Are conventional reconstruction plates equivalent to precontoured locking plates for distal humerus fracture fixation? A biomechanics cadaver study

Author keywords

Biomechanics; Cadaver; Fixation; Humerus fracture; Locking plate

Indexed keywords

BIOMECHANICAL STUDIES; BIOMECHANICAL TESTING; CADAVER; CADAVER STUDY; CYCLIC LOADINGS; DISTAL HUMERUS; FAILURE PROPERTIES; LOCKING PLATE; PARALLEL CONFIGURATION; PLATE CONFIGURATION; PLATE SYSTEMS; PLATE-TYPE; TORSIONAL STIFFNESS;

EID: 84863613868     PISSN: 02680033     EISSN: 18791271     Source Type: Journal    
DOI: 10.1016/j.clinbiomech.2012.03.008     Document Type: Article
Times cited : (28)

References (24)
  • 1
    • 77955479957 scopus 로고    scopus 로고
    • Use of orthogonal or parallel plating techniques to treat distal humerus fractures
    • J.M. Abzug, and P.K. Dantuluri Use of orthogonal or parallel plating techniques to treat distal humerus fractures Hand Clin. 26 2010 411 421
    • (2010) Hand Clin. , vol.26 , pp. 411-421
    • Abzug, J.M.1    Dantuluri, P.K.2
  • 2
  • 3
    • 67649794272 scopus 로고    scopus 로고
    • Management of fractures of the humerus in ancient Egypt, Greece, and Rome
    • S. Brorson Management of fractures of the humerus in ancient Egypt, Greece, and Rome Clin. Orthop. Relat. Res. 467 2009 1907 1914
    • (2009) Clin. Orthop. Relat. Res. , vol.467 , pp. 1907-1914
    • Brorson, S.1
  • 4
    • 64849094442 scopus 로고    scopus 로고
    • Three-dimensional distribution of trabecular bone density and cortical thickness in the distal humerus
    • G. Diederichs, A.S. Issever, S. Greiner, B. Linke, and J. Korner Three-dimensional distribution of trabecular bone density and cortical thickness in the distal humerus J. Shoulder Elbow Surg. 18 2009 399 407
    • (2009) J. Shoulder Elbow Surg. , vol.18 , pp. 399-407
    • Diederichs, G.1    Issever, A.S.2    Greiner, S.3    Linke, B.4    Korner, J.5
  • 5
    • 75949122769 scopus 로고    scopus 로고
    • Current treatment strategies for bicolumnar distal humerus fractures
    • G.J. Galano, C.S. Ahmad, and W.N. Levine Current treatment strategies for bicolumnar distal humerus fractures J. Am. Acad. Orthop. Surg. 18 2010 20 30
    • (2010) J. Am. Acad. Orthop. Surg. , vol.18 , pp. 20-30
    • Galano, G.J.1    Ahmad, C.S.2    Levine, W.N.3
  • 6
    • 67649236304 scopus 로고    scopus 로고
    • Open reduction and internal fixation with 90-90 plating of bicolumn distal humerus fractures
    • A. Green Open reduction and internal fixation with 90-90 plating of bicolumn distal humerus fractures Instr. Course Lect. 58 2009 515 519
    • (2009) Instr. Course Lect. , vol.58 , pp. 515-519
    • Green, A.1
  • 7
    • 0031307726 scopus 로고    scopus 로고
    • Comparison of distal humerus fracture fixation: A biomechanical study
    • S.R. Jacobson, R.R. Glisson, and J.R. Urbaniak Comparison of distal humerus fracture fixation: a biomechanical study J. South. Orthop. Assoc. 6 1997 241 249
    • (1997) J. South. Orthop. Assoc. , vol.6 , pp. 241-249
    • Jacobson, S.R.1    Glisson, R.R.2    Urbaniak, J.R.3
  • 8
    • 59049091060 scopus 로고    scopus 로고
    • The management of nonunion and malunion of the distal humerus - A 30-year experience
    • J.B. Jupiter The management of nonunion and malunion of the distal humerus - a 30-year experience J. Orthop. Trauma 22 2008 742 750
