Diagnostic X-ray shielding design based on an empirical model of photon attenuation
Archer B R, Thornby J I and Bushong S C 1983 Diagnostic x-ray shielding design based on an empirical model of photon attenuation Health Phys. 44 507-17 (Pubitemid 13064495)
A large-scale multicentre study in Belgium of dose area product values and effective doses in interventional cardiology using contemporary X-ray equipment
DOI 10.1093/rpd/ncm379
Bogaert E, Bacher K and Thierens H 2008 A large-scale multicentre study in Belgium of dose area product values and effective doses in interventional cardiology using contemporary x-ray equipment Radiat. Prot. Dosim. 128 312-23 (Pubitemid 351827487)
Investigation of the practical aspects of an additional 0.1mm copper x-ray spectral filter for cine acquisition mode imaging in a clinical care setting
10.1097/HP.0b013e3181d96964 0017-9078
Fetterly K A 2010 Investigation of the practical aspects of an additional 0.1mm copper x-ray spectral filter for cine acquisition mode imaging in a clinical care setting Health Phys. 99 624-30
The operation logic of automatic dose control of fluoroscopy system in conjunction with spectral shaping filters
DOI 10.1118/1.2752576
Lin P J 2007 The operation logic of automatic dose control of fluoroscopy system in conjunction with spectral shaping filters Med. Phys. 34 3169-72 (Pubitemid 47175782)
NCRP 2005 NCRP Report 147 Structural Shielding Design for Medical X-ray Imaging Facilities (Bethesda, MD: National Council on Radiation Protection and Measurements)
Optimization of radiographic parameters for paediatric cardiac angiography
DOI 10.1259/bjr/99356178
Onnasch D G, Schemm A and Kramer H H 2004 Optimization of radiographic parameters for paediatric cardiac angiography Br. J. Radiol. 77 479-87 (Pubitemid 38807562)
Evaluation of NCRP Report no. 49 assumptions on workloads and use factors in diagnostic radiology facilities
DOI 10.1118/1.597813
Simpkin D J 1996 Evaluation of NCRP Report No. 49 assumptions on workloads and use factors in diagnostic radiology facilities Med. Phys. 23 577-84 (Pubitemid 26120159)
Secondary shielding barriers for diagnostic X-ray facilities: Scatter and leakage revisited
Simpkin D J and Dixon R L 1998 Secondary shielding barriers for diagnostic x-ray facilities: scatter and leakage revisited Health Phys. 74 350-65 (Pubitemid 28103515)
Scatter dose estimation based on dose-area product and the specification of radiation barriers
Williams J R 1996 Scatter dose estimation based on dose-area product and the specification of radiation barriers Br. J. Radiol. 69 1032-7 (Pubitemid 26388609)