메뉴 건너뛰기




Volumn 25, Issue 10, 2010, Pages 972-978

Anatomical plate configuration affects mechanical performance in distal humerus fractures

Author keywords

Angle stable plates; Biomechanics; Distal humerus fractures

Indexed keywords

ANGLE STABLE PLATES; ARTIFICIAL BONES; BENDING STIFFNESS; BIOMECHANICAL STUDIES; DISTAL HUMERUS; ELBOW JOINTS; FATIGUE LIMIT; FRACTURE MODEL; FRACTURE PATTERN; LOADING MODES; LOADING PROTOCOLS; MECHANICAL PERFORMANCE; PARALLEL CONFIGURATION; PLATE CONFIGURATION; PLATING SYSTEMS; RELATIVE DISPLACEMENT; SAWBONE; SCREW HOLE; TRANSVERSAL PLANES;

EID: 78650187510     PISSN: 02680033     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clinbiomech.2010.07.005     Document Type: Article
Times cited : (55)

References (31)
  • 1
    • 0018947109 scopus 로고
    • Analysis of elbow forces due to high-speed forearm movements
    • A.A. Amis, D. Dowson, and V. Wright Analysis of elbow forces due to high-speed forearm movements J. Biomech. 13 1980 825 831
    • (1980) J. Biomech. , vol.13 , pp. 825-831
    • Amis, A.A.1    Dowson, D.2    Wright, V.3
  • 2
  • 3
    • 34250789798 scopus 로고    scopus 로고
    • Fatigue performance of composite analogue femur constructs under high activity loading
    • A.C. Chong, E.A. Friis, G.P. Ballard, P.J. Czuwala, and F.W. Cooke Fatigue performance of composite analogue femur constructs under high activity loading Ann. Biomed. Eng. 35 2007 1196 1205
    • (2007) Ann. Biomed. Eng. , vol.35 , pp. 1196-1205
    • Chong, A.C.1    Friis, E.A.2    Ballard, G.P.3    Czuwala, P.J.4    Cooke, F.W.5
  • 4
    • 0031194558 scopus 로고    scopus 로고
    • Influence of size and stability of the osteotomy gap on the success of fracture healing
    • L. Claes, P. Augat, G. Suger, and H.J. Wilke Influence of size and stability of the osteotomy gap on the success of fracture healing J. Orthop. Res. 15 1997 577 584
    • (1997) J. Orthop. Res. , vol.15 , pp. 577-584
    • Claes, L.1    Augat, P.2    Suger, G.3    Wilke, H.J.4
  • 5
    • 0028227689 scopus 로고
    • A biomechanical analysis of prophylactic fixation for pathological fractures of the distal third of the humerus
    • T.A. Damron, J.P. Heiner, E.M. Freund, L.A. Damron, R. McCabe, and R. Vanderby A biomechanical analysis of prophylactic fixation for pathological fractures of the distal third of the humerus J. Bone Joint Surg. Am. 76 1994 839 847
    • (1994) J. Bone Joint Surg. Am. , vol.76 , pp. 839-847
    • Damron, T.A.1    Heiner, J.P.2    Freund, E.M.3    Damron, L.A.4    McCabe, R.5    Vanderby, R.6
  • 7
    • 54849433115 scopus 로고    scopus 로고
    • Structural properties of a novel design of composite analogue humeri models
    • J.T. Dunlap, A.C. Chong, G.L. Lucas, and F.W. Cooke Structural properties of a novel design of composite analogue humeri models Ann. Biomed. Eng. 36 2008 1922 1926
    • (2008) Ann. Biomed. Eng. , vol.36 , pp. 1922-1926
    • Dunlap, J.T.1    Chong, A.C.2    Lucas, G.L.3    Cooke, F.W.4
  • 8
    • 44649141206 scopus 로고    scopus 로고
    • Outcome after open reduction and angular stable internal fixation for supra-intercondylar fractures of the distal humerus: Preliminary results with the LCP distal humerus system
    • S. Greiner, N.P. Haas, and H.J. Bail Outcome after open reduction and angular stable internal fixation for supra-intercondylar fractures of the distal humerus: preliminary results with the LCP distal humerus system Arch. Orthop. Trauma. Surg. 128 2008 723 729
    • (2008) Arch. Orthop. Trauma. Surg. , vol.128 , pp. 723-729