    • (2008) J. Orthop. Trauma , vol.22 , pp. 742-750
    • Jupiter, J.B.1
  • 10
    • 0142138199 scopus 로고    scopus 로고
    • The LCP-concept in the operative treatment of distal humerus fractures - Biological, biomechanical and surgical aspects
    • J. Korner, H. Lill, L.P. Muller, P.M. Rommens, E. Schneider, and B. Linke The LCP-concept in the operative treatment of distal humerus fractures - biological, biomechanical and surgical aspects Injury 34 2003 SB20 SB30
    • (2003) Injury , vol.34
    • Korner, J.1    Lill, H.2    Muller, L.P.3    Rommens, P.M.4    Schneider, E.5    Linke, B.6
  • 11
    • 2642514242 scopus 로고    scopus 로고
    • A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates
    • J. Korner, G. Diederichs, M. Arzdorf, H. Lill, C. Josten, and E. Schneider A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates J. Orthop. Trauma 18 2004 286 293
    • (2004) J. Orthop. Trauma , vol.18 , pp. 286-293
    • Korner, J.1    Diederichs, G.2    Arzdorf, M.3    Lill, H.4    Josten, C.5    Schneider, E.6
  • 13
    • 13844306983 scopus 로고    scopus 로고
    • Optimizing stability in distal humerus fracture fixation
    • S.W. O'Driscoll Optimizing stability in distal humerus fracture fixation J. Shoulder Elbow Surg. 14 2005 186 194
    • (2005) J. Shoulder Elbow Surg. , vol.14 , pp. 186-194
    • O'Driscoll, S.W.1
  • 14
    • 67649202364 scopus 로고    scopus 로고
    • Parallel plate fixation of bicolumn distal humeral fractures
    • S.W. O'Driscoll Parallel plate fixation of bicolumn distal humeral fractures Instr. Course Lect. 25 2009 521 528
    • (2009) Instr. Course Lect. , vol.25 , pp. 521-528
    • O'Driscoll, S.W.1
  • 15
    • 78650187510 scopus 로고    scopus 로고
    • Anatomical plate configuration affects mechanical performance in distal humerus fractures
    • R. Penzkofer, S. Hungerer, F. Wipf, G. von Oldenburg, and P. Augat Anatomical plate configuration affects mechanical performance in distal humerus fractures Clin. Biomech. 25 2010 972 978
    • (2010) Clin. Biomech. , vol.25 , pp. 972-978
    • Penzkofer, R.1    Hungerer, S.2    Wipf, F.3    Von Oldenburg, G.4    Augat, P.5
  • 17
    • 0028710250 scopus 로고
    • Biomechanical evaluation of methods of internal fixation of the distal humerus
    • E.H. Schemitsch, A.F. Tencer, and M.B. Henley Biomechanical evaluation of methods of internal fixation of the distal humerus J. Orthop. Trauma 8 1994 468 475
    • (1994) J. Orthop. Trauma , vol.8 , pp. 468-475
    • Schemitsch, E.H.1    Tencer, A.F.2    Henley, M.B.3
  • 18
    • 41649103119 scopus 로고    scopus 로고
    • Mechanical comparison in cadaver specimens of three different 90-degree double-plate osteosynthesis for simulated C2-type distal humerus fractures with varying bone densities
    • I. Schuster, J. Korner, M. Arzdorf, K. Schwieger, G. Diederichs, and B. Linke Mechanical comparison in cadaver specimens of three different 90-degree double-plate osteosynthesis for simulated C2-type distal humerus fractures with varying bone densities J. Orthop. Trauma 22 2008 113 120
    • (2008) J. Orthop. Trauma , vol.22 , pp. 113-120
    • Schuster, I.1    Korner, J.2    Arzdorf, M.3    Schwieger, K.4    Diederichs, G.5    Linke, B.6
