메뉴 건너뛰기




Volumn 49, Issue 4, 2010, Pages 2947-2957

Multi-graphical analysis of dynamic PET

Author keywords

Gjedde Patlak plot; Logan plot; PET; RE plot; Relative equilibrium

Indexed keywords

3BETA (4 FLUOROPHENYL) 2BETA TROPANECARBOXYLIC ACID METHYL ESTER; CARBON 11; TRACER; VOLINANSERIN;

EID: 73749084522     PISSN: 10538119     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.neuroimage.2009.11.028     Document Type: Article
Times cited : (44)

References (49)
  • 2
    • 0002357422 scopus 로고
    • An information criteria (AIC)
    • Akaike, H., 1976. An information criteria (AIC). Math. Sci. 14, 5-9.
    • (1976) Math. Sci , vol.14 , pp. 5-9
    • Akaike, H.1
  • 4
    • 0033117043 scopus 로고    scopus 로고
    • Dopamine imaging markers and predictive mathematical models for progressive degeneration in Parkinson's disease
    • Brownell A.L., Jenkins B.G., and Isacson O. Dopamine imaging markers and predictive mathematical models for progressive degeneration in Parkinson's disease. Biomed. Pharmacother. 53 3 (1999) 131-140
    • (1999) Biomed. Pharmacother. , vol.53 , Issue.3 , pp. 131-140
    • Brownell, A.L.1    Jenkins, B.G.2    Isacson, O.3
  • 5
    • 0038028819 scopus 로고    scopus 로고
    • Improved statistical power of the multilinear reference tissue approach to the quantification of neuroreceptor ligandbinding by regularization
    • Buchert, R., Wilke, F., van den Hoff, J., Mester, J., 2003. Improved statistical power of the multilinear reference tissue approach to the quantification of neuroreceptor ligandbinding by regularization. J. Cereb. Blood Flow Metab. 23 (5), 612-620.
    • (2003) J. Cereb. Blood Flow Metab , vol.23 , Issue.5 , pp. 612-620
    • Buchert, R.1    Wilke, F.2    van den Hoff, J.3    Mester, J.4
  • 8
    • 68749114058 scopus 로고    scopus 로고
    • Strategies for the generation of parametric images of [(11)C]PIB with plasma input functions considering discriminations and reproducibility
    • Edison P., Brooks D.J., Turkheimer F.E., Archer H.A., and Hinz R. Strategies for the generation of parametric images of [(11)C]PIB with plasma input functions considering discriminations and reproducibility. NeuroImage 48 (2009) 329-338
    • (2009) NeuroImage , vol.48 , pp. 329-338
    • Edison, P.1    Brooks, D.J.2    Turkheimer, F.E.3    Archer, H.A.4    Hinz, R.5
  • 9
    • 34248155550 scopus 로고    scopus 로고
    • Identification and interpretation of microparameters in neuroreceptor compartmental models
    • Cunningham V.J., Matthews J.C., Gunn R.N., Rabiner E.A., and Gee A.D. Identification and interpretation of microparameters in neuroreceptor compartmental models. NeuroImage 22 Suppl. 2 (2004) T13-T14
    • (2004) NeuroImage , vol.22 , Issue.SUPPL. 2
    • Cunningham, V.J.1    Matthews, J.C.2    Gunn, R.N.3    Rabiner, E.A.4    Gee, A.D.5
  • 10
    • 0027296568 scopus 로고
    • Positron emission tomographic imaging of the dopamine transporter with 11C-WIN 35,428 reveals marked declines in mild Parkinson's disease
    • Frost J.J., Rosier A.J., Reich S.G., Smith J.S., Ehlers M.D., Snyder S.H., Ravert H.T., and Dannals R.F. Positron emission tomographic imaging of the dopamine transporter with 11C-WIN 35,428 reveals marked declines in mild Parkinson's disease. Ann. Neurol. 34 3 (1993) 423-431
    • (1993) Ann. Neurol. , vol.34 , Issue.3 , pp. 423-431
    • Frost, J.J.1    Rosier, A.J.2    Reich, S.G.3    Smith, J.S.4    Ehlers, M.D.5    Snyder, S.H.6    Ravert, H.T.7    Dannals, R.F.8
  • 11
    • 0019794669 scopus 로고
