Volumn 39, Issue 6, 2012, Pages 3167-3180

Quantification of scattered radiation in projection mammography: Four practical methods compared

Author keywords

beam stop; edge spread function (ESF); mammography; modulation transfer function (MTF); Monte Carlo; scatter; scatter to primary ratio (SPR)

Indexed keywords

ERRORS; ESTERS; FREQUENCY ESTIMATION; GEOMETRY; MAMMOGRAPHY; MODULATION; OPTICAL TRANSFER FUNCTION; SCATTERING;

EID: 84863509382     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.4711754     Document Type: Article
Times cited : (37)

References (44)
  • 1
    • 0026127196 scopus 로고
    • Contrast and scatter in x-ray imaging
    • G. T. Barnes, Contrast and scatter in x-ray imaging., Radiographics 11, 307-323 (1991).
    • (1991) Radiographics , vol.11 , pp. 307-323
    • Barnes, G.T.1
  • 2
    • 0026689155 scopus 로고
    • Grids or air gaps for scatter reduction in digital radiography: A model calculation
    • 10.1118/1.596836
    • U. Neitzel, Grids or air gaps for scatter reduction in digital radiography: A model calculation., Med. Phys. 19, 475-481 (1992). 10.1118/1.596836
    • (1992) Med. Phys. , vol.19 , pp. 475-481
    • Neitzel, U.1
  • 3
    • 0019941033 scopus 로고
    • Investigation of the performance of antiscatter grids: Monte Carlo simulation studies
    • 10.1088/0031-9155/27/6/002
    • H. P. Chan and K. Doi, Investigation of the performance of antiscatter grids: Monte Carlo simulation studies., Phys. Med. Biol. 27, 785-803 (1982). 10.1088/0031-9155/27/6/002
    • (1982) Phys. Med. Biol. , vol.27 , pp. 785-803
    • Chan, H.P.1    Doi, K.2
  • 4
    • 0028040853 scopus 로고
    • A Monte Carlo study of grid performance in diagnostic radiology: Task-dependent optimization for digital imaging
    • 10.1088/0031-9155/39/10/010
    • M. Sandborg, D. R. Dance, G. A. Carlsson, J. Persliden, and M. J. Tapiovaara, A Monte Carlo study of grid performance in diagnostic radiology: Task-dependent optimization for digital imaging., Phys. Med. Biol. 39, 1659-1676 (1994). 10.1088/0031-9155/39/10/010
    • (1994) Phys. Med. Biol. , vol.39 , pp. 1659-1676
    • Sandborg, M.1    Dance, D.R.2    Carlsson, G.A.3    Persliden, J.4    Tapiovaara, M.J.5
  • 5
    • 61549101239 scopus 로고    scopus 로고
    • The effect of scatter and glare on image quality in contrast-enhanced breast imaging using an a-Si/CsI(Tl) full-field flat panel detector
    • 10.1118/1.3077922
    • A. K. Carton, R. Acciavatti, J. Kuo, and A. D. A. Maidment, The effect of scatter and glare on image quality in contrast-enhanced breast imaging using an a-Si/CsI(Tl) full-field flat panel detector., Med. Phys. 36, 920-928 (2009). 10.1118/1.3077922
    • (2009) Med. Phys. , vol.36 , pp. 920-928
    • Carton, A.K.1    Acciavatti, R.2    Kuo, J.3    Maidment, A.D.A.4
  • 6
    • 0041386608 scopus 로고    scopus 로고
    • Development and validation of a simulation procedure to study the visibility of micro calcifications in digital mammograms
    • 10.1118/1.1591193
    • A. K. Carton, H. Bosmans, C. Van Ongeval, G. Souverijns, F. Rogge, A. Van Steen, and G. Marchal, Development and validation of a simulation procedure to study the visibility of micro calcifications in digital mammograms., Med. Phys. 30, 2234-2240 (2003). 10.1118/1.1591193
    • (2003) Med. Phys. , vol.30 , pp. 2234-2240
    • Carton, A.K.1    Bosmans, H.2    Van Ongeval, C.3    Souverijns, G.4    Rogge, F.5    Van Steen, A.6    Marchal, G.7
  • 7
    • 70349659698 scopus 로고    scopus 로고
    • Evaluation of scatter effects on image quality for breast tomosynthesis
    • 10.1118/1.3215926
    • G. Wu, J. G. Mainprize, J. M. Boone, and M. J. Yaffe, Evaluation of scatter effects on image quality for breast tomosynthesis., Med. Phys. 36, 4425-4432 (2009). 10.1118/1.3215926
    • (2009) Med. Phys. , vol.36 , pp. 4425-4432
    • Wu, G.1    Mainprize, J.G.2    Boone, J.M.3    Yaffe, M.J.4
  • 9
    • 0017877595 scopus 로고
    • The intensity of scattered radiation in mammography
    • G. T. Barnes and I. A. Brezovich, The intensity of scattered radiation in mammography., Radiology 126, 243-247 (1978).
