-
1
-
-
0026804696
-
Water-equivalent plastic scintillation detectors for High-energy beam dosimetry: I. Physical characteristics and theoretical consideration
-
A. S. Beddar, T. R. Mackie, and F. H. Attix, "Water-equivalent plastic scintillation detectors for High-energy beam dosimetry: I. Physical characteristics and theoretical consideration," Phys. Med. Biol. 37(10), 1883-1900 (1992).
-
(1992)
Phys. Med. Biol.
, vol.37
, Issue.10
, pp. 1883-1900
-
-
Beddar, A.S.1
Mackie, T.R.2
Attix, F.H.3
-
2
-
-
34247629705
-
Water-equivalent dosimeter array for small-field external beam radiotherapy
-
L. Archambault, A. S. Beddar, L. Gingras, F. Lacroix, R. Roy, and L. Beaulieu, "Water-equivalent dosimeter array for small-field external beam radiotherapy," Med. Phys. 34(5), 1583-1592 (2007).
-
(2007)
Med. Phys.
, vol.34
, Issue.5
, pp. 1583-1592
-
-
Archambault, L.1
Beddar, A.S.2
Gingras, L.3
Lacroix, F.4
Roy, R.5
Beaulieu, L.6
-
3
-
-
78650802373
-
SSPM based radiation sensing: Preliminary laboratory and clinical results
-
D. C. Konnoff, T. K. Plant, and E. Shiner, "SSPM based radiation sensing: Preliminary laboratory and clinical results," Radiat. Meas. 46(1), 76-87 (2011).
-
(2011)
Radiat. Meas.
, vol.46
, Issue.1
, pp. 76-87
-
-
Konnoff, D.C.1
Plant, T.K.2
Shiner, E.3
-
4
-
-
0033871604
-
X-ray imaging and detection using plastic scintillating fibers
-
A. Ikhlef, M. Skowronek, and A. S. Beddar, "X-ray imaging and detection using plastic scintillating fibers," Nucl. Instrum. Methods Phys. Res. A 442(1-3), 428-432 (2000).
-
(2000)
Nucl. Instrum. Methods Phys. Res. A
, vol.442
, Issue.1-3
, pp. 428-432
-
-
Ikhlef, A.1
Skowronek, M.2
Beddar, A.S.3
-
5
-
-
4244140823
-
The light yield response of NE213 organic scintillators to charged particles resulting from neutron interactions
-
S. Mouatassim, G. J. Costa, G. Guillaume, B. Heusch, A. Huck, and M. Moszynski, "The light yield response of NE213 organic scintillators to charged particles resulting from neutron interactions," Nucl. Instrum. Methods Phys. Res. A 359(3), 530-536 (1995).
-
(1995)
Nucl. Instrum. Methods Phys. Res. A
, vol.359
, Issue.3
, pp. 530-536
-
-
Mouatassim, S.1
Costa, G.J.2
Guillaume, G.3
Heusch, B.4
Huck, A.5
Moszynski, M.6
-
6
-
-
0002512920
-
The response of plastic scintillator to protons and deuterons
-
G. V. O'Rielly, N. R. Kolb, and R. E. Pywell, "The response of plastic scintillator to protons and deuterons," Nucl. Instrum. Methods Phys. Res. A 368(3), 745-749 (1996).
-
(1996)
Nucl. Instrum. Methods Phys. Res. A
, vol.368
, Issue.3
, pp. 745-749
-
-
O'Rielly, G.V.1
Kolb, N.R.2
Pywell, R.E.3
-
7
-
-
0034300792
-
Plastic scintillator investigations for relative dosimetry in proton-Therapy
-
L. Torrisi, "Plastic scintillator investigations for relative dosimetry in proton-Therapy," Nucl. Instrum. Methods Phys. Res. B 170(3-4), 523-530 (2000).
-
(2000)
Nucl. Instrum. Methods Phys. Res. B
, vol.170
, Issue.3-4
, pp. 523-530
-
-
Torrisi, L.1
-
8
-
-
37849023051
-
Real-Time fiber optic radiation dosimeters for nuclear environment monitoring around thermonuclear reactors
-
A. F. Fernandez, B. Brichard, S. O'Keeffe, C. Fitzpatrick, E. Lewis, J.-R. Vaille, L. Dusseau, D. A. Jackson, F. Ravotti, M. Glaser, and H. El-Rabii, "Real-Time fiber optic radiation dosimeters for nuclear environment monitoring around thermonuclear reactors," Fusion Eng. Des. 83(1), 50-59 (2008).
