메뉴 건너뛰기




Volumn 7, Issue 7, 2012, Pages

Room temperature operable autonomously moving bio-microrobot powered by insect dorsal vessel tissue

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL TISSUE; ARTICLE; DORSAL VESSEL TISSUE; FORCE; INCHWORM; MECHANICAL STIMULATION; MICROTECHNOLOGY; MUSCLE CONTRACTION; NONHUMAN; POLYPOD MICROROBOT; ROBOTICS; ROOM TEMPERATURE; VASCULAR TISSUE; VELOCITY; WORM;

EID: 84863812081     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0038274     Document Type: Article
Times cited : (65)

References (28)
  • 2
    • 36248974668 scopus 로고    scopus 로고
    • Mobile robots: motor challenges and materials solutions
    • Madden JD, (2007) Mobile robots: motor challenges and materials solutions. Science 318: 1094-1097.
    • (2007) Science , vol.318 , pp. 1094-1097
    • Madden, J.D.1
  • 4
    • 33748501236 scopus 로고    scopus 로고
    • Demonstration of a bio-microactuator powered by cultured cardiomyocytes coupled to hydrogel micropillars
    • Morishima K, Tanaka Y, Ebara M, Shimizu T, Kikuchi A, et al. (2006) Demonstration of a bio-microactuator powered by cultured cardiomyocytes coupled to hydrogel micropillars. Sens Act B 119: 345-350.
    • (2006) Sens Act B , vol.119 , pp. 345-350
    • Morishima, K.1    Tanaka, Y.2    Ebara, M.3    Shimizu, T.4    Kikuchi, A.5
  • 5
    • 33645501932 scopus 로고    scopus 로고
    • Demonstration of a PDMS-based bio-microactuator using cultured cardiomyocytes to drive polymer micropillars
    • Tanaka Y, Morishima K, Shimizu T, Kikuchi A, Yamato M, et al. (2006) Demonstration of a PDMS-based bio-microactuator using cultured cardiomyocytes to drive polymer micropillars. Lab Chip 6: 230-235.
    • (2006) Lab Chip , vol.6 , pp. 230-235
    • Tanaka, Y.1    Morishima, K.2    Shimizu, T.3    Kikuchi, A.4    Yamato, M.5
  • 6
    • 33644640310 scopus 로고    scopus 로고
    • An actuated pump on-chip powered by cultured cardiomyocytes
    • Tanaka Y, Morishima K, Shimizu T, Kikuchi A, Yamato M, et al. (2006) An actuated pump on-chip powered by cultured cardiomyocytes. Lab Chip 6: 362-368.
    • (2006) Lab Chip , vol.6 , pp. 362-368
    • Tanaka, Y.1    Morishima, K.2    Shimizu, T.3    Kikuchi, A.4    Yamato, M.5
  • 7
    • 33846922537 scopus 로고    scopus 로고
    • A micro-spherical heart pump powered by cultured cardiomyocytes
    • Tanaka Y, Sato K, Shimizu T, Yamato M, Okano T, et al. (2007) A micro-spherical heart pump powered by cultured cardiomyocytes. Lab Chip 7: 207-212.
    • (2007) Lab Chip , vol.7 , pp. 207-212
    • Tanaka, Y.1    Sato, K.2    Shimizu, T.3    Yamato, M.4    Okano, T.5
  • 8
    • 13144295042 scopus 로고    scopus 로고
    • Self-assembled microdevices driven by muscle
    • Xi J, Schmidt JJ, Montemagno CD, (2005) Self-assembled microdevices driven by muscle. Nat Mater 4: 180-184.
    • (2005) Nat Mater , vol.4 , pp. 180-184
    • Xi, J.1    Schmidt, J.J.2    Montemagno, C.D.3
  • 10
    • 33748180652 scopus 로고    scopus 로고
    • Fabrication of patterned micromuscles with high activity for powering biohybrid microdevices
    • Kim DH, Park JY, Suh KY, Kim P, Choi SK, et al. (2006) Fabrication of patterned micromuscles with high activity for powering biohybrid microdevices. Sens. Actuators B 117: 391-400.
    • (2006) Sens. Actuators B , vol.117 , pp. 391-400
    • Kim, D.H.1    Park, J.Y.2    Suh, K.Y.3    Kim, P.4    Choi, S.K.5
  • 11
    • 35549013238 scopus 로고    scopus 로고
    • Establishment of a fabrication method for a long-term actuated hybrid cell robot
    • Kim J, Park J, Yang S, Baek J, Kim B, et al. (2007) Establishment of a fabrication method for a long-term actuated hybrid cell robot. Lab Chip 7: 1504-1508.
    • (2007) Lab Chip , vol.7 , pp. 1504-1508
    • Kim, J.1    Park, J.2    Yang, S.3    Baek, J.4    Kim, B.5
  • 12
    • 34748846254 scopus 로고    scopus 로고
    • Micro pumping with cardiomyocyte-polymer hybrid
    • Park J, Kim IC, Baek J, Cha M, Kim J, et al. (2007) Micro pumping with cardiomyocyte-polymer hybrid. Lab Chip 7: 1367-1370.
    • (2007) Lab Chip , vol.7 , pp. 1367-1370