  • 19
    • 33748703840 scopus 로고    scopus 로고
    • Biomechanical comparison of two different periarticular plating systems for stabilization of complex distal humerus fractures
    • A. Schwartz, R. Oka, T. Odell, and A. Mahar Biomechanical comparison of two different periarticular plating systems for stabilization of complex distal humerus fractures Clin. Biomech. 21 2006 950 955
    • (2006) Clin. Biomech. , vol.21 , pp. 950-955
    • Schwartz, A.1    Oka, R.2    Odell, T.3    Mahar, A.4
  • 20
    • 0029205221 scopus 로고
    • A comparison of double-plate fixation methods for complex distal humerus fractures
    • J. Self, S.F. Viegas, J.R. Buford WL, and R.M. Patterson A comparison of double-plate fixation methods for complex distal humerus fractures J. Shoulder Elbow Surg. 4 1995 10 16
    • (1995) J. Shoulder Elbow Surg. , vol.4 , pp. 10-16
    • Self, J.1    Viegas, S.F.2    Buford Wl, J.R.3    Patterson, R.M.4
  • 21
    • 46449133093 scopus 로고    scopus 로고
    • Comparative stability of perpendicular versus parallel double-locking plating systems in osteoporotic comminuted distal humerus fractures
    • K. Stoffel, S. Cunneen, R. Morgan, R. Nicholls, and G. Stachowaik Comparative stability of perpendicular versus parallel double-locking plating systems in osteoporotic comminuted distal humerus fractures J. Orthop. Res. 26 2008 778 784
    • (2008) J. Orthop. Res. , vol.26 , pp. 778-784
    • Stoffel, K.1    Cunneen, S.2    Morgan, R.3    Nicholls, R.4    Stachowaik, G.5
  • 22
    • 68149162956 scopus 로고    scopus 로고
    • Fixation of extra-articular distal humerus fractures using one locking plate versus two reconstruction plates: A laboratory study
    • N.C. Tejwani, A. Murthy, J. Park, T.M. McLaurin, K.A. Egol, and F.J. Kummer Fixation of extra-articular distal humerus fractures using one locking plate versus two reconstruction plates: a laboratory study J. Trauma 66 2009 795 799
    • (2009) J. Trauma , vol.66 , pp. 795-799
    • Tejwani, N.C.1    Murthy, A.2    Park, J.3    McLaurin, T.M.4    Egol, K.A.5    Kummer, F.J.6
  • 23
    • 77955100306 scopus 로고    scopus 로고
    • Treatment of distal humeral fractures using conventional implants. Biomechanical evaluation of a new implant configuration
    • M. Windolf, E.R. Maza, B. Gueorguiev, V. Braunstein, and K. Schwieger Treatment of distal humeral fractures using conventional implants. Biomechanical evaluation of a new implant configuration BMC Musculoskelet. Disord. 11 2010 172 178
    • (2010) BMC Musculoskelet. Disord. , vol.11 , pp. 172-178
    • Windolf, M.1    Maza, E.R.2    Gueorguiev, B.3    Braunstein, V.4    Schwieger, K.5
  • 24
    • 78649876149 scopus 로고    scopus 로고
    • Biomechanical evaluation of parallel versus orthogonal plate fixation of intra-articular distal humerus fractures
    • C.G. Zalavras, M.T. Vercillo, B.J. Jun, K.J. Otarodifard, J.M. Itamura, and T.Q. Lee Biomechanical evaluation of parallel versus orthogonal plate fixation of intra-articular distal humerus fractures J. Shoulder Elbow Surg. 20 2011 12 20
    • (2011) J. Shoulder Elbow Surg. , vol.20 , pp. 12-20
    • Zalavras, C.G.1    Vercillo, M.T.2    Jun, B.J.3    Otarodifard, K.J.4    Itamura, J.M.5    Lee, T.Q.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.