    • Greiner, S.1    Haas, N.P.2    Bail, H.J.3
  • 10
    • 0001689504 scopus 로고
    • Transmission of pressures across the elbow joint
    • A.A. Halls, and A. Travill Transmission of pressures across the elbow joint Anat. Rec. 150 1964 243 247
    • (1964) Anat. Rec. , vol.150 , pp. 243-247
    • Halls, A.A.1    Travill, A.2
  • 11
    • 0025140064 scopus 로고
    • Internal fixation of the distal humerus: A biomechanical comparison of methods
    • D.L. Helfet, and R.N. Hotchkiss Internal fixation of the distal humerus: a biomechanical comparison of methods J. Orthop. Trauma 4 1990 260 264
    • (1990) J. Orthop. Trauma , vol.4 , pp. 260-264
    • Helfet, D.L.1    Hotchkiss, R.N.2
  • 12
    • 0029176951 scopus 로고
    • Complex fractures of the distal part of the humerus and associated complications
    • J.B. Jupiter Complex fractures of the distal part of the humerus and associated complications Instr. Course Lect. 44 1995 187 198
    • (1995) Instr. Course Lect. , vol.44 , pp. 187-198
    • Jupiter, J.B.1
  • 14
    • 0142138199 scopus 로고    scopus 로고
    • The LCP-concept in the operative treatment of distal humerus fractures-biological, biomechanical and surgical aspects
    • J. Korner, H. Lill, L.P. Muller, P.M. Rommens, E. Schneider, and B. Linke The LCP-concept in the operative treatment of distal humerus fractures-biological, biomechanical and surgical aspects Injury 34 Suppl 2 2003 B20 B30
    • (2003) Injury , vol.34 , Issue.SUPPL. 2
    • Korner, J.1    Lill, H.2    Muller, L.P.3    Rommens, P.M.4    Schneider, E.5    Linke, B.6
  • 15
    • 2642514242 scopus 로고    scopus 로고
    • A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates
    • J. Korner, G. Diederichs, M. Arzdorf, H. Lill, C. Josten, and E. Schneider A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates J. Orthop. Trauma 18 2004 286 293
    • (2004) J. Orthop. Trauma , vol.18 , pp. 286-293
    • Korner, J.1    Diederichs, G.2    Arzdorf, M.3    Lill, H.4    Josten, C.5    Schneider, E.6
  • 16
    • 26944463132 scopus 로고    scopus 로고
    • Distal humerus fractures in elderly patients: Results after open reduction and internal fixation
    • J. Korner, H. Lill, L.P. Muller, M. Hessmann, K. Kopf, and J. Goldhahn Distal humerus fractures in elderly patients: results after open reduction and internal fixation Osteoporos. Int. 16 Suppl 2 2005 S73 S79
    • (2005) Osteoporos. Int. , vol.16 , Issue.SUPPL. 2
    • Korner, J.1    Lill, H.2    Muller, L.P.3    Hessmann, M.4    Kopf, K.5    Goldhahn, J.6
  • 17
    • 78650207946 scopus 로고
    • STP 731Tables for Estimating Median Fatigue Limits; ASTM Special Technical Publication 731
    • University of Michigan DC, editor 1916 Race Street, Philadelphia, Pa. 19103
    • Little, R.E., 1981. STP 731Tables for Estimating Median Fatigue Limits; ASTM Special Technical Publication 731. In: University of Michigan DC, editor.ASTM American Society for Testing and Materials, 1916 Race Street, Philadelphia, Pa. 19103
    • (1981) ASTM American Society for Testing and Materials
    • Little, R.E.1
  • 18
  • 21
    • 0031909491 scopus 로고    scopus 로고
    • Secular trends in the osteoporotic fractures of the distal humerus in elderly women
    • M. Palvanen, P. Kannus, S. Niemi, and J. Parkkari Secular trends in the osteoporotic fractures of the distal humerus in elderly women Eur. J. Epidemiol. 14 1998 159 164
    • (1998) Eur. J. Epidemiol. , vol.14 , pp. 159-164
    • Palvanen, M.1    Kannus, P.2    Niemi, S.3    Parkkari, J.4
  • 24
    • 34248225258 scopus 로고    scopus 로고
