메뉴 건너뛰기




Volumn , Issue , 2011, Pages 3863-3870

Dynamic multi-bed FDG PET imaging: Feasibility and optimization

Author keywords

[No Author keywords available]

Indexed keywords

DATA ACQUISITION; HOSPITAL DATA PROCESSING; IMAGE SEGMENTATION; INTELLIGENT SYSTEMS; MONTE CARLO METHODS; PATIENT TREATMENT; PHOSPHORYLATION;

EID: 84863338160     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2011.6153735     Document Type: Conference Paper
Times cited : (34)

References (36)
  • 2
    • 43649094992 scopus 로고    scopus 로고
    • 18FDG PET scanning in oncology
    • DOI 10.1038/sj.bjc.6604330, PII 6604330
    • F. Castell and G. Cook, "Quantitative techniques in 18-FDG PET scanning in oncology," British Journal of Cancer, vol. 98, no. 10, pp. 1597-1601, 2008. (Pubitemid 351684676)
    • (2008) British Journal of Cancer , vol.98 , Issue.10 , pp. 1597-1601
    • Castell, F.1    Cook, G.J.R.2
  • 5
    • 0036156598 scopus 로고    scopus 로고
    • Whole-body FDG-PET imaging in the management of patients with cancer
    • Elsevier
    • R. Hustinx, F. Bénard, and A. Alavi, "Whole-body FDG-PET imaging in the management of patients with cancer*," in Seminars in nuclear medicine, vol. 32, no. 1. Elsevier, 2002, pp. 35-46.
    • (2002) Seminars in Nuclear Medicine , vol.32 , Issue.1 , pp. 35-46
    • Hustinx, R.1    Bénard, F.2    Alavi, A.3
  • 7
    • 41549158607 scopus 로고    scopus 로고
    • Positron emission tomography/computed tomography
    • Elsevier
    • D. Townsend, "Positron emission tomography/computed tomography,"in Seminars in nuclear medicine, vol. 38, no. 3. Elsevier, 2008, pp. 152-166.
    • (2008) Seminars in Nuclear Medicine , vol.38 , Issue.3 , pp. 152-166
    • Townsend, D.1
  • 8
    • 0031834634 scopus 로고    scopus 로고
    • Non-invasive estimation of the net influx constant using the standardized uptake value for quantification of FDG uptake of tumours
    • DOI 10.1007/s002590050256
    • N. Sadato, T. Tsuchida, S. Nakaumra, A. Waki, H. Uematsu, N. Takahashi, N. Hayashi, Y. Yonekura, and Y. Ishii, "Non-invasive estimation of the net influx constant using the standardized uptake value for quantification of FDG uptake of tumours," European Journal of Nuclear Medicine and Molecular Imaging, vol. 25, no. 6, pp. 559-564, 1998. (Pubitemid 28297829)
    • (1998) European Journal of Nuclear Medicine , vol.25 , Issue.6 , pp. 559-564
    • Sadato, N.1    Tsuchida, T.2    Nakaumra, S.3    Waki, A.4    Uematsu, H.5    Takahashi, N.6    Hayashi, N.7    Yonekura, Y.8    Ishii, Y.9
  • 9
    • 0028334646 scopus 로고
    • A clinically practical method to acquire parametric images of unidirectional metabolic rates and blood spaces
    • W. Wong and K. Hicks, "A clinically practical method to acquire parametric images of unidirectional metabolic rates and blood spaces."Journal of Nuclear Medicine, vol. 35, no. 7, p. 1206, 1994.
    • (1994) Journal of Nuclear Medicine , vol.35 , Issue.7 , pp. 1206
    • Wong, W.1    Hicks, K.2
  • 11
    • 0027367203 scopus 로고
    • Standardized uptake values of normal tissues at PET with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose: Variations with body weight and a method for correction
    • K. Zasadny and R. Wahl, "Standardized uptake values of normal tissues at PET with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose: variations with body weight and a method for correction." Radiology, vol. 189, no. 3, p. 847, 1993.
    • (1993) Radiology , vol.189 , Issue.3 , pp. 847
    • Zasadny, K.1    Wahl, R.2
  • 12
    • 0029845837 scopus 로고    scopus 로고
    • Dependency of standardized uptake values of fluorine-18 fluorodeoxyglucose on body size: Comparison of body surface area correction and lean body mass correction
    • C. Kim, N. Gupta et al., "Dependency of standardized uptake values of fluorine-18 fluorodeoxyglucose on body size: comparison of body surface area correction and lean body mass correction." Nuclear medicine communications, vol. 17, no. 10, p. 890, 1996.
    • (1996) Nuclear Medicine Communications , vol.17 , Issue.10 , pp. 890
    • Kim, C.1    Gupta, N.2
  • 13
    • 0027982920 scopus 로고
    • Standardized uptake values of FDG: Body surface area correction is preferable to body weight correction
    • C. Kim, N. Gupta, B. Chandramouli, A. Alavi et al., "Standardized uptake values of FDG: body surface area correction is preferable to body weight correction." Journal of Nuclear Medicine, vol. 35, no. 1, p. 164, 1994.
    • (1994) Journal of Nuclear Medicine , vol.35 , Issue.1 , pp. 164
    • Kim, C.1    Gupta, N.2    Chandramouli, B.3    Alavi, A.4
  • 14
    • 0028122283 scopus 로고
