메뉴 건너뛰기




Volumn 191, Issue 4, 2008, Pages

Use of 3D adaptive raw-data filter in CT of the lung: Effect on radiation dose reduction

(22)  Kubo, Takeshi a,b,g   Ohno, Yoshiharu c,g   Gautam, Shiva a,g   Lin, Pei Jan P a,g   Kauczor, Hans Ulrich d,e,g   Hatabu, Hiroto f,g   Takahashi, Masaya g   Nishino, Mizuki g   Sitek, Arkadiusz g   Takenaka, Daisuke g   Nogami, Munenobu g   Koyama, Hisanobu g   Ley Zaporozhan, Julia g   Stiller, Wolfram g   Ley, Sebastian g   Inokawa, Hiroyasu g   Okumura, Miwa g   Fujisawa, Yasuko g   Kura, Hiroyuki g   Rifu, Toshihiro g   more..

g NONE

Author keywords

Artifacts; Chest CT; Imaging filter; Radiation dose

Indexed keywords

ADULT; AGED; ARTICLE; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; FEMALE; HUMAN; IMAGE QUALITY; LUNG; LUNG LOBE; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; RADIATION DOSE;

EID: 53249140708     PISSN: 0361803X     EISSN: None     Source Type: Journal    
DOI: 10.2214/AJR/07.2630     Document Type: Article
Times cited : (28)