    • (1978) Radiology , vol.126 , pp. 243-247
    • Barnes, G.T.1    Brezovich, I.A.2
  • 10
    • 0019373877 scopus 로고
    • Scattered radiation in chest radiography
    • 10.1118/1.595027
    • L. T. Niklason, J. A. Sorenson, and J. A. Nelson, Scattered radiation in chest radiography., Med. Phys. 8, 677-681 (1981). 10.1118/1.595027
    • (1981) Med. Phys. , vol.8 , pp. 677-681
    • Niklason, L.T.1    Sorenson, J.A.2    Nelson, J.A.3
  • 11
    • 0025765012 scopus 로고
    • Quantitative scatter measurement in digital radiography using a photostimulable phosphor imaging system
    • 10.1118/1.596687
    • C. E. Floyd, J. Y. Lo, H. G. Chotas, and C. E. Ravin, Quantitative scatter measurement in digital radiography using a photostimulable phosphor imaging system., Med. Phys. 18, 408-413 (1991). 10.1118/1.596687
    • (1991) Med. Phys. , vol.18 , pp. 408-413
    • Floyd, C.E.1    Lo, J.Y.2    Chotas, H.G.3    Ravin, C.E.4
  • 12
    • 0033735247 scopus 로고    scopus 로고
    • Scatter/primary in mammography: Comprehensive results
    • 10.1118/1.1312812
    • J. M. Boone, K. K. Lindfors, V. N. Cooper, and J. A. Seibert, Scatter/primary in mammography: Comprehensive results., Med. Phys. 27, 2408-2416 (2000). 10.1118/1.1312812
    • (2000) Med. Phys. , vol.27 , pp. 2408-2416
    • Boone, J.M.1    Lindfors, K.K.2    Cooper, V.N.3    Seibert, J.A.4
  • 14
    • 0021224747 scopus 로고
    • The computation of scatter in mammography by Monte Carlo methods
    • 10.1088/0031-9155/29/3/003
    • D. R. Dance and G. J. Day, The computation of scatter in mammography by Monte Carlo methods., Phys. Med. Biol. 29, 237-247 (1984). 10.1088/0031-9155/29/ 3/003
    • (1984) Phys. Med. Biol. , vol.29 , pp. 237-247
    • Dance, D.R.1    Day, G.J.2
  • 15
    • 0020680912 scopus 로고
    • The validity of Monte Carlo simulation in studies of scattered radiation in diagnostic radiology
    • 10.1088/0031-9155/28/2/001
    • H. P. Chan and K. Doi, The validity of Monte Carlo simulation in studies of scattered radiation in diagnostic radiology., Phys. Med. Biol. 28, 109-129 (1983). 10.1088/0031-9155/28/2/001
    • (1983) Phys. Med. Biol. , vol.28 , pp. 109-129
    • Chan, H.P.1    Doi, K.2
  • 16
    • 0033860358 scopus 로고    scopus 로고
    • Scatter/primary in mammography: Monte Carlo validation
    • 10.1118/1.1287052
    • J. M. Boone and V. N. Cooper, Scatter/primary in mammography: Monte Carlo validation., Med. Phys. 27, 1818-1831 (2000). 10.1118/1.1287052
    • (2000) Med. Phys. , vol.27 , pp. 1818-1831
    • Boone, J.M.1    Cooper, V.N.2
  • 18
    • 0023736317 scopus 로고
    • Monte Carlo simulation of the scattered radiation distribution in diagnostic radiology
    • 10.1118/1.596185
    • J. M. Boone and J. A. Seibert, Monte Carlo simulation of the scattered radiation distribution in diagnostic radiology., Med. Phys. 15, 713-720 (1988). 10.1118/1.596185
    • (1988) Med. Phys. , vol.15 , pp. 713-720
    • Boone, J.M.1    Seibert, J.A.2
  • 19
    • 33745422469 scopus 로고    scopus 로고
    • A Monte Carlo investigation on the impact of scattered radiation on mammographic resolution and noise
    • 10.1117/12.653199
    • J. R. S. Saunders and E. Samei, A Monte Carlo investigation on the impact of scattered radiation on mammographic resolution and noise., Proc. SPIE 6142, 61423A (2006). 10.1117/12.653199
