-
1
-
-
33745398327
-
Anisotropic imaging performance in indirect x-ray imaging detectors
-
A. Badano, I. S. Kyprianou, and J. Sempau, "Anisotropic imaging performance in indirect x-ray imaging detectors," Med. Phys. 33(8), 2698-2713 (2006).
-
(2006)
Med. Phys.
, vol.33
, Issue.8
, pp. 2698-2713
-
-
Badano, A.1
Kyprianou, I.S.2
Sempau, J.3
-
2
-
-
35648983440
-
Anisotropic imaging performance in breast tomosynthesis
-
A. Badano, I. S. Kyprianou, R. J. Jennings, and J. Sempau, "Anisotropic imaging performance in breast tomosynthesis," Med. Phys. 34(11), 4076-4091 (2007).
-
(2007)
Med. Phys.
, vol.34
, Issue.11
, pp. 4076-4091
-
-
Badano, A.1
Kyprianou, I.S.2
Jennings, R.J.3
Sempau, J.4
-
3
-
-
33748303079
-
Resolution at oblique incidence angles of a flat panel imager for breast tomosynthesis
-
J. G. Mainprize, A. K. Bloomquist, M. P. Kempston, and M. J. Yaffe, "Resolution at oblique incidence angles of a flat panel imager for breast tomosynthesis," Med. Phys. 33(9), 3159-3164 (2006).
-
(2006)
Med. Phys.
, vol.33
, Issue.9
, pp. 3159-3164
-
-
Mainprize, J.G.1
Bloomquist, A.K.2
Kempston, M.P.3
Yaffe, M.J.4
-
4
-
-
0028941060
-
X-ray imaging using amorphous selenium: Inherent spatial resolution
-
W. Que and J. A. Rowlands, "X-ray imaging using amorphous selenium: Inherent spatial resolution," Med. Phys. 22(4), 365-374 (1995).
-
(1995)
Med. Phys.
, vol.22
, Issue.4
, pp. 365-374
-
-
Que, W.1
Rowlands, J.A.2
-
5
-
-
65549148766
-
Experimental validation of Monte Carlo (MANTIS) simulated x-ray response of columnar CsI scintillator screens
-
M. Freed, S. Miller, K. Tang, and A. Badano, "Experimental validation of Monte Carlo (MANTIS) simulated x-ray response of columnar CsI scintillator screens," Med. Phys. 36(11), 4944-4956 (2009).
-
(2009)
Med. Phys.
, vol.36
, Issue.11
, pp. 4944-4956
-
-
Freed, M.1
Miller, S.2
Tang, K.3
Badano, A.4
-
6
-
-
65549096469
-
Effect of oblique x-ray incidence in flat-panel computed tomography of the breast
-
A. Badano, I. S. Kyprianou, M. Freed, R. J. Jennings, and J. Sempau, "Effect of oblique x-ray incidence in flat-panel computed tomography of the breast," IEEE Trans. Med. Imaging 28(5), 696-702 (2009).
-
(2009)
IEEE Trans. Med. Imaging
, vol.28
, Issue.5
, pp. 696-702
-
-
Badano, A.1
Kyprianou, I.S.2
Freed, M.3
Jennings, R.J.4
Sempau, J.5
-
7
-
-
33644685403
-
MANTIS: Combined x-ray, electron and optical Monte Carlo simulations of indirect radiation imaging systems
-
A. Badano and J. Sempau, "MANTIS: Combined x-ray, electron and optical Monte Carlo simulations of indirect radiation imaging systems," Phys. Med. Biol. 51(6), 1545-1561 (2006).
-
(2006)
Phys. Med. Biol.
, vol.51
, Issue.6
, pp. 1545-1561
-
-
Badano, A.1
Sempau, J.2
-
8
-
-
79953671061
-
Monte Carlo simulation of amorphous selenium imaging detectors
-
Y. Fang, A. Badal, N. Allec, K. Karim, and A. Badano, "Monte Carlo simulation of amorphous selenium imaging detectors," Proc. SPIE 7622, 762214-1-762214-9 (2010).
-
(2010)
Proc. SPIE
, vol.7622
, pp. 7622141-7622149
-
-
Fang, Y.1
Badal, A.2
Allec, N.3
Karim, K.4
Badano, A.5
-
9
-
-
77953506834
-
A fast, angle-dependent, analytical model of CsI detector response for optimization of 3D x-ray breast imaging systems
-
M. Freed, S. Park, and A. Badano, "A fast, angle-dependent, analytical model of CsI detector response for optimization of 3D x-ray breast imaging systems," Med. Phys. 37(6), 2593-2605 (2010).
-
(2010)
Med. Phys.
, vol.37
, Issue.6
, pp. 2593-2605
-
-
Freed, M.1
Park, S.2
Badano, A.3
-
10
-
-
0003797116
-
-
OECD Issy-les-Moulineaux, France, available in PFD format at
-
F. Salvat, J. M. Fernández-Varea, and J. Sempau, PENELOPE: A code system for Monte Carlo simulation of electron and photon transport, OECD Nuclear Energy Agency, Issy-les-Moulineaux, France, 2003, available in PFD format at http://www.nea.fr.
-
(2003)
PENELOPE: A Code System for Monte Carlo Simulation of Electron and Photon Transport
-
-
Salvat, F.1
Fernández-Varea, J.M.2
Sempau, J.3
|