Clinical assessment of noninvasive intracranial pressure absolute value measurement method

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ADULT; AGED; ARTERY BLOOD FLOW; ARTICLE; CEREBROSPINAL FLUID PRESSURE; CLINICAL ASSESSMENT; CONTROLLED STUDY; DOPPLER ECHOGRAPHY; FEMALE; GOLD STANDARD; GUILLAIN BARRE SYNDROME; HUMAN; HYDROCEPHALUS; IDIOPATHIC INTRACRANIAL HYPERTENSION; INTRACRANIAL PRESSURE MONITORING; LUMBAR PUNCTURE; MAJOR CLINICAL STUDY; MALE; MULTIPLE SCLEROSIS; NON INVASIVE PROCEDURE; OPHTHALMIC ARTERY; POLYNEUROPATHY; PRIORITY JOURNAL; SYSTEMATIC ERROR;

EID: 84863607126     PISSN: 00283878     EISSN: 1526632X     Source Type: Journal    
DOI: 10.1212/WNL.0b013e3182574f50     Document Type: Article
Times cited : (98)

References (24)
  • 1
    • 77951624555 scopus 로고    scopus 로고
    • Noninvasive monitoring of intracranial pressure
    • Popovic D, Khoo M, Lee S. Noninvasive monitoring of intracranial pressure. Recent Patents Biomed Eng 2009;2: 165-179.
    • (2009) Recent Patents Biomed Eng , vol.2 , pp. 165-179
    • Popovic, D.1    Khoo, M.2    Lee, S.3
  • 3
    • 78651161885 scopus 로고
    • Transmission of increased intracranial pressure within the craniospinal axis
    • Langfitt TW, Weinstein JD, Kassell NF, Simeone FA. Transmission of increased intracranial pressure within the craniospinal axis. J Neurosurg 1964;21:989-997.
    • (1964) J Neurosurg , vol.21 , pp. 989-997
    • Langfitt, T.W.1    Weinstein, J.D.2    Kassell, N.F.3    Simeone, F.A.4
  • 4
    • 33846058376 scopus 로고    scopus 로고
    • CSF pressure assessed by lumbar puncture agrees with intracranial pressure
    • Lenfeldt N, Koskinen L, Bergenheim A, Malm J, Eklund A. CSF pressure assessed by lumbar puncture agrees with intracranial pressure. Neurology 2007;68:155-158.
    • (2007) Neurology , vol.68 , pp. 155-158
    • Lenfeldt, N.1    Koskinen, L.2    Bergenheim, A.3    Malm, J.4    Eklund, A.5
  • 5
    • 0035132985 scopus 로고    scopus 로고
    • Idiopathic intracranial hypertension (pseudotumor cerebri): A reappraisal
    • Digre KB, Corbett JJ. Idiopathic intracranial hypertension (pseudotumor cerebri): A reappraisal. Neurologist 2001;7: 2-67.
    • (2001) Neurologist , vol.7 , pp. 2-67
    • Digre, K.B.1    Corbett, J.J.2
  • 6
    • 85031184796 scopus 로고    scopus 로고
    • American College of Surgeons. Head Trauma. Chicago, IL: American College of Surgeons; 1997;181-206
    • American College of Surgeons. Head Trauma. Chicago, IL: American College of Surgeons; 1997;181-206.
  • 7
    • 0034202511 scopus 로고    scopus 로고
    • American Association of Neurological Surgeons, Joint Section on Neurotrauma and Critical Care. Initial management
    • Brain Injury Foundation, American Association of Neurological Surgeons, Joint Section on Neurotrauma and Critical Care. Initial management. J Neurotrauma 2000;17: 463-469.
    • (2000) J Neurotrauma , vol.17 , pp. 463-469
    • Foundation, B.I.1
  • 8
    • 0021959364 scopus 로고
    • Prognosis in middle cerebral artery occlusion
    • Moulin DE, Lo R, Chiang J, et al. Prognosis in middle cerebral artery occlusion. Stroke 1985;16:282-284.
    • (1985) Stroke , vol.16 , pp. 282-284
    • Moulin, D.E.1    Lo, R.2    Chiang, J.3
  • 9
    • 34249901304 scopus 로고    scopus 로고
    • American Association of Neurological Surgeons, Joint Section on Neurotrauma and Critical Care. Indications for intracranial pressure monitoring
    • Brain Trauma Foundation, American Association of Neurological Surgeons, Joint Section on Neurotrauma and Critical Care. Indications for intracranial pressure monitoring. J Neurotrauma 2007;24:S37-S44.
    • (2007) J Neurotrauma , vol.24
    • Foundation, B.T.1
  • 10
    • 52249113118 scopus 로고    scopus 로고
    • Use of T2-weighted MRI of the optic nerve sheath to detect raised intracranial pressure
    • Geeraerts T, Newcome VF, Coles JP, et al. Use of T2-weighted MRI of the optic nerve sheath to detect raised intracranial pressure. Crit Care 2008;12:R114.
    • (2008) Crit Care , vol.12
    • Geeraerts, T.1    Newcome, V.F.2    Coles, J.P.3
  • 13
    • 51449090524 scopus 로고    scopus 로고
    • Effect of intracranial pressure on the diameter of the optic nerve sheath
