메뉴 건너뛰기




Volumn 59, Issue 7, 2012, Pages 1487-1499

Implementation of a versatile research data acquisition system using a commercially available medical ultrasound scanner

Author keywords

[No Author keywords available]

Indexed keywords

AORTIC ANEURYSMS; BEAM ANGLE; BEAMFORMATION; BLOOD VELOCITY ESTIMATION; CAMERA LINKS; CLINICAL TRIAL; COLOR FLOW IMAGING; CONTROL PARAMETERS; CUSTOMIZED SOLUTIONS; DOPPLER; FLEXIBLE MANIPULATIONS; FOCAL DEPTH; FULL CONTROL; HIGH QUALITY IMAGES; IDENTICAL IMAGES; IMAGE PLANE; IMAGING DEVICE; IMAGING PARAMETERS; MEDICAL ULTRASOUND SCANNERS; MULTIPLE DATA TYPES; OPEN ARCHITECTURE; REFERENCE DATA; REGION OF INTEREST; REGIONS OF INTEREST; RESEARCH DATA; RF DATA; SOFTWARE DEVELOPMENT TOOLKIT; SYSTEM USE; TRANSVERSE OSCILLATION; ULTRASOUND SCANNERS; WAVE FORMS;

EID: 84863705764     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2012.2349     Document Type: Article
Times cited : (41)