    • Complex distal humeral fractures: Internal fixation with a principle-based parallel-plate technique
    • J. Sanchez-Sotelo, M.E. Torchia, and S.W. O'Driscoll Complex distal humeral fractures: internal fixation with a principle-based parallel-plate technique J. Bone Joint Surg. Am. 89 2007 961 969
    • (2007) J. Bone Joint Surg. Am. , vol.89 , pp. 961-969
    • Sanchez-Sotelo, J.1    Torchia, M.E.2    O'Driscoll, S.W.3
  • 25
    • 0028710250 scopus 로고
    • Biomechanical evaluation of methods of internal fixation of the distal humerus
    • E.H. Schemitsch, A.F. Tencer, and M.B. Henley Biomechanical evaluation of methods of internal fixation of the distal humerus J. Orthop. Trauma 8 1994 468 475
    • (1994) J. Orthop. Trauma , vol.8 , pp. 468-475
    • Schemitsch, E.H.1    Tencer, A.F.2    Henley, M.B.3
  • 27
    • 41649103119 scopus 로고    scopus 로고
    • Mechanical comparison in cadaver specimens of three different 90-degree double-plate osteosyntheses for simulated C2-type distal humerus fractures with varying bone densities
    • I. Schuster, J. Korner, M. Arzdorf, K. Schwieger, G. Diederichs, and B. Linke Mechanical comparison in cadaver specimens of three different 90-degree double-plate osteosyntheses for simulated C2-type distal humerus fractures with varying bone densities J. Orthop. Trauma 22 2008 113 120
    • (2008) J. Orthop. Trauma , vol.22 , pp. 113-120
    • Schuster, I.1    Korner, J.2    Arzdorf, M.3    Schwieger, K.4    Diederichs, G.5    Linke, B.6
  • 28
    • 33748703840 scopus 로고    scopus 로고
    • Biomechanical comparison of two different periarticular plating systems for stabilization of complex distal humerus fractures
    • A. Schwartz, R. Oka, T. Odell, and A. Mahar Biomechanical comparison of two different periarticular plating systems for stabilization of complex distal humerus fractures Clin. Biomech. 21 2006 950 955
    • (2006) Clin. Biomech. , vol.21 , pp. 950-955
    • Schwartz, A.1    Oka, R.2    Odell, T.3    Mahar, A.4
  • 29
    • 0029205221 scopus 로고
    • A comparison of double-plate fixation methods for complex distal humerus fractures
    • J. Self, S.F. Viegas, W.L. Buford, and R.M. Patterson A comparison of double-plate fixation methods for complex distal humerus fractures J. Shoulder Elbow Surg. 4 1995 10 16
    • (1995) J. Shoulder Elbow Surg. , vol.4 , pp. 10-16
    • Self, J.1    Viegas, S.F.2    Buford, W.L.3    Patterson, R.M.4
  • 30
    • 18144399337 scopus 로고    scopus 로고
    • Fractures of the distal humerus in the elderly: Is internal fixation the treatment of choice?
    • K. Srinivasan, M. Agarwal, S.J. Matthews, and P.V. Giannoudis Fractures of the distal humerus in the elderly: is internal fixation the treatment of choice? Clin. Orthop. Relat. Res. 2005 222 230
    • (2005) Clin. Orthop. Relat. Res. , pp. 222-230
    • Srinivasan, K.1    Agarwal, M.2    Matthews, S.J.3    Giannoudis, P.V.4
  • 31
    • 46449133093 scopus 로고    scopus 로고
    • Comparative stability of perpendicular versus parallel double-locking plating systems in osteoporotic comminuted distal humerus fractures
    • K. Stoffel, S. Cunneen, R. Morgan, R. Nicholls, and G. Stachowiak Comparative stability of perpendicular versus parallel double-locking plating systems in osteoporotic comminuted distal humerus fractures J. Orthop. Res. 26 2008 778 784
    • (2008) J. Orthop. Res. , vol.26 , pp. 778-784
    • Stoffel, K.1    Cunneen, S.2    Morgan, R.3    Nicholls, R.4    Stachowiak, G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.