    • High- and low-affinity transport of D-Glucose from blood to brain
    • Gjedde A. High- and low-affinity transport of D-Glucose from blood to brain. J. Neurochem. 36 (1981) 1463-1471
    • (1981) J. Neurochem. , vol.36 , pp. 1463-1471
    • Gjedde, A.1
  • 12
    • 0343580507 scopus 로고    scopus 로고
    • Time course of 5-HT2A receptor occupancy in the human brain after a single oral dose of the putative antipsychotic drug MDL 100,907 measured by positron emission tomography
    • Erratum in: Neuropsychopharmacology 1998, 19(2):161
    • Gründer G., Yokoi F., Offord S.J., Ravert H.T., Dannals R.F., Salzmann J.K., Szymanski S., Wilson P.D., Howard D.R., and Wong D.F. Time course of 5-HT2A receptor occupancy in the human brain after a single oral dose of the putative antipsychotic drug MDL 100,907 measured by positron emission tomography. Neuropsychopharmacology 17 3 (1997) 175-185 Erratum in: Neuropsychopharmacology 1998, 19(2):161
    • (1997) Neuropsychopharmacology , vol.17 , Issue.3 , pp. 175-185
    • Gründer, G.1    Yokoi, F.2    Offord, S.J.3    Ravert, H.T.4    Dannals, R.F.5    Salzmann, J.K.6    Szymanski, S.7    Wilson, P.D.8    Howard, D.R.9    Wong, D.F.10
  • 14
    • 0034672836 scopus 로고    scopus 로고
    • Autoradiographic localization of 5-HT(2A) receptors in the human brain using [(3)H]M100907 and [(11)C]M100907
    • Hall H., Farde L., Halldin C., Lundkvist C., and Sedvall G. Autoradiographic localization of 5-HT(2A) receptors in the human brain using [(3)H]M100907 and [(11)C]M100907. Synapse 38 4 (2000) 421-431
    • (2000) Synapse , vol.38 , Issue.4 , pp. 421-431
    • Hall, H.1    Farde, L.2    Halldin, C.3    Lundkvist, C.4    Sedvall, G.5
  • 15
    • 33845732318 scopus 로고    scopus 로고
    • Validation of a tracer kinetic model for the quantification of 5-HT(2A) receptors in human brain with [(11)C]MDL 100,907
    • Hinz R., Bhagwagar Z., Cowen P.J., Cunningham V.J., and Grasby P.M. Validation of a tracer kinetic model for the quantification of 5-HT(2A) receptors in human brain with [(11)C]MDL 100,907. J. Cereb. Blood Flow Metab. 27 1 (2007) 161-172
    • (2007) J. Cereb. Blood Flow Metab. , vol.27 , Issue.1 , pp. 161-172
    • Hinz, R.1    Bhagwagar, Z.2    Cowen, P.J.3    Cunningham, V.J.4    Grasby, P.M.5
  • 16
    • 0000950415 scopus 로고
    • Principles of tracer kinetic modeling in positron emission tomography and autoradiography
    • Phelps M.E., Mazziotta J.C., Schelbert H.R., (Eds), Raven Press, New York
    • Huang S.C., and Phelps M.E. Principles of tracer kinetic modeling in positron emission tomography and autoradiography. In: Phelps M.E., Mazziotta J.C., Schelbert H.R., (Eds). Positron Emission Tomography and Autoradiography: Principles and Applications for the Brain and Heart (1986), Raven Press, New York 287-346
    • (1986) Positron Emission Tomography and Autoradiography: Principles and Applications for the Brain and Heart , pp. 287-346
    • Huang, S.C.1    Phelps, M.E.2
  • 18
    • 0022980281 scopus 로고
    • Neuroreceptor assay with positron emission tomography: equilibrium versus dynamic approaches
    • Huang S.C., Barrio J.R., and Phelps M.E. Neuroreceptor assay with positron emission tomography: equilibrium versus dynamic approaches. J. Cereb. Blood Flow Metab. 6 5 (1986) 515-521
    • (1986) J. Cereb. Blood Flow Metab. , vol.6 , Issue.5 , pp. 515-521
    • Huang, S.C.1    Barrio, J.R.2    Phelps, M.E.3
  • 19
    • 0031930011 scopus 로고    scopus 로고