References (39)
  • 4
    • 84865221001 scopus 로고    scopus 로고
    • Lecoeur Electronique (2006). Users guide for OPEN system. [Online]. Available: http://lecoeur-electronique.net/cariboost-files/user-27s-20guide- 20for-20open-20system.pdf
    • (2006) Users Guide for OPEN System
  • 7
    • 77950904872 scopus 로고    scopus 로고
    • A highly customizable ultrasound research platform for clinical use with a software architecture for 2d-/3d-re-construction and processing including closed-loop control
    • H. J. Hewener, H. J. Welsch, C. Gnther, H. Fonfara, S. H. Tret-bar, and R. M. Lemor, "A highly customizable ultrasound research platform for clinical use with a software architecture for 2d-/3d-re-construction and processing including closed-loop control," IFMBE Proc, vol. 25, no. 2, pp. 342-345, 2009.
    • (2009) IFMBE Proc , vol.25 , Issue.2 , pp. 342-345
    • Hewener, H.J.1    Welsch, H.J.2    Gnther, C.3    Fonfara, H.4    Tretbar, S.H.5    Lemor, R.M.6
  • 11
    • 84865254801 scopus 로고    scopus 로고
    • Information for manufacturers seeking marketing clearance of diagnostic ultrasound systems and transducers
    • U.S. Food and Drug Administration Silver Spring, MD
    • U.S. Food and Drug Administration, "Information for manufacturers seeking marketing clearance of diagnostic ultrasound systems and transducers," Center for Devices and Radiological Health, United States Food and Drug Administration, Silver Spring, MD, 1997.
    • (1997) Center for Devices and Radiological Health, United States Food and Drug Administration
  • 12
    • 0026838720 scopus 로고
    • Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers
    • J. A. Jensen and N. B. Svendsen, "Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 39, no. 2, pp. 262-267, 1992.
    • (1992) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.39 , Issue.2 , pp. 262-267
    • Jensen, J.A.1    Svendsen, N.B.2
  • 13
    • 24044478820 scopus 로고    scopus 로고
    • Field: A program for simulating ultrasound systems
    • pt. 1
    • J. A. Jensen, "Field: A program for simulating ultrasound systems," Med. Biol. Eng. Gomput., vol. 34, suppl. 1, pt. 1, pp. 351-353, 1996.
    • (1996) Med. Biol. Eng. Gomput. , vol.34 , Issue.SUPPL. 1 , pp. 351-353
    • Jensen, J.A.1
  • 14
    • 0030196861 scopus 로고    scopus 로고
    • A 100-MHz ultrasound imaging system for dermatologie and ophthalmologic diagnostics
    • PII S0885301096049568
    • C. Passmann and H. Ermert, "A 100-MHz ultrasound imaging system for dermatologic and ophthalmologic diagnostics," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 43, no. 4, pp. 545-552, 1996. (Pubitemid 126781052)
    • (1996) IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control , vol.43 , Issue.4 , pp. 545-552
    • Passmann, C.1    Ermert, H.2
  • 17
    • 0034580075 scopus 로고    scopus 로고
    • 3D synthetic aperture imaging using a virtual source element in the elevation plane
    • S. I. Nikolov and J. A. Jensen, "3D synthetic aperture imaging using a virtual source element in the elevation plane," in Proc. IEEE Ultrason. Symp., 2000, vol. 2, pp. 1743-1747. (Pubitemid 34082566)
    • (2000) Proceedings of the IEEE Ultrasonics Symposium , vol.2 , pp. 1743-1747
    • Nikolov, S.I.1    Jensen, J.A.2
  • 18
    • 0034315840 scopus 로고    scopus 로고
    • A study of synthetic-aperture imaging with virtual source elements in B-mode ultrasound imaging systems
    • M. H. Bae and M. K. Jeong, "A study of synthetic-aperture imaging with virtual source elements in B-mode ultrasound imaging systems," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 47, no. 6, pp. 1510-1519, 2000.
    • (2000) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.47 , Issue.6 , pp. 1510-1519
    • Bae, M.H.1    Jeong, M.K.2
  • 20
    • 84865252639 scopus 로고    scopus 로고
    • Synthetic aperture sequential beamformation applied to medical imaging using a multi element convex array transducer
    • to be published
    • M. C. Hemmsen, J. M. Hansen, and J. A. Jensen, "Synthetic aperture sequential beamformation applied to medical imaging using a multi element convex array transducer," in 9th European Conf. Synthetic Aperture Radar, 2012, to be published.
    • (2012) 9th European Conf. Synthetic Aperture Radar
    • Hemmsen, M.C.1    Hansen, J.M.2    Jensen, J.A.3
  • 21
    • 79957957459 scopus 로고    scopus 로고
    • An object-oriented multi-threaded software beamformation toolbox
    • Orlando, FL, 2011, art. no. 79680Y
    • J. M. Hansen and J. A. Jensen, "An object-oriented multi-threaded software beamformation toolbox," 2011, in Proc. SPIE Medical Imaging, Orlando, FL, 2011, art. no. 79680Y.
    • (2011) Proc. SPIE Medical Imaging
    • Hansen, J.M.1    Jensen, J.A.2
  • 23
    • 0017904851 scopus 로고
    • Multiple crossed-beam ultrasound Doppler velocimetry
    • M. D. Fox, "Multiple crossed-beam ultrasound Doppler velocimetry," IEEE Trans. Sonics Ultrason., vol. SU-25, no. 5, pp. 281-286, 1978. (Pubitemid 8404660)