References (14)
  • 2
    • 2442444413 scopus 로고    scopus 로고
    • UK population dose from medical x-ray examinations
    • Hart D, Wall BF. UK population dose from medical x-ray examinations. Eur J Radiol 2004; 50:285-291
    • (2004) Eur J Radiol , vol.50 , pp. 285-291
    • Hart, D.1    Wall, B.F.2
  • 3
    • 53249137090 scopus 로고    scopus 로고
    • Federal Office for Radiation Protection. Environmental radioactivity and radiation exposure in the year 2005 (parliamentary report). www.bfs.de/en/bfs/ druck/uus/parlamentsbericht03.pdf. Salzgitter, Germany: Federal Office for Radiation Protection, 2005. Accessed June 28, 2008
    • Federal Office for Radiation Protection. Environmental radioactivity and radiation exposure in the year 2005 (parliamentary report). www.bfs.de/en/bfs/ druck/uus/parlamentsbericht03.pdf. Salzgitter, Germany: Federal Office for Radiation Protection, 2005. Accessed June 28, 2008
  • 4
    • 11344266878 scopus 로고    scopus 로고
    • Radiation dose in computed tomography of the chest
    • Tack D, Gevenois PA. Radiation dose in computed tomography of the chest. JBR-BTR 2004; 87:281-288
    • (2004) JBR-BTR , vol.87 , pp. 281-288
    • Tack, D.1    Gevenois, P.A.2
  • 5
    • 38849084698 scopus 로고    scopus 로고
    • Radiation dose reduction in chest CT: A review
    • Kubo T, Ohno Y, Stiller W, et al. Radiation dose reduction in chest CT: a review. AJR 2008; 190:335-343
    • (2008) AJR , vol.190 , pp. 335-343
    • Kubo, T.1    Ohno, Y.2    Stiller, W.3
  • 6
    • 0037600566 scopus 로고    scopus 로고
    • Can noise reduction filters improve low-radiation-dose chest CT images? Pilot study
    • Kalra MK, Wittram C, Maher MM, et al. Can noise reduction filters improve low-radiation-dose chest CT images? Pilot study. Radiology 2003; 228:257-264
    • (2003) Radiology , vol.228 , pp. 257-264
    • Kalra, M.K.1    Wittram, C.2    Maher, M.M.3
  • 7
    • 0035052748 scopus 로고    scopus 로고
    • Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT
    • Kachelriess M, Watzke O, Kalender WA. Generalized multi-dimensional adaptive filtering for conventional and spiral single-slice, multi-slice, and cone-beam CT. Med Phys 2001; 28:475-490
    • (2001) Med Phys , vol.28 , pp. 475-490
    • Kachelriess, M.1    Watzke, O.2    Kalender, W.A.3
  • 8
    • 33750685698 scopus 로고    scopus 로고
    • 3-Dimensional adaptive raw-data filter: Evaluation in low dose chest multidetector-row computed tomography
    • Kubo T, Nishino M, Kino A, et al. 3-Dimensional adaptive raw-data filter: evaluation in low dose chest multidetector-row computed tomography. J Comput Assist Tomogr 2006; 30:933-938
    • (2006) J Comput Assist Tomogr , vol.30 , pp. 933-938
    • Kubo, T.1    Nishino, M.2    Kino, A.3
  • 9
    • 33750116653 scopus 로고    scopus 로고
    • New method of evaluating edge-preserving adaptive filters for computed tomography (CT): Digital phantom method
    • Okumura M, Ota T, Tsukagoshi S, Katada K. New method of evaluating edge-preserving adaptive filters for computed tomography (CT): digital phantom method. Nippon Hoshasen Gijutsu Gakkai Zasshi 2006; 62:971-978
    • (2006) Nippon Hoshasen Gijutsu Gakkai Zasshi , vol.62 , pp. 971-978
    • Okumura, M.1    Ota, T.2    Tsukagoshi, S.3    Katada, K.4
  • 10
    • 0037600583 scopus 로고    scopus 로고
    • Low-dose CT of the abdomen: Evaluation of image improvement with use of noise reduction filters - pilot study
    • Kalra MK, Maher MM, Sahani DV, et al. Low-dose CT of the abdomen: evaluation of image improvement with use of noise reduction filters - pilot study. Radiology 2003; 228:251-256
    • (2003) Radiology , vol.228 , pp. 251-256
    • Kalra, M.K.1    Maher, M.M.2    Sahani, D.V.3
  • 11
    • 16644364586 scopus 로고    scopus 로고
    • Reduction of radiation exposure in CT perfusion study using a quantum de-noising filter
    • Sasaki T, Hanari T, Sasaki M, et al. Reduction of radiation exposure in CT perfusion study using a quantum de-noising filter. Nippon Hoshasen Gijutsu Gakkai Zasshi 2004; 60:1688-1693
    • (2004) Nippon Hoshasen Gijutsu Gakkai Zasshi , vol.60 , pp. 1688-1693
    • Sasaki, T.1    Hanari, T.2    Sasaki, M.3
  • 12
    • 33745338448 scopus 로고    scopus 로고
    • Image quality improvement and exposure dose reduction with the combined use of X-ray modulation and Boost3D
    • Flynn MJ, Hsieh J, eds, physics of medical imaging, Bellingham, WA: SPIE
    • Kazama M, Tsukagoshi S, Okumura M. Image quality improvement and exposure dose reduction with the combined use of X-ray modulation and Boost3D. In: Flynn MJ, Hsieh J, eds. Medical imaging 2006: physics of medical imaging, vol. 6142. Bellingham, WA: SPIE, 2006:847-855
    • (2006) Medical imaging 2006 , vol.6142 , pp. 847-855
    • Kazama, M.1    Tsukagoshi, S.2    Okumura, M.3
  • 13
    • 0028939173 scopus 로고
    • CT of the chest: Minimal tube current required for good image quality with the least radiation dose
    • Mayo JR, Hartman TE, Lee KS, Primack SL, Vedal S, Muller NL. CT of the chest: minimal tube current required for good image quality with the least radiation dose. AJR 1995; 164:603-607
    • (1995) AJR , vol.164 , pp. 603-607
    • Mayo, J.R.1    Hartman, T.E.2    Lee, K.S.3    Primack, S.L.4    Vedal, S.5    Muller, N.L.6
  • 14
    • 0031978536 scopus 로고    scopus 로고
    • Low-dose spiral computed tomography of the thorax: Comparison with the standard-dose technique
    • Takahashi M, Maguire WM, Ashtari M, et al. Low-dose spiral computed tomography of the thorax: comparison with the standard-dose technique. Invest Radiol 1998; 33:68-73
    • (1998) Invest Radiol , vol.33 , pp. 68-73
    • Takahashi, M.1    Maguire, W.M.2    Ashtari, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.