scopus 로고    scopus 로고
    • A complementary approach to treating antibody-mediated transplant rejection
    • Heeger PS. A complementary approach to treating antibody-mediated transplant rejection. Kidney Int 2010; 78:125-127.
    • (2010) Kidney Int , vol.78 , pp. 125-127
    • Heeger, P.S.1
  • 13
    • 80052963404 scopus 로고    scopus 로고
    • Novel C1q assay reveals a clinically relevant subset of human leukocyte antigen antibodies independent of immunoglobulin G strength on single antigen beads
    • Chen G, Sequeira F, Tyan DB. Novel C1q assay reveals a clinically relevant subset of human leukocyte antigen antibodies independent of immunoglobulin G strength on single antigen beads. Hum Immunol 2011; 72:849-858.
    • (2011) Hum Immunol , vol.72 , pp. 849-858
    • Chen, G.1    Sequeira, F.2    Tyan, D.B.3
  • 14
    • 84863843678 scopus 로고    scopus 로고
    • Parallel C1q and IgG assays on single antigen beads reveal that the presence of IgM complement fixing antibodies can obscure clinically relevant IgG antibodies to the same allele
    • Chen G, Sequeira F, Tyan D. Parallel C1q and IgG assays on single antigen beads reveal that the presence of IgM complement fixing antibodies can obscure clinically relevant IgG antibodies to the same allele. Hum Immunol 2011; 72:S12.
    • (2011) Hum Immunol , vol.72
    • Chen, G.1    Sequeira, F.2    Tyan, D.3
  • 15
    • 84863851318 scopus 로고    scopus 로고
    • Detection of C1q-fixing antibodies correlates with AHG-complement dependent cytotoxicity crossmatch results
    • Rhodes CL, Mata N, Abes P, Rao P. Detection of C1q-fixing antibodies correlates with AHG-complement dependent cytotoxicity crossmatch results. Hum Immunol 2011; 72:S58.
    • (2011) Hum Immunol , vol.72
    • Rhodes, C.L.1    Mata, N.2    Abes, P.3    Rao, P.4
  • 16
    • 84876450235 scopus 로고    scopus 로고
    • C1q binding donor specific HLA antibody monitoring by Luminex single antigen assay is useful in predicting clinical events
    • Lunz JG, Webber S, Soltys K, et al. C1q binding donor specific HLA antibody monitoring by Luminex single antigen assay is useful in predicting clinical events. Hum Immunol 2011; 72:S50.
    • (2011) Hum Immunol , vol.72
    • Lunz, J.G.1    Webber, S.2    Soltys, K.3
  • 17
    • 84863839187 scopus 로고    scopus 로고
    • Luminex-C1q: A reliable virtual crossmatch (VXM) to predict final CDC crossmatch
    • Chen G, Sequeira F, Tyan D. Luminex-C1q: a reliable virtual crossmatch (VXM) to predict final CDC crossmatch. Hum Immunol 2011; 72:S14.
    • (2011) Hum Immunol , vol.72
    • Chen, G.1    Sequeira, F.2    Tyan, D.3
  • 18
    • 84876441638 scopus 로고    scopus 로고
    • HLA antibodies that are not detected by the C1q screen (can fix complement and are clinically significant
    • Fuller A, Williams K, Hurst D, et al. HLA antibodies that are not detected by the C1q screen (can fix complement and are clinically significant. Hum Immunol 2011; 72:S30.
    • (2011) Hum Immunol , vol.72
    • Fuller, A.1    Williams, K.2    Hurst, D.3
  • 19
    • 84863851766 scopus 로고    scopus 로고
    • Which Is the clinically relevant antibody in patients waiting for transplantation: Luminex SAB screens versus C1q assays?
    • Phelan DL, Harrell K, Clark D, Mohanakumar T. Which Is the clinically relevant antibody in patients waiting for transplantation: Luminex SAB screens versus C1q assays? Hum Immunol 2011; 72:S54.