    • (1978) IEEE Transactions on Sonics and Ultrasonics , vol.25 , Issue.5 , pp. 281-286
    • Fox, M.D.1
  • 25
    • 0023431409 scopus 로고
    • Ultrasound doppler probing of flows transverse with respect to beam axis
    • V. L. Newhouse, D. Censor, T. Vontz, J. A. Cisneros, and B. B. Goldberg, "Ultrasound Doppler probing of flows transverse with respect to beam axis," IEEE Trans. Biomed. Eng., vol. BME-34, no. 10, pp. 779-789, 1987.
    • (1987) IEEE Trans. Biomed. Eng. , vol.34 BME , Issue.10 , pp. 779-789
    • Newhouse, V.L.1    Censor, D.2    Vontz, T.3    Cisneros, J.A.4    Goldberg, B.B.5
  • 26
    • 0024170376 scopus 로고
    • Measurement of the complete (3D) velocity vector of blood flows
    • O. Bonnefous, "Measurement of the complete (3D) velocity vector of blood flows," in Proc. IEEE Ultrason. Symp., 1988, pp. 795-799.
    • (1988) Proc. IEEE Ultrason. Symp. , pp. 795-799
    • Bonnefous, O.1
  • 27
    • 0042140714 scopus 로고    scopus 로고
    • Directional velocity estimation using focusing along the flow direction: I: Theory and simulation
    • J. A. Jensen, "Directional velocity estimation using focusing along the flow direction: I: Theory and simulation," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 50, no. 7, pp. 857-872, 2003.
    • (2003) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.50 , Issue.7 , pp. 857-872
    • Jensen, J.A.1
  • 29
    • 0032072540 scopus 로고    scopus 로고
    • Multi-dimensional velocity estimation with ultrasound using spatial quadrature
    • M. E. Anderson, "Multi-dimensional velocity estimation with ultrasound using spatial quadrature," IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 45, no. 3, pp. 852-861, 1998.
    • (1998) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.45 , Issue.3 , pp. 852-861
    • Anderson, M.E.1
  • 31
    • 33947604016 scopus 로고    scopus 로고
    • Examples of in vivo blood vector velocity estimation
    • DOI 10.1016/j.ultrasmedbio.2006.10.014, PII S0301562906018679
    • J. Udesen, M. B. Nielsen, K. R. Nielsen, and J. A. Jensen, "Examples of in vivo blood vector velocity estimation," Ultrasound Med. Biol., vol. 33, no. 4, pp. 541-548, 2007. (Pubitemid 46476829)
    • (2007) Ultrasound in Medicine and Biology , vol.33 , Issue.4 , pp. 541-548
    • Udesen, J.1    Nielsen, M.B.2    Nielsen, K.R.3    Jensen, J.A.4
  • 33
    • 84955046193 scopus 로고
    • Ultrasonic doppler method for the inspection of cardiac functions
    • S. Satomura, "Ultrasonic Doppler method for the inspection of cardiac functions," J. Acoust. Soc. Am., vol. 29, no. 11, pp. 1181-1185, 1957.
    • (1957) J. Acoust. Soc. Am. , vol.29 , Issue.11 , pp. 1181-1185
    • Satomura, S.1
  • 34
    • 0014797429 scopus 로고
    • Pulsed ultrasonic doppler blood-flow sensing
    • D. W. Baker, "Pulsed ultrasonic Doppler blood-flow sensing," IEEE Trans. Sonics Ultrason., vol. SU-17, no. 3, pp. 170-185, 1970.
    • (1970) IEEE Trans. Sonics Ultrason. , vol.17 SU , Issue.3 , pp. 170-185
    • Baker, D.W.1
  • 36
    • 0034351105 scopus 로고    scopus 로고
    • Numerical simulation and experimental validation of blood flow in arteries with structured-tree outflow conditions
    • DOI 10.1114/1.1326031
    • M. S. Olufsen, C. S. Peskin, W. Y. Kim, E. M. Pedersen, A. Nadim, and J. Larsen, "Numerical simulation and experimental validation of blood flow in arteries with structured-tree outflow conditions," Ann. Biomed. Eng., vol. 28, no. 11, pp. 1281-1299, 2000. (Pubitemid 32872598)
    • (2000) Annals of Biomedical Engineering , vol.28 , Issue.11 , pp. 1281-1299
    • Olufsen, M.S.1    Peskin, C.S.2    Kim, W.Y.3    Pedersen, E.M.4    Nadim, A.5    Larsen, J.6
  • 38
    • 0035692648 scopus 로고    scopus 로고
    • Fluid-structure interaction within realistic three-dimensional models of the aneurysmatic aorta as a guidance to assess the risk of rupture of the aneurysm
    • DOI 10.1016/S1350-4533(01)00093-5, PII S1350453301000935
    • E. Di Martino, G. Guadagni, A. Fumero, G. Ballerini, R. Spirito, P. Biglioli, and A. Redaelli, "Fluid-structure interaction within realistic three-dimensional models of the aneurysmatic aorta as a guidance to assess the risk of rupture of the aneurysm," Med. Eng. Phys., vol. 23, no. 9, pp. 647-655, 2001. (Pubitemid 34072902)
    • (2001) Medical Engineering and Physics , vol.23 , Issue.9 , pp. 647-655
    • Di Martino, E.S.1    Guadagni, G.2    Fumero, A.3    Ballerini, G.4    Spirito, R.5    Biglioli, P.6    Redaelli, A.7
  • 39
    • 34547610612 scopus 로고
    • Mechanics of the circulation
    • A. Guyton, Ed. Cambridge, UK: Cambridge University Press
    • C. G. Caro, T. J. Pedley, R. C. Schroter, and W. A. Seed, "Mechanics of the circulation," in Cardiovascular Physiology, A. Guyton, Ed. Cambridge, UK: Cambridge University Press, 1974.
    • (1974) Cardiovascular Physiology
    • Caro, C.G.1    Pedley, T.J.2    Schroter, R.C.3    Seed, W.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.