    • (2006) Proc. SPIE , vol.6142
    • Saunders, J.R.S.1    Samei, E.2
  • 20
    • 14644403625 scopus 로고    scopus 로고
    • Generalizing the MTF and DQE to include x-ray scatter and focal spot unsharpness: Application to a new microangiographic system
    • 10.1118/1.1844151
    • I. Kyprianou, S. Rudin, D. Bednarek, and K. Hoffmann, Generalizing the MTF and DQE to include x-ray scatter and focal spot unsharpness: Application to a new microangiographic system., Med. Phys. 32, 613-626 (2005). 10.1118/1.1844151
    • (2005) Med. Phys. , vol.32 , pp. 613-626
    • Kyprianou, I.1    Rudin, S.2    Bednarek, D.3    Hoffmann, K.4
  • 21
    • 0034111936 scopus 로고    scopus 로고
    • An edge spread technique for measurement of the scatter-to-primary ratio in mammography
    • 10.1118/1.598950
    • V. N. Cooper III, J. M. Boone, J. A. Seibert, and C. J. Pellot-Barakat, An edge spread technique for measurement of the scatter-to-primary ratio in mammography., Med. Phys. 27, 845-853 (2000). 10.1118/1.598950
    • (2000) Med. Phys. , vol.27 , pp. 845-853
    • Cooper Iii, V.N.1    Boone, J.M.2    Seibert, J.A.3    Pellot-Barakat, C.J.4
  • 22
    • 33645505957 scopus 로고    scopus 로고
    • Effect of scatter and an antiscatter grid on the performance of a slot-scanning digital mammography system
    • 10.1118/1.2184445
    • S. Z. Shen, A. K. Bloomquist, G. E. Mawdsley, M. J. Yaffe, and I. Elbakri, Effect of scatter and an antiscatter grid on the performance of a slot-scanning digital mammography system., Med. Phys. 33, 1108-1115 (2006). 10.1118/1.2184445
    • (2006) Med. Phys. , vol.33 , pp. 1108-1115
    • Shen, S.Z.1    Bloomquist, A.K.2    Mawdsley, G.E.3    Yaffe, M.J.4    Elbakri, I.5
  • 26
    • 0038377458 scopus 로고    scopus 로고
    • GEANT4: A simulation toolkit
    • 10.1016/S0168-9002(03)01368-8
    • S. Agostinelli, GEANT4: A simulation toolkit., Nucl. Instrum. Methods 506, 250-303 (2003). 10.1016/S0168-9002(03)01368-8
    • (2003) Nucl. Instrum. Methods , vol.506 , pp. 250-303
    • Agostinelli, S.1
  • 28
    • 65249160230 scopus 로고    scopus 로고
    • Overview of physical interaction models for photon and electron transport used in Monte Carlo codes
    • 10.1088/0026-1394/46/2/S08
    • F. Salvat and J. M. Fernández-Varea, Overview of physical interaction models for photon and electron transport used in Monte Carlo codes., Metrologia 46, S112-S138 (2009). 10.1088/0026-1394/46/2/S08
    • (2009) Metrologia , vol.46
    • Salvat, F.1    Fernández-Varea, J.M.2
  • 29
    • 0034451289 scopus 로고    scopus 로고
    • Comparative evaluation of photon cross-section libraries for materials of interest in PET Monte Carlo simulations
    • 10.1109/23.901179
    • H. Zaidi, Comparative evaluation of photon cross-section libraries for materials of interest in PET Monte Carlo simulations., IEEE Trans. Nucl. Sci. 47, 2722-2735 (2000). 10.1109/23.901179
    • (2000) IEEE Trans. Nucl. Sci. , vol.47 , pp. 2722-2735
    • Zaidi, H.1
  • 30
    • 1142287542 scopus 로고    scopus 로고
    • Benchmark of PENELOPE code for low-energy photon transport: Dose comparisons with MCNP4 and EGS4
    • 10.1088/0031-9155/49/3/003