    • (2011) Hum Immunol , vol.72
    • Phelan, D.L.1    Harrell, K.2    Clark, D.3    Mohanakumar, T.4
  • 20
    • 84861816090 scopus 로고    scopus 로고
    • Pretransplant donor-specific HLA class-I and -II antibodies are associated with an increased risk for kidney graft failure
    • Otten HG, Verhaar MC, Borst HP, et al. Pretransplant donor-specific HLA class-I and -II antibodies are associated with an increased risk for kidney graft failure. Am J Transplant. 2012; 12:1618-1623.
    • (2012) Am J Transplant. , vol.12 , pp. 1618-1623
    • Otten, H.G.1    Verhaar, M.C.2    Borst, H.P.3
  • 21
    • 84863851316 scopus 로고    scopus 로고
    • Association of C4d staining, single antigen antibody analysis and the C1q binding assay
    • Kukuruga D, Drachenberg C, Haririan A. Association of C4d staining, single antigen antibody analysis and the C1q binding assay. Hum Immunol 2011; 72:S13.
    • (2011) Hum Immunol , vol.72
    • Kukuruga, D.1    Drachenberg, C.2    Haririan, A.3
  • 22
    • 80052414139 scopus 로고    scopus 로고
    • HLA antibody specification using single-antigen beads: A technical solution for the prozone effect
    • Schnaidt M, Weinstock C, Jurisic M, et al. HLA antibody specification using single-antigen beads: a technical solution for the prozone effect. Transplantation 2011; 92:510-515.
    • (2011) Transplantation , vol.92 , pp. 510-515
    • Schnaidt, M.1    Weinstock, C.2    Jurisic, M.3
  • 23
    • 84876450731 scopus 로고    scopus 로고
    • C1q-fixing antibodies in highly sensitised patients waiting for a small bowel transplant without the liver
    • X11 International Small Bowel Transplant Symposium, Washington DC, Abstract Book. [Accessed on 15-18 November 2011]
    • Page S, Fuggle S, Vaidya A, Friend P. C1q-fixing antibodies in highly sensitised patients waiting for a small bowel transplant without the liver. The Oxford experience. X11 International Small Bowel Transplant Symposium, Washington DC, Abstract Book www.isbts2011.org. [Accessed on 15-18 November 2011].
    • The Oxford Experience
    • Page, S.1    Fuggle, S.2    Vaidya, A.3    Friend, P.4
  • 24
    • 79959681115 scopus 로고    scopus 로고
    • Pretransplant IgG subclasses of donorspecific human leukocyte antigen antibodies and development of antibodymediated rejection
    • Honger G, Hopfer H, Arnold ML, et al. Pretransplant IgG subclasses of donorspecific human leukocyte antigen antibodies and development of antibodymediated rejection. Transplantation 2011; 92:41-47.
    • (2011) Transplantation , vol.92 , pp. 41-47
    • Honger, G.1    Hopfer, H.2    Arnold, M.L.3
  • 25
    • 33745228786 scopus 로고    scopus 로고
    • Pivotal role of complement-fixing HLA alloantibodies in presensitized kidney allograft recipients
    • Wahrmann M, Exner M, Schillinger M, et al. Pivotal role of complement-fixing HLA alloantibodies in presensitized kidney allograft recipients. Am J Transplant 2006; 6 (5 Pt 1):1033-1041.
    • (2006) Am J Transplant , vol.6 , Issue.5 PART. 1 , pp. 1033-1041
    • Wahrmann, M.1    Exner, M.2    Schillinger, M.3
  • 26
    • 37549043577 scopus 로고    scopus 로고
    • In vitro detection of C4d-fixing HLA alloantibodies: Associations with capillary C4d deposition in kidney allografts
    • Bartel G, Wahrmann M, Exner M, et al. In vitro detection of C4d-fixing HLA alloantibodies: Associations with capillary C4d deposition in kidney allografts. Am J Transplant 2008; 8:41-49.
    • (2008) Am J Transplant , vol.8 , pp. 41-49
    • Bartel, G.1    Wahrmann, M.2    Exner, M.3
  • 27
    • 77954089708 scopus 로고    scopus 로고
    • C4d-fixing capability of low-level donor-specific HLA antibodies is not predictive for early antibody-mediated rejection
    • Honger G, Wahrmann M, Amico P, et al. C4d-fixing capability of low-level donor-specific HLA antibodies is not predictive for early antibody-mediated rejection. Transplantation 2010; 89:1471-1475.