-
(2008)
Fusion Eng. Des.
, vol.83
, Issue.1
, pp. 50-59
-
-
Fernandez, A.F.1
Brichard, B.2
O'Keeffe, S.3
Fitzpatrick, C.4
Lewis, E.5
Vaille, J.-R.6
Dusseau, L.7
Jackson, D.A.8
Ravotti, F.9
Glaser, M.10
El-Rabii, H.11
-
9
-
-
41149109691
-
A review of optical fibre radiation dosimeters
-
S. O'Keeffe, C. Fitzpatrick, E. Lewis, and A. I. Al-Shamma'a, "A review of optical fibre radiation dosimeters," Sensor Rev. 28(2), 136-142 (2008).
-
(2008)
Sensor Rev.
, vol.28
, Issue.2
, pp. 136-142
-
-
O'Keeffe, S.1
Fitzpatrick, C.2
Lewis, E.3
Al-Shamma'a, A.I.4
-
10
-
-
0034270528
-
Polymer-polymer miscibility study for plastic gradient index optical fiber
-
B. Lee, W. Y. Choi, and J. K. Walker, "Polymer-polymer miscibility study for plastic gradient index optical fiber," Polym. Eng. Sci. 40(9), 1996-1999 (2000).
-
(2000)
Polym. Eng. Sci.
, vol.40
, Issue.9
, pp. 1996-1999
-
-
Lee, B.1
Choi, W.Y.2
Walker, J.K.3
-
11
-
-
33846936228
-
A real time scintillating fiberdosimeter for gamma and neutron monitoring on radiotherapy accelerators
-
G. Bartesaghi, V. Conti, M. Prest, V. Mascagna, S. Scazzi, P. Cappelletti, M. Frigerio, S. Gelosa, A. Monti, A. Ostinelli, A. Mozzanica, R. Bevilacqua, G. Giannini, P. Totaro, and E. Vallazza, "A real time scintillating fiberdosimeter for gamma and neutron monitoring on radiotherapy accelerators," Nucl. Instrum. Methods Phys. Res. A 572(1), 228-230 (2007).
-
(2007)
Nucl. Instrum. Methods Phys. Res. A
, vol.572
, Issue.1
, pp. 228-230
-
-
Bartesaghi, G.1
Conti, V.2
Prest, M.3
Mascagna, V.4
Scazzi, S.5
Cappelletti, P.6
Frigerio, M.7
Gelosa, S.8
Monti, A.9
Ostinelli, A.10
Mozzanica, A.11
Bevilacqua, R.12
Giannini, G.13
Totaro, P.14
Vallazza, E.15
-
12
-
-
85008020251
-
Characterization of one-dimensional fiber-optic scintillating detectors for electron-beam therapy dosimetry
-
B. Lee, K. W. Jang, D. H. Cho, W. J. Yoo, S. H. Shin, G.-R. Tack, S.-C. Chung, S. Kim, H. Cho, B. G. Park, J. H. Moon, and S. Kim, " Characterization of one-dimensional fiber-optic scintillating detectors for electron-beam therapy dosimetry," IEEE Trans. Nucl. Sci. 55(5), 2627-2631 (2008).
-
(2008)
IEEE Trans. Nucl. Sci.
, vol.55
, Issue.5
, pp. 2627-2631
-
-
Lee, B.1
Jang, K.W.2
Cho, D.H.3
Yoo, W.J.4
Shin, S.H.5
Tack, G.-R.6
Chung, S.-C.7
Kim, S.8
Cho, H.9
Park, B.G.10
Moon, J.H.11
Kim, S.12
-
13
-
-
85008040113
-
Measurement of two-dimensional photon beam distributions using a fiber-optic radiation sensor for small field radiation therapy
-
B. Lee, K. W. Jang, D. H. Cho, W. J. Yoo, S. H. Shin, H. S. Kim, J. H. Yi, S. Kim, H. Cho, B. G. Park, J. H. Moon, and S. Kim, "Measurement of two-dimensional photon beam distributions using a fiber-optic radiation sensor for small field radiation therapy," IEEE Trans. Nucl. Sci. 55(5), 2632-2636 (2008).
-
(2008)
IEEE Trans. Nucl. Sci.