    • The dose uptake ratio as an index of glucose metabolism: Useful parameter or oversimplification?
    • L. Hamberg, G. Hunter, N. Alpert, N. Choi, J. Babich, and A. Fischman, "The dose uptake ratio as an index of glucose metabolism: Useful parameter or oversimplification?" Journal of Nuclear Medicine, vol. 35, no. 8, p. 1308, 1994.
    • (1994) Journal of Nuclear Medicine , vol.35 , Issue.8 , pp. 1308
    • Hamberg, L.1    Hunter, G.2    Alpert, N.3    Choi, N.4    Babich, J.5    Fischman, A.6
  • 15
    • 0028784446 scopus 로고
    • SUV: Standard uptake or silly useless value?
    • J. Keyes Jr et al., "SUV: Standard uptake or silly useless value?" Journal of Nuclear Medicine, vol. 36, no. 10, p. 1836, 1995.
    • (1995) Journal of Nuclear Medicine , vol.36 , Issue.10 , pp. 1836
    • Keyes Jr., J.1
  • 16
    • 0033737712 scopus 로고    scopus 로고
    • Anatomy of SUV
    • S. Huang, "Anatomy of SUV," Nuclear Medicine and Biology, vol. 27, no. 7, pp. 643-646, 2000.
    • (2000) Nuclear Medicine and Biology , vol.27 , Issue.7 , pp. 643-646
    • Huang, S.1
  • 17
    • 77955603274 scopus 로고    scopus 로고
    • A systematic review of the factors affecting accuracy of SUV measurements
    • M. Adams, T. Turkington, J. Wilson, and T. Wong, "A systematic review of the factors affecting accuracy of SUV measurements," American Journal of Roentgenology, vol. 195, no. 2, pp. 310-320, 2010.
    • (2010) American Journal of Roentgenology , vol.195 , Issue.2 , pp. 310-320
    • Adams, M.1    Turkington, T.2    Wilson, J.3    Wong, T.4
  • 21
    • 0019794669 scopus 로고
    • High- and low-affinity transport of D-glucose from blood to brain
    • DOI 10.1111/j.1471-4159.1981.tb00587.x
    • A. Gjedde, "High-and low-affinity transport of D-glucose from blood to brain," Journal of Neurochemistry, vol. 36, no. 4, pp. 1463-1471, 1981. (Pubitemid 11070813)
    • (1981) Journal of Neurochemistry , vol.36 , Issue.4 , pp. 1463-1471
    • Gjedde, A.1
  • 22
    • 73749084522 scopus 로고    scopus 로고
    • Multi-graphical analysis of dynamic PET
    • Y. Zhou, W. Ye, J. Brasic, and D. Wong, "Multi-graphical analysis of dynamic PET," Neuroimage, vol. 49, no. 4, pp. 2947-2957, 2010.
    • (2010) Neuroimage , vol.49 , Issue.4 , pp. 2947-2957
    • Zhou, Y.1    Ye, W.2    Brasic, J.3    Wong, D.4
  • 23
    • 0022389649 scopus 로고
    • Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. Generalizations
    • C. Patlak and R. Blasberg, "Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. generalizations," Journal of Cerebral Blood Flow & Metabolism, vol. 5, no. 4, pp. 584-590, 1985. (Pubitemid 16218234)
    • (1985) Journal of Cerebral Blood Flow and Metabolism , vol.5 , Issue.4 , pp. 584-590
    • Patlak, C.S.1    Blasberg, R.G.2
  • 26
    • 72249112713 scopus 로고    scopus 로고
    • Quantitative, dynamic 18F-FDG-PET for the evaluation of soft tissue sarcomas: Relation to differential diagnosis, tumor grading and prediction of prognosis
    • S. Okazumi, A. Dimitrakopoulou-Strauss, M. Schwarzbach, and L. Strauss, "Quantitative, dynamic 18F-FDG-PET for the evaluation of soft tissue sarcomas: relation to differential diagnosis, tumor grading and prediction of prognosis." Hellenic journal of Nuclear Medicine, vol. 12, no. 3, p. 223, 2009.
    • (2009) Hellenic Journal of Nuclear Medicine , vol.12 , Issue.3 , pp. 223
    • Okazumi, S.1    Dimitrakopoulou-Strauss, A.2    Schwarzbach, M.3    Strauss, L.4
  • 28
    • 0032929519 scopus 로고    scopus 로고
    • Germ cell tumor: Differentiation of viable tumor, mature teratoma, and necrotic tissue with FDG PET and kinetic modeling
    • Y. Sugawara, K. Zasadny, H. Grossman, I. Francis, M. Clarke, and R. Wahl, "Germ cell tumor: Differentiation of viable tumor, mature teratoma, and necrotic tissue with FDG PET and kinetic modeling,"Radiology, vol. 211, no. 1, pp. 249-256, 1999. (Pubitemid 29161760)
    • (1999) Radiology , vol.211 , Issue.1 , pp. 249-256
    • Sugawara, Y.1    Zasadny, K.R.2    Grossman, H.B.3    Francis, I.R.4    Clarke, M.F.5    Wahl, R.L.6
  • 29
    • 0035125648 scopus 로고    scopus 로고
    • 15O-water using compartment and noncompartment analysis
    • A. Dimitrakopoulou-Strauss, L. Strauss, and C. Burger, "Quantitative PET studies in pretreated melanoma patients: a comparison of 6-[18F] fluoro-L-dopa with 18F-FDG and I5O-water using compartment and noncompartment analysis," Journal of Nuclear Medicine, vol. 42, no. 2, pp. 248-256, 2001. (Pubitemid 32150515)
    • (2001) Journal of Nuclear Medicine , vol.42 , Issue.2 , pp. 248-256
    • Dimitrakopoulou-Strauss, A.1    Strauss, L.G.2    Burger, C.3
  • 32


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.