    • PET imaging of central 5-HT2A receptors with carbon-11-MDL 100,907
    • Ito H., Nyberg S., Halldin C., Lundkvist C., and Farde L. PET imaging of central 5-HT2A receptors with carbon-11-MDL 100,907. J. Nucl. Med. 39 1 (1998) 208-214
    • (1998) J. Nucl. Med. , vol.39 , Issue.1 , pp. 208-214
    • Ito, H.1    Nyberg, S.2    Halldin, C.3    Lundkvist, C.4    Farde, L.5
  • 20
    • 0036792015 scopus 로고    scopus 로고
    • Strategies to improve neuroreceptor parameter estimation by linear regression analysis
    • Ichise M., Toyama H., Innis R.B., and Carson R.E. Strategies to improve neuroreceptor parameter estimation by linear regression analysis. J. Cereb. Blood Flow Metab. 22 10 (2002) 1271-1281
    • (2002) J. Cereb. Blood Flow Metab. , vol.22 , Issue.10 , pp. 1271-1281
    • Ichise, M.1    Toyama, H.2    Innis, R.B.3    Carson, R.E.4
  • 21
    • 34547846251 scopus 로고    scopus 로고
    • Consensus nomenclature for in vivo imaging of reversibly binding radioligands
    • Innis R.B., Cunningham V.J., Delforge J., et al. Consensus nomenclature for in vivo imaging of reversibly binding radioligands. J. Cereb. Blood Flow Metab. 27 9 (2007) 1533-1539
    • (2007) J. Cereb. Blood Flow Metab. , vol.27 , Issue.9 , pp. 1533-1539
    • Innis, R.B.1    Cunningham, V.J.2    Delforge, J.3
  • 22
    • 41149155943 scopus 로고    scopus 로고
    • Improving PET receptor binding estimates from Logan plots using principal component analysis
    • Joshi A., Fessler J.A., and Koeppe R.A. Improving PET receptor binding estimates from Logan plots using principal component analysis. J. Cereb. Blood Flow Metab. 28 4 (2008) 852-865
    • (2008) J. Cereb. Blood Flow Metab. , vol.28 , Issue.4 , pp. 852-865
    • Joshi, A.1    Fessler, J.A.2    Koeppe, R.A.3
  • 23
  • 24
    • 0025925363 scopus 로고
    • Compartmental analysis of [11C]flumazenil kinetics for the estimation of ligand transport rate and receptor distribution using positron emission tomography
    • Koeppe R.A., Holthoff V.A., Frey K.A., Kilbourn M.R., and Kuhl D.E. Compartmental analysis of [11C]flumazenil kinetics for the estimation of ligand transport rate and receptor distribution using positron emission tomography. J. Cereb. Blood Flow Metab. 11 (1991) 735-744
    • (1991) J. Cereb. Blood Flow Metab. , vol.11 , pp. 735-744
    • Koeppe, R.A.1    Holthoff, V.A.2    Frey, K.A.3    Kilbourn, M.R.4    Kuhl, D.E.5
  • 26
    • 0347854380 scopus 로고    scopus 로고
    • A review of graphical methods for tracer studies and strategies to reduce bias
    • Logan J. A review of graphical methods for tracer studies and strategies to reduce bias. Nucl. Med. Biol. 30 8 (2003) 833-844
    • (2003) Nucl. Med. Biol. , vol.30 , Issue.8 , pp. 833-844
    • Logan, J.1
  • 28
    • 0029869731 scopus 로고    scopus 로고
    • [11C]MDL 100907, a radioligand for selective imaging of 5-HT(2A) receptors with positron emission tomography
    • Erratum in: Life Sci 58(25):379
    • Lundkvist C., Halldin C., Ginovart N., Nyberg S., Swahn C.G., Carr A.A., Brunner F., and Farde L. [11C]MDL 100907, a radioligand for selective imaging of 5-HT(2A) receptors with positron emission tomography. Life Sci. 58 10 (1996) 187-192 Erratum in: Life Sci 58(25):379
    • (1996) Life Sci. , vol.58 , Issue.10 , pp. 187-192
    • Lundkvist, C.1    Halldin, C.2    Ginovart, N.3    Nyberg, S.4    Swahn, C.G.5    Carr, A.A.6    Brunner, F.7    Farde, L.8
  • 29
    • 0000169232 scopus 로고
    • An algorithm for least-squares estimations of nonlinear parameters
