메뉴 건너뛰기




Volumn 19, Issue 6, 2011, Pages 644-651

Resolving the limb position effect in myoelectric pattern recognition

Author keywords

Accelerometer; electromyography; prosthetic hands; prosthetics

Indexed keywords

CLASSIFICATION ACCURACY; CLASSIFICATION ERRORS; POSITION EFFECT; PROSTHETIC DEVICES; PROSTHETIC HANDS; SEMANTIC GAP; SENSOR FUSION;

EID: 83455259671     PISSN: 15344320     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNSRE.2011.2163529     Document Type: Article
Times cited : (308)

References (25)
  • 1
    • 0042664129 scopus 로고    scopus 로고
    • A robust real-time control scheme for multifunction myoelectric control
    • Jul.
    • K. Englehart and B. Hudgins, "A robust real-time control scheme for multifunction myoelectric control", IEEE Trans. Biomed. Eng., vol. 50, no. 7, pp. 848-854, Jul. 2003.
    • (2003) IEEE Trans. Biomed. Eng. , vol.50 , Issue.7 , pp. 848-854
    • Englehart, K.1    Hudgins, B.2
  • 2
    • 0020332044 scopus 로고
    • EMG pattern analysis and classification for a prosthetic arm
    • Jun.
    • G. N. Saridis and T. P. Gootee, "EMG pattern analysis and classification for a prosthetic arm", IEEE Trans. Biomed. Eng., vol. 29, no. 6, pp. 403-412, Jun. 1982.
    • (1982) IEEE Trans. Biomed. Eng. , vol.29 , Issue.6 , pp. 403-412
    • Saridis, G.N.1    Gootee, T.P.2
  • 3
    • 33750515036 scopus 로고    scopus 로고
    • Myoelectric signal processing for control of powered prosthesis
    • Dec.
    • P. Parker, K. Englehart, and B. Hudgins, "Myoelectric signal processing for control of powered prosthesis", J. Electromyogr. Kinesiol., vol. 16, no. 6, pp. 541-548, Dec. 2006.
    • (2006) J. Electromyogr. Kinesiol. , vol.16 , Issue.6 , pp. 541-548
    • Parker, P.1    Englehart, K.2    Hudgins, B.3
  • 4
    • 27644466209 scopus 로고    scopus 로고
    • A Gaussian mixture model based classification scheme for myoelectric control of powered upper limb prostheses
    • Nov.
    • Y. Huang, K. Englehart, B. Hudgins, and A. D. C. Chan, "A Gaussian mixture model based classification scheme for myoelectric control of powered upper limb prostheses", IEEE Trans. Biomed. Eng., vol. 52, no. 11, pp. 1801-1811, Nov. 2005.
    • (2005) IEEE Trans. Biomed. Eng. , vol.52 , Issue.11 , pp. 1801-1811
    • Huang, Y.1    Englehart, K.2    Hudgins, B.3    Chan, A.D.C.4
  • 5
    • 11244296094 scopus 로고    scopus 로고
    • Continuous myoelectric control for powered prostheses using hidden Markov models
    • Jan.
    • A. D. C. Chan and K. Englehart, "Continuous myoelectric control for powered prostheses using hidden Markov models", IEEE Trans. Biomed. Eng., vol. 52, no. 1, pp. 121-124, Jan. 2005.
    • (2005) IEEE Trans. Biomed. Eng. , vol.52 , Issue.1 , pp. 121-124
    • Chan, A.D.C.1    Englehart, K.2
  • 6
    • 0029347476 scopus 로고
    • The application of cepstral coefficients and maximum likelihood method in EMG pattern recognition
    • Aug.
    • W. J. Kang, J. R. Shiu, C. K. Cheng, J. S. Lai, H. W. Tsao, and T. S. Kuo, "The application of cepstral coefficients and maximum likelihood method in EMG pattern recognition", IEEE Trans. Biomed. Eng., vol. 42, no. 8, pp. 777-785, Aug. 1995.
    • (1995) IEEE Trans. Biomed. Eng. , vol.42 , Issue.8 , pp. 777-785
    • Kang, W.J.1    Shiu, J.R.2    Cheng, C.K.3    Lai, J.S.4    Tsao, H.W.5    Kuo, T.S.6
  • 7
    • 0032128290 scopus 로고    scopus 로고
    • Feature-based classification of myoelectric signals using artificial neural networks
    • Jul.
    • P. J. Gallant, E. L. Morin, and L. E. Peppard, "Feature-based classification of myoelectric signals using artificial neural networks", Med. Bio. Eng. Comp., vol. 36, no. 4, pp. 485-489, Jul. 1998.
    • (1998) Med. Bio. Eng. Comp. , vol.36 , Issue.4 , pp. 485-489
    • Gallant, P.J.1    Morin, E.L.2    Peppard, L.E.3
  • 8
    • 70349306171 scopus 로고    scopus 로고
    • Functional outcomes in the WHO-ICF model: Establishment of the upper limb prosthetic outcome measures group
    • W. Hill, Ø. Stavdahl, L. N. Hermansson, P. Kyberd, S. Swanson, and S. Hubbard, "Functional outcomes in the WHO-ICF model: Establishment of the upper limb prosthetic outcome measures group", J. Prosthet. Orthot., vol. 21, pp. 115-119, 2009.
    • (2009) J. Prosthet. Orthot. , vol.21 , pp. 115-119
    • Hill, W.1    Stavdahl, Ø.2    Hermansson, L.N.3    Kyberd, P.4    Swanson, S.5    Hubbard, S.6
  • 10
    • 41149111431 scopus 로고    scopus 로고