    • S. J. Ye, I. A. Brezovich, P. Pareek, and S. A. Naqvi, Benchmark of PENELOPE code for low-energy photon transport: Dose comparisons with MCNP4 and EGS4., Phys. Med. Biol. 49, 387-397 (2004). 10.1088/0031-9155/49/3/003
    • (2004) Phys. Med. Biol. , vol.49 , pp. 387-397
    • Ye, S.J.1    Brezovich, I.A.2    Pareek, P.3    Naqvi, S.A.4
  • 31
    • 77952335394 scopus 로고    scopus 로고
    • Simulation of image detectors in radiology for determination of scatter-to-primary ratios using Monte Carlo radiation transport code MCNP/MCNPX
    • 10.1118/1.3377773
    • K. Smans, J. Zoetelief, B. Verbrugge, W. Haeck, L. Struelens, F. Vanhavere, and H. Bosmans, Simulation of image detectors in radiology for determination of scatter-to-primary ratios using Monte Carlo radiation transport code MCNP/MCNPX., Med. Phys. 37, 2082-2091 (2010). 10.1118/1.3377773
    • (2010) Med. Phys. , vol.37 , pp. 2082-2091
    • Smans, K.1    Zoetelief, J.2    Verbrugge, B.3    Haeck, W.4    Struelens, L.5    Vanhavere, F.6    Bosmans, H.7
  • 32
    • 0031841920 scopus 로고    scopus 로고
    • Scattered radiation in scanning slot mammography
    • 10.1118/1.598433
    • Z. Jing, W. Huda, and J. K. Walker, Scattered radiation in scanning slot mammography., Med. Phys. 25, 1111-1117 (1998). 10.1118/1.598433
    • (1998) Med. Phys. , vol.25 , pp. 1111-1117
    • Jing, Z.1    Huda, W.2    Walker, J.K.3
  • 33
    • 0034068554 scopus 로고    scopus 로고
    • Digital mammography image simulation using Monte Carlo
    • 10.1118/1.598896
    • D. E. Peplow and K. Verghese, Digital mammography image simulation using Monte Carlo., Med. Phys. 27, 568-579 (2000). 10.1118/1.598896
    • (2000) Med. Phys. , vol.27 , pp. 568-579
    • Peplow, D.E.1    Verghese, K.2
  • 34
    • 0031950889 scopus 로고    scopus 로고
    • A method for measuring the presampled MTF of digital radiographic systems using an edge test device
    • 10.1118/1.598165
    • E. Samei, M. J. Flynn, and D. A. Reimann, A method for measuring the presampled MTF of digital radiographic systems using an edge test device., Med. Phys. 25, 102-113 (1998). 10.1118/1.598165
    • (1998) Med. Phys. , vol.25 , pp. 102-113
    • Samei, E.1    Flynn, M.J.2    Reimann, D.A.3
  • 35
    • 33646485572 scopus 로고    scopus 로고
    • A comparison between objective and subjective image quality measurements for a full field digital mammography system
    • 10.1088/0031-9155/51/10/006
    • N. W. Marshall, A comparison between objective and subjective image quality measurements for a full field digital mammography system., Phys. Med. Biol. 51, 2441-2463 (2006). 10.1088/0031-9155/51/10/006
    • (2006) Phys. Med. Biol. , vol.51 , pp. 2441-2463
    • Marshall, N.W.1
  • 37
    • 33645525594 scopus 로고    scopus 로고
    • Scatter rejection in multislit digital mammography
    • 10.1118/1.2179122
    • M. Åslund, B. Cederström, M. Lundqvist, and M. Danielsson, Scatter rejection in multislit digital mammography., Med. Phys. 33, 933-940 (2006). 10.1118/1.2179122
    • (2006) Med. Phys. , vol.33 , pp. 933-940
    • Åslund, M.1    Cederström, B.2    Lundqvist, M.3    Danielsson, M.4
  • 38
    • 79953671749 scopus 로고    scopus 로고
    • Oblique incidence effects in direct x-ray detectors: A first-order approximation using a physics-based analytical model