    • Marquardt D.W. An algorithm for least-squares estimations of nonlinear parameters. J. Soc. Ind. Appl. Math. 11 (1963) 431-441
    • (1963) J. Soc. Ind. Appl. Math. , vol.11 , pp. 431-441
    • Marquardt, D.W.1
  • 30
    • 0021364348 scopus 로고
    • A quantitative model for the in vivo assessment of drug binding sites with positron emission tomography
    • Mintun M.A., Raichle M.E., Kilbourn M.R., Wooten G.F., and Welch M.J. A quantitative model for the in vivo assessment of drug binding sites with positron emission tomography. Ann. Neurol. 15 (1984) 217-227
    • (1984) Ann. Neurol. , vol.15 , pp. 217-227
    • Mintun, M.A.1    Raichle, M.E.2    Kilbourn, M.R.3    Wooten, G.F.4    Welch, M.J.5
  • 31
    • 0242439627 scopus 로고    scopus 로고
    • Estimation of kinetic parameters in graphical analysis of PET imaging data
    • Ogden R.T. Estimation of kinetic parameters in graphical analysis of PET imaging data. Stat. Med. 22 22 (2003) 3557-3568
    • (2003) Stat. Med. , vol.22 , Issue.22 , pp. 3557-3568
    • Ogden, R.T.1
  • 32
    • 0022389649 scopus 로고
    • Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. Generalizations
    • Patlak C.S., and Blasberg R.G. Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. Generalizations. J. Cereb. Blood Flow Metab. 5 (1985) 584-590
    • (1985) J. Cereb. Blood Flow Metab. , vol.5 , pp. 584-590
    • Patlak, C.S.1    Blasberg, R.G.2
  • 33
    • 0020956774 scopus 로고
    • Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data
    • Patlak C.S., Blasberg R.G., and Fenstermacher J.D. Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. J. Cereb. Blood Flow Metab. 3 1 (1983) 1-7
    • (1983) J. Cereb. Blood Flow Metab. , vol.3 , Issue.1 , pp. 1-7
    • Patlak, C.S.1    Blasberg, R.G.2    Fenstermacher, J.D.3
  • 34
    • 68149124453 scopus 로고    scopus 로고
    • Direct 4D parametric image estimation in reversible tracer binding imaging
    • Rahmim A., Zhou Y., and Tang T. Direct 4D parametric image estimation in reversible tracer binding imaging. J. Nucl. Med. 50 (2009) 137P
    • (2009) J. Nucl. Med. , vol.50
    • Rahmim, A.1    Zhou, Y.2    Tang, T.3
  • 35
    • 0036074323 scopus 로고    scopus 로고
    • Kinetic modeling in positron emission tomography
    • Review
    • Schmidt K.C., and Turkheimer F.E. Kinetic modeling in positron emission tomography. Q. J. Nucl. Med. 46 1 (2002) 70-85 Review
    • (2002) Q. J. Nucl. Med. , vol.46 , Issue.1 , pp. 70-85
    • Schmidt, K.C.1    Turkheimer, F.E.2
  • 36
    • 0034520848 scopus 로고    scopus 로고
    • Effects of statistical noise on graphic analysis of PET neuroreceptor studies
    • Slifstein M., and Laruelle M. Effects of statistical noise on graphic analysis of PET neuroreceptor studies. J. Nucl. Med. 41 (2000) 2083-2088
    • (2000) J. Nucl. Med. , vol.41 , pp. 2083-2088
    • Slifstein, M.1    Laruelle, M.2
  • 37
    • 0037383650 scopus 로고    scopus 로고
    • On the undecidability among kinetic models: from model selection to model averaging
    • Turkheimer F.E., Hinz R., and Cunningham V.J. On the undecidability among kinetic models: from model selection to model averaging. J. Cereb. Blood Flow Metab. 23 (2003) 490-498
    • (2003) J. Cereb. Blood Flow Metab. , vol.23 , pp. 490-498
    • Turkheimer, F.E.1    Hinz, R.2    Cunningham, V.J.3
  • 38
    • 0036168351 scopus 로고    scopus 로고
    • Modified regression model for the Logan plot
    • Varga, J., Szabo, Z., 2002. Modified regression model for the Logan plot. J. Cereb. Blood Flow Metab. 22 (2), 240-244.