    • Park, J.1    Kim, I.C.2    Baek, J.3    Cha, M.4    Kim, J.5
  • 15
    • 76949090414 scopus 로고    scopus 로고
    • Fabrication and evaluation of reconstructed cardiac tissue and its application to bio-actuated microdevices
    • Horiguchi H, Imagawa K, Hoshino T, Akiyama Y, Morishima K, (2009) Fabrication and evaluation of reconstructed cardiac tissue and its application to bio-actuated microdevices. IEEE Trans Nano Bioscience 8: 349-355.
    • (2009) IEEE Trans Nano Bioscience , vol.8 , pp. 349-355
    • Horiguchi, H.1    Imagawa, K.2    Hoshino, T.3    Akiyama, Y.4    Morishima, K.5
  • 16
    • 78650313442 scopus 로고    scopus 로고
    • Rod-shaped tissue engineered skeletal muscle with artificial anchors to utilize as a bio-actuator
    • Akiyama Y, Terada R, Hashimoto M, Hoshino T, Furukawa Y, et al. (2010) Rod-shaped tissue engineered skeletal muscle with artificial anchors to utilize as a bio-actuator. J Biomed Sci Eng 5: 236-244.
    • (2010) J Biomed Sci Eng , vol.5 , pp. 236-244
    • Akiyama, Y.1    Terada, R.2    Hashimoto, M.3    Hoshino, T.4    Furukawa, Y.5
  • 17
    • 67650667450 scopus 로고    scopus 로고
    • Control of myotube contraction using electrical pulse stimulation for bio-actuator
    • Yamasaki K, Hayashi H, Nishiyama K, Kobayashi H, Uto S, et al. (2009) Control of myotube contraction using electrical pulse stimulation for bio-actuator. J Artif Organs 12: 131-137.
    • (2009) J Artif Organs , vol.12 , pp. 131-137
    • Yamasaki, K.1    Hayashi, H.2    Nishiyama, K.3    Kobayashi, H.4    Uto, S.5
  • 18
    • 78650313442 scopus 로고    scopus 로고
    • Rod-shaped tissue engineered skeletal muscle with artificial anchors to utilize as a bio-actuator
    • Akiyama Y, Terada R, Hashimoto H, Hoshino T, Furukawa, et al. (2010) Rod-shaped tissue engineered skeletal muscle with artificial anchors to utilize as a bio-actuator. J Biomech Sci Eng 5: 236-244.
    • (2010) J Biomech Sci Eng , vol.5 , pp. 236-244
    • Akiyama, Y.1    Terada, R.2    Hashimoto, H.3    Hoshino, T.4    Furukawa5
  • 19
    • 37249063857 scopus 로고    scopus 로고
    • Culture of insect cells contracting spontaneously; research moving toward an environmentally robust hybrid robotic system
    • Akiyama Y, Iwabuchi K, Furukawa Y, Morishima K, (2008) Culture of insect cells contracting spontaneously; research moving toward an environmentally robust hybrid robotic system. J Biotechnol 133: 261-266.
    • (2008) J Biotechnol , vol.133 , pp. 261-266
    • Akiyama, Y.1    Iwabuchi, K.2    Furukawa, Y.3    Morishima, K.4
  • 20
    • 57449092082 scopus 로고    scopus 로고
    • Long-term and room temperature operable bioactuator powered by insect dorsal vessel tissue
    • Akiyama Y, Iwabuchi K, Furukawa Y, Morishima K, (2009) Long-term and room temperature operable bioactuator powered by insect dorsal vessel tissue. Lab Chip 9: 140-144.
    • (2009) Lab Chip , vol.9 , pp. 140-144
    • Akiyama, Y.1    Iwabuchi, K.2    Furukawa, Y.3    Morishima, K.4
  • 22
    • 77952098295 scopus 로고    scopus 로고
    • Electrical stimulation of cultured lepidopteran dorsal vessel tissue: an experiment for development of bioactuators
    • Akiyama Y, Iwabuchi K, Furukawa Y, Morishima K, (2010) Electrical stimulation of cultured lepidopteran dorsal vessel tissue: an experiment for development of bioactuators. In Vitro Cell Dev Biol-Animal 46: 411-415.
    • (2010) In Vitro Cell Dev Biol-Animal , vol.46 , pp. 411-415
    • Akiyama, Y.1    Iwabuchi, K.2    Furukawa, Y.3    Morishima, K.4
  • 25
    • 0037452695 scopus 로고    scopus 로고
    • Cells lying on a bed of microneedles: An approach to isolate mechanical force
    • Tan JL, Tien J, Pirone DM, Gray DS, Bhadriraju K, et al. (2003) Cells lying on a bed of microneedles: An approach to isolate mechanical force. Proc Natl Acad Sci U S A 100: 1484-1489.
    • (2003) Proc Natl Acad Sci U S A , vol.100 , pp. 1484-1489
    • Tan, J.L.1    Tien, J.2    Pirone, D.M.3    Gray, D.S.4    Bhadriraju, K.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.