    • Watanabe A, Kinouchi H, Horikoshi T, Uchida M, Ishigame K. Effect of intracranial pressure on the diameter of the optic nerve sheath. J Neurosurg 2008;109: 255-258.
    • (2008) J Neurosurg , vol.109 , pp. 255-258
    • Watanabe, A.1    Kinouchi, H.2    Horikoshi, T.3    Uchida, M.4    Ishigame, K.5
  • 14
    • 48949120171 scopus 로고    scopus 로고
    • Noninvasive monitoring of cerebral perfusion pressure in patients with acute liver failure using transcranial Doppler ultrasonography
    • Aggarwal S, Brooks DM, Kang Y, Linden PK, Patzer JF. Noninvasive monitoring of cerebral perfusion pressure in patients with acute liver failure using transcranial Doppler ultrasonography. Liver Transpl 2008;14:1048-1057.
    • (2008) Liver Transpl , vol.14 , pp. 1048-1057
    • Aggarwal, S.1    Brooks, D.M.2    Kang, Y.3    Linden, P.K.4    Patzer, J.F.5
  • 15
    • 0037227036 scopus 로고    scopus 로고
    • Adaptive noninvasive assessment of intracranial pressure and cerebral autoregulation
    • Schmidt B, Czosnyka M, et al. Adaptive noninvasive assessment of intracranial pressure and cerebral autoregulation. Stroke 2003;34:84-89.
    • (2003) Stroke , vol.34 , pp. 84-89
    • Schmidt, B.1    Czosnyka, M.2
  • 17
    • 0033693419 scopus 로고    scopus 로고
    • MR intracranial pressure (ICP): A method for noninvasive measurement of intracranial pressure and elastance: Baboon and human study
    • Alperin N, Lee SH, Loth F, Raksin P, Lichtor T. MR intracranial pressure (ICP): A method for noninvasive measurement of intracranial pressure and elastance: Baboon and human study. Radiology 2000;217:877-885.
    • (2000) Radiology , vol.217 , pp. 877-885
    • Alperin, N.1    Lee, S.H.2    Loth, F.3    Raksin, P.4    Lichtor, T.5
  • 18
    • 0033623093 scopus 로고    scopus 로고
    • Venous ophthalmodynamometry: A noninvasive method for assessment of intracranial pressure
    • Firsching R, Schultze R, Motschmann M, Behrens-Baumann W. Venous ophthalmodynamometry: A noninvasive method for assessment of intracranial pressure. J Neurosurg 2000;93: 33-36.
    • (2000) J Neurosurg , vol.93 , pp. 33-36
    • Firsching, R.1    Schultze, R.2    Motschmann, M.3    Behrens-Baumann, W.4
  • 20
    • 85031186457 scopus 로고    scopus 로고
    • Joint Committee for Guides in Metrology. International Vocabulary of Metrology: Basic and General Concepts and Associated Terms (VIM), 3rd ed. JGCM 200:2012. Available at, Accessed April 19
    • Joint Committee for Guides in Metrology. International Vocabulary of Metrology: Basic and General Concepts and Associated Terms (VIM), 3rd ed. JGCM 200:2012. Available at: Http://www.bipm.org/utils/common/documents/jcgm/JCGM- 200-2012.pdf. Accessed April 19, 2012.
    • (2012)
  • 21
    • 85052610061 scopus 로고    scopus 로고
    • Innovative non-invasive method for absolute intracranial pressure measurement without calibration
    • Ragauskas A, Daubaris G, Dziugys A, Azelis V, Gedrimas V. Innovative non-invasive method for absolute intracranial pressure measurement without calibration. Acta Neurochir Suppl 2005;95:357-361.
    • (2005) Acta Neurochir Suppl , vol.95 , pp. 357-361
    • Ragauskas, A.1    Daubaris, G.2    Dziugys, A.3    Azelis, V.4    Gedrimas, V.5
  • 22
    • 0012053959 scopus 로고
    • Continuous recording and control of ventricular fluid pressure in neurosurgical practice
    • Lundberg N. Continuous recording and control of ventricular fluid pressure in neurosurgical practice. Acta Psychiatr Scand Suppl 1960;36:1-193.
    • (1960) Acta Psychiatr Scand Suppl , vol.36 , pp. 1-193
    • Lundberg, N.1
  • 23
    • 0028314677 scopus 로고
    • Relative risks of ventriculostomies
    • Paramore CG. Relative risks of ventriculostomies. Acta Neurochir Suppl 1994;127:79-84.
    • (1994) Acta Neurochir Suppl , vol.127 , pp. 79-84
    • Paramore, C.G.1
  • 24
    • 58149461545 scopus 로고    scopus 로고
    • Multicenter clinical assessment of the Raumedic Neurovent-P intracranial pressure sensor: A report by the BrainIT group
    • Citerio G, Piper I, Chambers IR, et al. Multicenter clinical assessment of the Raumedic Neurovent-P intracranial pressure sensor: A report by the BrainIT group. Neurosurgery 2008;63:1152-1158.
    • (2008) Neurosurgery , vol.63 , pp. 1152-1158
    • Citerio, G.1    Piper, I.2    Chambers, I.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.