    • (2002) J. Cereb. Blood Flow Metab , vol.22 , Issue.2 , pp. 240-244
    • Varga, J.1    Szabo, Z.2
  • 40
    • 0022601992 scopus 로고
    • Quantification of neuroreceptors in the living human brain. I. Irreversible binding of ligands
    • Wong D.F., Gjedde A., and Wagner Jr. H.N. Quantification of neuroreceptors in the living human brain. I. Irreversible binding of ligands. J. Cereb. Blood Flow Metab. 6 (1986) 137-146
    • (1986) J. Cereb. Blood Flow Metab. , vol.6 , pp. 137-146
    • Wong, D.F.1    Gjedde, A.2    Wagner Jr., H.N.3
  • 42
    • 0029062278 scopus 로고
    • The assessment of the non-equilibrium effect in the 'Patlak analysis' of Fdopa PET studies
    • Yu D.C., Huang S.C., Barrio J.R., and Phelps M.E. The assessment of the non-equilibrium effect in the 'Patlak analysis' of Fdopa PET studies. Phys. Med. Biol. 40 7 (1995) 1243-1254
    • (1995) Phys. Med. Biol. , vol.40 , Issue.7 , pp. 1243-1254
    • Yu, D.C.1    Huang, S.C.2    Barrio, J.R.3    Phelps, M.E.4
  • 43
    • 0036335209 scopus 로고    scopus 로고
    • Improved parametric image generation using spatial-temporal analysis of dynamic PET studies
    • Zhou, Y., Huang, S.C., Bergsneider, M., Wong, D.F., 2002. Improved parametric image generation using spatial-temporal analysis of dynamic PET studies. NeuroImage 15, 697-707.
    • (2002) NeuroImage , vol.15 , pp. 697-707
    • Zhou, Y.1    Huang, S.C.2    Bergsneider, M.3    Wong, D.F.4
  • 44
    • 0037396522 scopus 로고    scopus 로고
    • Linear regression with spatial constraint to generate parametric images of ligand-receptor dynamic PET studies with a simplified reference tissue model
    • Zhou Y., Endres C.J., Brašić J.R., Huang S.C., and Wong D.F. Linear regression with spatial constraint to generate parametric images of ligand-receptor dynamic PET studies with a simplified reference tissue model. Neuroimage 18 4 (2003) 975-989
    • (2003) Neuroimage , vol.18 , Issue.4 , pp. 975-989
    • Zhou, Y.1    Endres, C.J.2    Brašić, J.R.3    Huang, S.C.4    Wong, D.F.5
  • 47
    • 73749088250 scopus 로고    scopus 로고
    • Using a consistent graphical analysis method to improve the voxel-wise quantification of [11C]PIB dynamic PET
    • Zhou Y., Resnick S., Ye W., Sojkova J., and Wong D.F. Using a consistent graphical analysis method to improve the voxel-wise quantification of [11C]PIB dynamic PET. J. Nucl. Med. 50 (2009) 31P
    • (2009) J. Nucl. Med. , vol.50
    • Zhou, Y.1    Resnick, S.2    Ye, W.3    Sojkova, J.4    Wong, D.F.5
  • 48
    • 57649219957 scopus 로고    scopus 로고
    • A consistent and efficient graphical analysis method to improve the quantification of reversible tracer binding in radioligand receptor dynamic PET studies
    • Zhou Y., Ye W., Brašić J.R., Crabb A.H., Hilton J., and Wong D.F. A consistent and efficient graphical analysis method to improve the quantification of reversible tracer binding in radioligand receptor dynamic PET studies. NeuroImage 44 3 (2009) 661-670
    • (2009) NeuroImage , vol.44 , Issue.3 , pp. 661-670
    • Zhou, Y.1    Ye, W.2    Brašić, J.R.3    Crabb, A.H.4    Hilton, J.5    Wong, D.F.6
  • 49
    • 73749088250 scopus 로고    scopus 로고
    • Evaluation of a consistent bi-graphical plot to quantify relative slow tracer kinetics in ligand-receptor dynamic PET studies
    • Zhou Y., Ye W., Brašić J.R., and Wong D.F. Evaluation of a consistent bi-graphical plot to quantify relative slow tracer kinetics in ligand-receptor dynamic PET studies. J. Nucl. Med. 50 (2009) 31P
    • (2009) J. Nucl. Med. , vol.50
    • Zhou, Y.1    Ye, W.2    Brašić, J.R.3    Wong, D.F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.