    • A training strategy to reduce classification degradation due to electrode displacements in pattern recognition based myoelectric control
    • L. Hargrove, K. Englehart, and B. Hudgins, "A training strategy to reduce classification degradation due to electrode displacements in pattern recognition based myoelectric control", Biomed. Signal Process. Contr., vol. 3, no. 2, pp. 175-180, 2008.
    • (2008) Biomed. Signal Process. Contr. , vol.3 , Issue.2 , pp. 175-180
    • Hargrove, L.1    Englehart, K.2    Hudgins, B.3
  • 11
    • 0022617107 scopus 로고
    • Relative activation of two human elbow flexors under isometric conditions: A cautionary note concerning flexor equivalence
    • J. D. Howard, J. D. Hoit, R. M. Enoka, and Z. Hasan, "Relative activation of two human elbow flexors under isometric conditions: A cautionary note concerning flexor equivalence", Exp. Brain Res., vol. 62, no. 1, pp. 199-202, 1986.
    • (1986) Exp. Brain Res. , vol.62 , Issue.1 , pp. 199-202
    • Howard, J.D.1    Hoit, J.D.2    Enoka, R.M.3    Hasan, Z.4
  • 12
    • 0027451761 scopus 로고
    • Muscle synergies and isometric torque production: Influence of supination and pronation level on elbow flexion
    • J. C. Jamison and G. E. Caldwell, "Muscle synergies and isometric torque production: Influence of supination and pronation level on elbow flexion", J. Neurophys., vol. 70, no. 3, pp. 947-960, 1993.
    • (1993) J. Neurophys. , vol.70 , Issue.3 , pp. 947-960
    • Jamison, J.C.1    Caldwell, G.E.2
  • 15
    • 78650929654 scopus 로고    scopus 로고
    • Automatic recognition of sign language subwords based on portable accelerometer and EMG sensors
    • Beijing, China, Nov.
    • Y. Li, X. Chen, J. Tian, X. Zhang, K. Wang, and J. Yang, "Automatic recognition of sign language subwords based on portable accelerometer and EMG sensors", in Proc. ICMI-MLMI'10, Beijing, China, Nov. 2010.
    • (2010) Proc. ICMI-MLMI'10
    • Li, Y.1    Chen, X.2    Tian, J.3    Zhang, X.4    Wang, K.5    Yang, J.6
  • 18
    • 84943709252 scopus 로고
    • Use of ranks in one-criterion variance analysis
    • Dec.
    • W. Kruskal and W. A. Wallis, "Use of ranks in one-criterion variance analysis", J. Amer. Stat. Assoc., vol. 47, no. 260, pp. 583-621, Dec. 1952.
    • (1952) J. Amer. Stat. Assoc. , vol.47 , Issue.260 , pp. 583-621
    • Kruskal, W.1    Wallis, W.A.2
  • 20
    • 83455233304 scopus 로고    scopus 로고
    • 7th Int. ed. Boston, MA: Wadsworth
    • B. Rosner, Fundamentals of Biostatistics, 7th (Int.) ed. Boston, MA: Wadsworth, 2011, pp. 555-561.
    • (2011) Fundamentals of Biostatistics , pp. 555-561
    • Rosner, B.1
  • 22
    • 57649232883 scopus 로고    scopus 로고
    • A real-time pattern recognition based myoelectric control usability study implemented in a virtual environment
    • Lyon
    • L. Hargrove, Y. Losier, B. Lock, K. Englehart, and B. Hudgins, "A real-time pattern recognition based myoelectric control usability study implemented in a virtual environment", in Eng. Med. Biol., Lyon, 2007, pp. 4842-4845.
    • (2007) Eng. Med. Biol. , pp. 4842-4845
    • Hargrove, L.1    Losier, Y.2    Lock, B.3    Englehart, K.4    Hudgins, B.5
  • 23
    • 60249084509 scopus 로고    scopus 로고
    • Targeted muscle reinnervation for real-time myoelectric control of multifunction artificial arms
    • T. Kuiken, G. Li, B. Lock, R. Lipschutz, L. Miller, K. Stubblefield, and K. Englehart, "Targeted muscle reinnervation for real-time myoelectric control of multifunction artificial arms", J. Amer. Med. Assoc., vol. 301, no. 6, pp. 619-628, 2009.
    • (2009) J. Amer. Med. Assoc. , vol.301 , Issue.6 , pp. 619-628
    • Kuiken, T.1    Li, G.2    Lock, B.3    Lipschutz, R.4    Miller, L.5    Stubblefield, K.6    Englehart, K.7
  • 24
    • 67149128290 scopus 로고    scopus 로고
    • Extracting simultaneous and proportional neural control information for multiple-DOF prostheses from the surface electromyographic signal
    • Apr.
    • N. Jiang, K. Englehart, and P. A. Parker, "Extracting simultaneous and proportional neural control information for multiple-DOF prostheses from the surface electromyographic signal", IEEE Trans. Biomed. Eng., vol. 56, no. 4, pp. 1070-1080, Apr. 2009.
    • (2009) IEEE Trans. Biomed. Eng. , vol.56 , Issue.4 , pp. 1070-1080
    • Jiang, N.1    Englehart, K.2    Parker, P.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.