    • (2010) Transplantation , vol.89 , pp. 1471-1475
    • Honger, G.1    Wahrmann, M.2    Amico, P.3
  • 28
    • 78650490065 scopus 로고    scopus 로고
    • C4d binding correlated with strong HLA antibodies involved in graft failures
    • Mizutani K, Gotoh M. C4d binding correlated with strong HLA antibodies involved in graft failures. Transplant Proc 2010; 42:4021-4025.
    • (2010) Transplant Proc , vol.42 , pp. 4021-4025
    • Mizutani, K.1    Gotoh, M.2
  • 29
    • 79551472638 scopus 로고    scopus 로고
    • De novo donor HLA-specific antibodies after heart transplantation are an independent predictor of poor patient survival
    • Smith JD, Banner NR, Hamour IM, et al. De novo donor HLA-specific antibodies after heart transplantation are an independent predictor of poor patient survival. Am J Transplant 2011; 11:312-319.
    • (2011) Am J Transplant , vol.11 , pp. 312-319
    • Smith, J.D.1    Banner, N.R.2    Hamour, I.M.3
  • 30
    • 79951517540 scopus 로고    scopus 로고
    • C1q-fixing human leukocyte antigen antibodies are specific for predicting transplant glomerulopathy and late graft failure after kidney transplantation
    • Yabu JM, Higgins JP, Chen G, et al. C1q-fixing human leukocyte antigen antibodies are specific for predicting transplant glomerulopathy and late graft failure after kidney transplantation. Transplantation 2011; 91:342-347.
    • (2011) Transplantation , vol.91 , pp. 342-347
    • Yabu, J.M.1    Higgins, J.P.2    Chen, G.3
  • 31
    • 84855992990 scopus 로고    scopus 로고
    • Complement-fixing donorspecific antibodies identified by a novel C1q assay are associated with allograft loss
    • Sutherland SM, Chen G, Sequeira FA, et al. Complement-fixing donorspecific antibodies identified by a novel C1q assay are associated with allograft loss. Pediatr Transplant 2012; 16:12-17.
    • (2012) Pediatr Transplant , vol.16 , pp. 12-17
    • Sutherland, S.M.1    Chen, G.2    Sequeira, F.A.3
  • 32
    • 78650960273 scopus 로고    scopus 로고
    • Clinical usefulness of a novel C1q assay to detect immunoglobulinGantibodies capable of fixing complement in sensitized pediatric heart transplant patients
    • Chin C, Chen G, Sequeria F, et al. Clinical usefulness of a novel C1q assay to detect immunoglobulinGantibodies capable of fixing complement in sensitized pediatric heart transplant patients. JHeart Lung Transplant2011; 30: 158-163.
    • (2011) JHeart Lung Transplant , vol.30 , pp. 158-163
    • Chin, C.1    Chen, G.2    Sequeria, F.3
  • 33
    • 84355166410 scopus 로고    scopus 로고
    • Human leukocyte antigen epitope analysis to assess complement-and noncomplement-binding donor-specific antibody repertoire in a pediatric heart transplant recipient
    • Zeevi A, Marrari M, Feingold B, et al. Human leukocyte antigen epitope analysis to assess complement-and noncomplement-binding donor-specific antibody repertoire in a pediatric heart transplant recipient. Hum Immunol 2012; 73:48-51.
    • (2012) Hum Immunol , vol.73 , pp. 48-51
    • Zeevi, A.1    Marrari, M.2    Feingold, B.3
  • 34
    • 84876444620 scopus 로고    scopus 로고
    • Successful avoidance of posttransplant antibody mediated rejection when desensitizing patients with IVIG: In vitro C1q test predicts and monitors in vivo efficacy and time to transplant
    • Tyan D, Yabu J, Chen G, et al. Successful avoidance of posttransplant antibody mediated rejection when desensitizing patients with IVIG: in vitro C1q test predicts and monitors in vivo efficacy and time to transplant. Am J Transplant 2011; 11 (S2):91.
    • (2011) Am J Transplant , vol.11 , Issue.S2 , pp. 91
    • Tyan, D.1    Yabu, J.2    Chen, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.