, vol.55
, Issue.5
, pp. 2632-2636
-
-
Lee, B.1
Jang, K.W.2
Cho, D.H.3
Yoo, W.J.4
Shin, S.H.5
Kim, H.S.6
Yi, J.H.7
Kim, S.8
Cho, H.9
Park, B.G.10
Moon, J.H.11
Kim, S.12
-
14
-
-
39749149036
-
Transmission of Cerenkov radiation in optical fibers
-
S. H. Law, N. Suchowerska, D. R. McKenzie, S. C. Fleming, and T. Lin, "Transmission of Cerenkov radiation in optical fibers," Opt. Lett. 32(10), 1205-1207 (2007).
-
(2007)
Opt. Lett.
, vol.32
, Issue.10
, pp. 1205-1207
-
-
Law, S.H.1
Suchowerska, N.2
McKenzie, D.R.3
Fleming, S.C.4
Lin, T.5
-
15
-
-
34547895500
-
Measurements and characterizations of Cerenkov light in fiber-optic radiation sensor irradiated by high energy electron beam
-
B. Lee, D. H. Cho, K. W. Jang, S. C. Chung, J. W. Lee, S. Kim, and H. Cho, "Measurements and characterizations of Cerenkov light in fiber-optic radiation sensor irradiated by high energy electron beam," Jpn. J. Appl. Phys. 45(10A), 7980-7982 (2006).
-
(2006)
Jpn. J. Appl. Phys.
, vol.45
, Issue.10 A
, pp. 7980-7982
-
-
Lee, B.1
Cho, D.H.2
Jang, K.W.3
Chung, S.C.4
Lee, J.W.5
Kim, S.6
Cho, H.7
-
16
-
-
34547678561
-
Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry
-
B. Lee, K. W. Jang, D. H. Cho, W. J. Yoo, G. R. Tack, S.-C. Chung, S. Kim, and H. Cho, "Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry," Nucl. Instrum. Methods Phys. Res. A 579(1), 344-348 (2007).
-
(2007)
Nucl. Instrum. Methods Phys. Res. A
, vol.579
, Issue.1
, pp. 344-348
-
-
Lee, B.1
Jang, K.W.2
Cho, D.H.3
Yoo, W.J.4
Tack, G.R.5
Chung, S.-C.6
Kim, S.7
Cho, H.8
-
17
-
-
79953670862
-
Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: A comparison study of calibration procedures and validation in Cerenkov light-dominated situations
-
M. Guillot, L. Gingras, L. Archambault, S. Beddar, and L. Beaulieu, "Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: A comparison study of calibration procedures and validation in Cerenkov light-dominated situations," Med. Phys. 38(4), 2140-2150 (2011).
-
(2011)
Med. Phys.
, vol.38
, Issue.4
, pp. 2140-2150
-
-
Guillot, M.1
Gingras, L.2
Archambault, L.3
Beddar, S.4
Beaulieu, L.5
-
19
-
-
0035355339
-
A miniature 'scintillator-fiberoptic-PMT' detector system for the dosimetry of small fields in stereotactic radiosurgery
-
A. S. Beddar, T. J. Kinsella, A. Ikhlef, and C. H. Sibata, "A miniature 'scintillator-fiberoptic-PMT' detector system for the dosimetry of small fields in stereotactic radiosurgery," IEEE Trans. Nucl. Sci. 48(3), 924-928 (2001).
-
(2001)
IEEE Trans. Nucl. Sci.
, vol.48
, Issue.3
, pp. 924-928
-
-
Beddar, A.S.1
Kinsella, T.J.2
Ikhlef, A.3
Sibata, C.H.4
-
20
-
-
34248504862
-
Plastic scintillation dosimetry and its application to radiotherapy
-
A. S. Beddar, "Plastic scintillation dosimetry and its application to radiotherapy," Radiat. Meas. 41, S124-S133 (2006).
-
(2006)
Radiat. Meas.
, vol.41
-
-
Beddar, A.S.1
-
21
-
-
33845624571
-
Polyvinyltoluene scintillators for relative ion dosimetry: An investigation with helium, carbon and neon beams
-
D. Broggio, R. Barillon, J.-M. Jung, N. Yasuda, T. Yamauchi, H. Kitamura, and P. Bischoff, "Polyvinyltoluene scintillators for relative ion dosimetry: An investigation with helium, carbon and neon beams," Nucl. Instrum. Methods Phys. Res. B 254(1), 3-9 (2007).
-
(2007)
Nucl. Instrum. Methods Phys. Res. B
, vol.254
, Issue.1
, pp. 3-9
-
-
Broggio, D.1
Barillon, R.2
Jung, J.-M.3
Yasuda, N.4
Yamauchi, T.5
Kitamura, H.6
Bischoff, P.7
|