메뉴 건너뛰기




Volumn , Issue , 2011, Pages 4301-4304

Haemodynamic modeling of the cardiovascular system using mock circulation loops to test cardiovascular devices

Author keywords

[No Author keywords available]

Indexed keywords

ANATOMICAL VARIATIONS; ANIMAL TESTING; AUTOREGULATIONS; CARDIAC FUNCTIONS; CARDIAC OUTPUT; CARDIOVASCULAR DEVICES; CARDIOVASCULAR STENTS; COMPREHENSIVE TESTING; COUNTERPULSATION; HAEMODYNAMICS; HEART FAILURE; HEART RATES; HEART TRANSPLANTATION; HUMAN CARDIOVASCULAR SYSTEMS; IN-VITRO; IN-VIVO; LOOP PERFORMANCE; MOCK CIRCULATION; MOCK CIRCULATION SYSTEM; NON-INVASIVE; PHYSIOLOGICAL CONTROL; PHYSIOLOGICAL RESPONSE; PROOF OF CONCEPT; PROOF OF PRINCIPLES; RAPID TRANSITIONS; SEPTAL DEFECT; SKELETAL MUSCLE; STEADY STATE; TESTING APPARATUS; VARIABLE PARAMETERS; VENTRICULAR ASSIST DEVICE;

EID: 84863568668     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2011.6091068     Document Type: Conference Paper
Times cited : (13)

References (11)
  • 3
    • 0017334719 scopus 로고
    • An aortic-left ventricular pulse duplicator used in testing prosthetic aortic heart valves
    • Cornhill, J., An aortic-left ventricular pulse duplicator used in testing prosthetic aortic heart valves. The Journal of Thoracic and Cardiovascular Surgery, 1977. 73(4): p. 550-558.
    • (1977) The Journal of Thoracic and Cardiovascular Surgery , vol.73 , Issue.4 , pp. 550-558
    • Cornhill, J.1
  • 4
    • 0348230939 scopus 로고    scopus 로고
    • Characterization of an adult mock circulation for testing cardiac support devices
    • Pantalos, G., S. Koenig, K. Gillars, G. Giridharan, and D. Ewert, Characterization of an adult mock circulation for testing cardiac support devices. ASAIO, 2004. 50(1): p. 37-46.
    • (2004) ASAIO , vol.50 , Issue.1 , pp. 37-46
    • Pantalos, G.1    Koenig, S.2    Gillars, K.3    Giridharan, G.4    Ewert, D.5
  • 6
    • 79955000756 scopus 로고    scopus 로고
    • A compact mock circulation loop for the in vitro testing of cardiovascular devices
    • Timms, D.L., S.D. Gregory, N.A. Greatrex, et al., A Compact Mock Circulation Loop for the In Vitro Testing of Cardiovascular Devices. Artif Organs, 2011. 35(4): p. 384-391.
    • (2011) Artif Organs , vol.35 , Issue.4 , pp. 384-391
    • Timms, D.L.1    Gregory, S.D.2    Greatrex, N.A.3
  • 7
    • 67651154192 scopus 로고    scopus 로고
    • A naturally shaped silicone ventricle evaluated in a mock circulation loop - A preliminary study
    • Gregory, S., D. Timms, G. Tansley, and M. Pearcy, A Naturally Shaped Silicone Ventricle Evaluated in a Mock Circulation Loop - A Preliminary Study. J Med Eng Technol, 2008. 33(3): p. 185-191.
    • (2008) J Med Eng Technol , vol.33 , Issue.3 , pp. 185-191
    • Gregory, S.1    Timms, D.2    Tansley, G.3    Pearcy, M.4
  • 8
    • 77958567429 scopus 로고    scopus 로고
    • Flow analysis of ventricular assist device inflow and outflow cannula positioning using a naturally shaped ventricle and aortic branch
    • Laumen, M., T. Kaufmann, D. Timms, P. Schlanstein, S. Jansen, S. Gregory, K.C. Wong, T. Schmitz-Rode, and U. Steinseifer, Flow Analysis of Ventricular Assist Device Inflow and Outflow Cannula Positioning Using a Naturally Shaped Ventricle and Aortic Branch. Artif Organs, 2010. 34(10): p. 798-806.
    • (2010) Artif Organs , vol.34 , Issue.10 , pp. 798-806
    • Laumen, M.1    Kaufmann, T.2    Timms, D.3    Schlanstein, P.4    Jansen, S.5    Gregory, S.6    Wong, K.C.7    Schmitz-Rode, T.8    Steinseifer, U.9
  • 9
    • 84864613324 scopus 로고    scopus 로고
    • Replication of the frank-starling response in a mock circulation loop
    • Boston
    • Gregory, S., M. Stevens, D. Timms, and J. Fraser, Replication of the Frank-Starling Response in a Mock Circulation Loop, in IEEE EMBS. 2011: Boston.
    • (2011) IEEE EMBS
    • Gregory, S.1    Stevens, M.2    Timms, D.3    Fraser, J.4
  • 10
    • 0029967850 scopus 로고    scopus 로고
    • Effects of hypovolemia and posture on responses to the Valsalva maneuver
    • Luster, E., N. Baumgartner, W. Adams, and V. Convertino, Effects of hypovolemia and posture on responses to the Valsalva maneuver. Aviat Space Environ Med., 1996. 67(4): p. 308-313.
    • (1996) Aviat Space Environ Med. , vol.67 , Issue.4 , pp. 308-313
    • Luster, E.1    Baumgartner, N.2    Adams, W.3    Convertino, V.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.