메뉴 건너뛰기




Volumn , Issue , 2011, Pages 4247-4250

A multi-modal approach for hand motion classification using surface EMG and accelerometers

Author keywords

Accelerometer; electromyography; prosthetic hands; prosthetics

Indexed keywords

CLASSIFICATION ACCURACY; ELECTRODE SITES; EMG-ELECTRODES; HAND MOTION; HUMAN MACHINE INTERFACE; IMPROVE-A; INERTIAL SENSOR; MULTI-MODAL APPROACH; MULTIFUNCTION SYSTEMS; MUSCLE FORCE; PROSTHESIS CONTROL; PROSTHETIC HANDS; PROSTHETIC SOCKETS; SPACE LIMITATIONS; SUPPLEMENTARY INFORMATION; SURFACE EMG; THIRD ELECTRODE; UPPER LIMBS;

EID: 84863572543     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2011.6091054     Document Type: Conference Paper
Times cited : (64)

References (17)
  • 1
  • 3
    • 0032757925 scopus 로고    scopus 로고
    • Dimensional change in muscle as a control signal for powered upper limb prostheses: A pilot study
    • Oct
    • L. P. J. Kenney, I. Lisitsa, P. Bowker, G. H. Heath, and D. Howard, "Dimensional Change in Muscle as a Control Signal for Powered Upper Limb Prostheses: a Pilot Study", Med. Eng. Phys., 21(8):589-597, Oct. 1999.
    • (1999) Med. Eng. Phys. , vol.21 , Issue.8 , pp. 589-597
    • Kenney, L.P.J.1    Lisitsa, I.2    Bowker, P.3    Heath, G.H.4    Howard, D.5
  • 7
    • 34247366472 scopus 로고    scopus 로고
    • A comparison of surface and intramuscular myoelectric signal classification
    • May
    • L. J. Hargrove, K. Englehart, B. Hudgins, "A Comparison of Surface and Intramuscular Myoelectric Signal Classification", IEEE Trans. Biomed. Eng., 54(5):847-853, May 2007.
    • (2007) IEEE Trans. Biomed. Eng. , vol.54 , Issue.5 , pp. 847-853
    • Hargrove, L.J.1    Englehart, K.2    Hudgins, B.3
  • 10
    • 33645295504 scopus 로고    scopus 로고
    • Multi-expert automatic speech recognition using acoustic and myoelectric signals
    • Apr
    • A. D. C. Chan, K. Englehart, B. Hudgins, and D. F. Lovely, "Multi-expert automatic speech recognition using acoustic and myoelectric signals", IEEE Trans. Biomed. Eng., 53(4):676-685, Apr. 2006.
    • (2006) IEEE Trans. Biomed. Eng. , vol.53 , Issue.4 , pp. 676-685
    • Chan, A.D.C.1    Englehart, K.2    Hudgins, B.3    Lovely, D.F.4
  • 11
    • 0031222096 scopus 로고    scopus 로고
    • Fusion of audio and video information for multi-modal person authentication
    • Sep
    • B. Duc, E. S. Bigun, J. Bigun, G. Maitre, and S. Fischer, "Fusion of Audio and Video Information for Multi-Modal Person Authentication," Pattern Recognit. Lett., 18(9):835-843, Sep. 1997.
    • (1997) Pattern Recognit. Lett. , vol.18 , Issue.9 , pp. 835-843
    • Duc, B.1    Bigun, E.S.2    Bigun, J.3    Maitre, G.4    Fischer, S.5
  • 14
    • 0042664129 scopus 로고    scopus 로고
    • A robust real-time control scheme for multifunction myoelectric control
    • Jul
    • K. Englehart and B. Hudgins, "A Robust Real-time Control Scheme For Multifunction Myoelectric Control", IEEE Trans. Biomed. Eng., 50(7):848-854, Jul. 2003.
    • (2003) IEEE Trans. Biomed. Eng. , vol.50 , Issue.7 , pp. 848-854
    • Englehart, K.1    Hudgins, B.2
  • 16
    • 67149128290 scopus 로고    scopus 로고
    • Extracting simultaneous and proportional neural control information for multiple-DOF prostheses from the surface electromyographic signal
    • N. Jiang, K. Englehart, and P. A. Parker, "Extracting Simultaneous and Proportional Neural Control Information for Multiple-DOF Prostheses From the Surface Electromyographic Signal", IEEE Trans. Biomed. Eng., 56(4):1070-1080, 2009.
    • (2009) IEEE Trans. Biomed. Eng. , vol.56 , Issue.4 , pp. 1070-1080
    • Jiang, N.1    Englehart, K.2    Parker, P.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.