    • 10.1118/1.3567497
    • A. Badano, M. Freed, and Y. Fang, Oblique incidence effects in direct x-ray detectors: A first-order approximation using a physics-based analytical model., Med. Phys. 38, 2095-2108 (2011). 10.1118/1.3567497
    • (2011) Med. Phys. , vol.38 , pp. 2095-2108
    • Badano, A.1    Freed, M.2    Fang, Y.3
  • 39
    • 0028941060 scopus 로고
    • X-ray imaging using amorphous selenium: Inherent spatial resolution
    • 10.1118/1.597471
    • W. Que and J. A. Rowlands, X-ray imaging using amorphous selenium: Inherent spatial resolution., Med. Phys. 22, 365-374 (1995). 10.1118/1.597471
    • (1995) Med. Phys. , vol.22 , pp. 365-374
    • Que, W.1    Rowlands, J.A.2
  • 40
    • 33748303079 scopus 로고    scopus 로고
    • Resolution at oblique incidence angles of a flat panel imager for breast tomosynthesis
    • 10.1118/1.2241994
    • J. G. Mainprize, A. K. Bloomquist, M. P. Kempston, and M. J. Yaffe, Resolution at oblique incidence angles of a flat panel imager for breast tomosynthesis., Med. Phys. 33, 3159-3164 (2006). 10.1118/1.2241994
    • (2006) Med. Phys. , vol.33 , pp. 3159-3164
    • Mainprize, J.G.1    Bloomquist, A.K.2    Kempston, M.P.3    Yaffe, M.J.4
  • 41
    • 33646438839 scopus 로고    scopus 로고
    • Intercomparison of methods for image quality characterization. I. Modulation transfer function
    • 10.1118/1.2188816
    • E. Samei, N. T. Ranger, J. T. Dobbins, and Y. Chen, Intercomparison of methods for image quality characterization. I. Modulation transfer function., Med. Phys. 33, 1454-1465 (2006). 10.1118/1.2188816
    • (2006) Med. Phys. , vol.33 , pp. 1454-1465
    • Samei, E.1    Ranger, N.T.2    Dobbins, J.T.3    Chen, Y.4
  • 42
    • 33644685403 scopus 로고    scopus 로고
    • MANTIS: Combined x-ray, electron and optical Monte Carlo simulations of indirect radiation imaging systems
    • 10.1088/0031-9155/51/6/013
    • A. Badano and J. Sempau, MANTIS: Combined x-ray, electron and optical Monte Carlo simulations of indirect radiation imaging systems., Phys. Med. Biol. 51, 1545-1561 (2006). 10.1088/0031-9155/51/6/013
    • (2006) Phys. Med. Biol. , vol.51 , pp. 1545-1561
    • Badano, A.1    Sempau, J.2
  • 43
    • 79953671061 scopus 로고    scopus 로고
    • Monte Carlo simulation of amorphous selenium imaging detectors
    • 10.1117/12.844983
    • Y. Fang, A. Badal, N. Allec, K. S. Karim, and A. Badano, Monte Carlo simulation of amorphous selenium imaging detectors., Proc. SPIE 7622, 762214 (2010). 10.1117/12.844983
    • (2010) Proc. SPIE , vol.7622 , pp. 762214
    • Fang, Y.1    Badal, A.2    Allec, N.3    Karim, K.S.4    Badano, A.5
  • 44
    • 84855472614 scopus 로고    scopus 로고
    • Spatiotemporal Monte Carlo transport methods in x-ray semiconductor detectors: Application to pulse-height spectroscopy in a-Se
    • 10.1118/1.3669486
    • Y. Fang, A. Badal, N. Allec, K. S. Karim, and A. Badano, Spatiotemporal Monte Carlo transport methods in x-ray semiconductor detectors: Application to pulse-height spectroscopy in a-Se., Med. Phys. 39, 308-319 (2012). 10.1118/1.3669486
    • (2012) Med. Phys. , vol.39 , pp. 308-319
    • Fang, Y.1    Badal, A.2    Allec, N.3    Karim, K.S.4    Badano, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.