Volumn 38, Issue 4, 2011, Pages 2095-2098

Oblique incidence effects in direct x-ray detectors: A first-order approximation using a physics-based analytical model

Author keywords

detector response; direct detectors; indirect detector oblique incidence

Indexed keywords

ANALYTICAL MODELS; CESIUM IODIDE; MAMMOGRAPHY; MEDICAL IMAGING; SEMICONDUCTOR DETECTORS; X RAYS;

EID: 79953671749     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3567497     Document Type: Article
Times cited : (24)

References (11)
  • 1
    • 33745398327 scopus 로고    scopus 로고
    • Anisotropic imaging performance in indirect x-ray imaging detectors
    • A. Badano, I. S. Kyprianou, and J. Sempau, "Anisotropic imaging performance in indirect x-ray imaging detectors," Med. Phys. 33(8), 2698-2713 (2006).
    • (2006) Med. Phys. , vol.33 , Issue.8 , pp. 2698-2713
    • Badano, A.1    Kyprianou, I.S.2    Sempau, J.3
  • 2
    • 35648983440 scopus 로고    scopus 로고
    • Anisotropic imaging performance in breast tomosynthesis
    • A. Badano, I. S. Kyprianou, R. J. Jennings, and J. Sempau, "Anisotropic imaging performance in breast tomosynthesis," Med. Phys. 34(11), 4076-4091 (2007).
    • (2007) Med. Phys. , vol.34 , Issue.11 , pp. 4076-4091
    • Badano, A.1    Kyprianou, I.S.2    Jennings, R.J.3    Sempau, J.4
  • 3
    • 33748303079 scopus 로고    scopus 로고
    • Resolution at oblique incidence angles of a flat panel imager for breast tomosynthesis
    • J. G. Mainprize, A. K. Bloomquist, M. P. Kempston, and M. J. Yaffe, "Resolution at oblique incidence angles of a flat panel imager for breast tomosynthesis," Med. Phys. 33(9), 3159-3164 (2006).
    • (2006) Med. Phys. , vol.33 , Issue.9 , pp. 3159-3164
    • Mainprize, J.G.1    Bloomquist, A.K.2    Kempston, M.P.3    Yaffe, M.J.4
  • 4
    • 0028941060 scopus 로고
    • X-ray imaging using amorphous selenium: Inherent spatial resolution
    • W. Que and J. A. Rowlands, "X-ray imaging using amorphous selenium: Inherent spatial resolution," Med. Phys. 22(4), 365-374 (1995).
    • (1995) Med. Phys. , vol.22 , Issue.4 , pp. 365-374
    • Que, W.1    Rowlands, J.A.2
  • 5
    • 65549148766 scopus 로고    scopus 로고
    • Experimental validation of Monte Carlo (MANTIS) simulated x-ray response of columnar CsI scintillator screens
    • M. Freed, S. Miller, K. Tang, and A. Badano, "Experimental validation of Monte Carlo (MANTIS) simulated x-ray response of columnar CsI scintillator screens," Med. Phys. 36(11), 4944-4956 (2009).
    • (2009) Med. Phys. , vol.36 , Issue.11 , pp. 4944-4956
    • Freed, M.1    Miller, S.2    Tang, K.3    Badano, A.4
  • 6
    • 65549096469 scopus 로고    scopus 로고
    • Effect of oblique x-ray incidence in flat-panel computed tomography of the breast
    • A. Badano, I. S. Kyprianou, M. Freed, R. J. Jennings, and J. Sempau, "Effect of oblique x-ray incidence in flat-panel computed tomography of the breast," IEEE Trans. Med. Imaging 28(5), 696-702 (2009).
    • (2009) IEEE Trans. Med. Imaging , vol.28 , Issue.5 , pp. 696-702
    • Badano, A.1    Kyprianou, I.S.2    Freed, M.3    Jennings, R.J.4    Sempau, J.5
  • 7
    • 33644685403 scopus 로고    scopus 로고
    • MANTIS: Combined x-ray, electron and optical Monte Carlo simulations of indirect radiation imaging systems
    • A. Badano and J. Sempau, "MANTIS: Combined x-ray, electron and optical Monte Carlo simulations of indirect radiation imaging systems," Phys. Med. Biol. 51(6), 1545-1561 (2006).
    • (2006) Phys. Med. Biol. , vol.51 , Issue.6 , pp. 1545-1561
    • Badano, A.1    Sempau, J.2
  • 8
    • 79953671061 scopus 로고    scopus 로고
    • Monte Carlo simulation of amorphous selenium imaging detectors
    • Y. Fang, A. Badal, N. Allec, K. Karim, and A. Badano, "Monte Carlo simulation of amorphous selenium imaging detectors," Proc. SPIE 7622, 762214-1-762214-9 (2010).
    • (2010) Proc. SPIE , vol.7622 , pp. 7622141-7622149
    • Fang, Y.1    Badal, A.2    Allec, N.3    Karim, K.4    Badano, A.5
  • 9
    • 77953506834 scopus 로고    scopus 로고
    • A fast, angle-dependent, analytical model of CsI detector response for optimization of 3D x-ray breast imaging systems
    • M. Freed, S. Park, and A. Badano, "A fast, angle-dependent, analytical model of CsI detector response for optimization of 3D x-ray breast imaging systems," Med. Phys. 37(6), 2593-2605 (2010).
    • (2010) Med. Phys. , vol.37 , Issue.6 , pp. 2593-2605
    • Freed, M.1    Park, S.2    Badano, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.