메뉴 건너뛰기




Volumn 27, Issue 5, 2012, Pages 2376-2384

LVRT scheme of PMSG wind power systems based on feedback linearization

Author keywords

DC link voltage; feedback linearization; permanent magnet synchronous generator (PMSG); ride through; wind power

Indexed keywords

ACTIVE POWER; DC-LINK VOLTAGES; FEEDBACK LINEARIZATION THEORY; GRID VOLTAGE; GRID-SIDE CONVERTER; LOW-VOLTAGE RIDE-THROUGH; MAXIMUM POWER POINT TRACKING; NON-LINEAR RELATIONSHIPS; PERMANENT MAGNET SYNCHRONOUS GENERATOR; PERMANENT MAGNET SYNCHRONOUS GENERATOR (PMSG); RIDE-THROUGH; WIND TURBINE SIMULATOR;

EID: 84863242882     PISSN: 08858993     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPEL.2011.2171999     Document Type: Article
Times cited : (274)

References (30)
  • 1
    • 33244483622 scopus 로고    scopus 로고
    • Control of permanent-magnet generators applied to variable-speed wind-energy systems connected to the grid
    • DOI 10.1109/TEC.2005.853735
    • M. Chinchilla, S. Arnaltes, and J. C. Burgos, "Control of permanentmagnet generators applied to variable-speed wind-energy systems connected to the grid," IEEE Trans. Energy Convers., vol. 21, no. 1, pp. 130-135, Mar. 2006. (Pubitemid 43280527)
    • (2006) IEEE Transactions on Energy Conversion , vol.21 , Issue.1 , pp. 130-135
    • Chinchilla, M.1    Arnaltes, S.2    Burgos, J.C.3
  • 2
    • 33947414834 scopus 로고    scopus 로고
    • Comparison of direct-drive and geared generator concepts for wind turbines
    • Sep
    • H. Polinder, F. F.Avan der Pijl, and P. Tavner, "Comparison of direct-drive and geared generator concepts for wind turbines," IEEE Trans. Energy Convers., vol. 21, no. 3, pp. 543-550, Sep. 2006.
    • (2006) IEEE Trans. Energy Convers. , vol.21 , Issue.3 , pp. 543-550
    • Polinder, H.1    Avan Der Pijl, F.F.2    Tavner, P.3
  • 4
    • 47249119281 scopus 로고    scopus 로고
    • Test bench for grid code simulations for multi-MW wind turbines, design and control
    • Jul
    • C. Saniter and J. Janning, "Test bench for grid code simulations for multi-MW wind turbines, design and control," IEEE Trans. Power Electron., vol. 23, no. 4, pp. 1707-1715, Jul. 2008.
    • (2008) IEEE Trans. Power Electron. , vol.23 , Issue.4 , pp. 1707-1715
    • Saniter, C.1    Janning, J.2
  • 5
    • 58249097741 scopus 로고    scopus 로고
    • Development of simulator system for micro-grids with renewable energy sources
    • Feb
    • J.-H. Jeon, S.-K. Kim, C.-H.Cho, J.-B.Ahn, and E.-S. Kim, "Development of simulator system for micro-grids with renewable energy sources," J. Electr. Eng. Technol., vol. 1, no. 4, pp. 409-413, Feb. 2006.
    • (2006) J. Electr. Eng. Technol. , vol.1 , Issue.4 , pp. 409-413
    • Jeon, J.-H.1    Kim, S.-K.2    Cho, C.-H.3    Ahn, J.-B.4    Kim, E.-S.5
  • 6
    • 77956529584 scopus 로고    scopus 로고
    • Green recovery: A new program to create good jobs and start building a low-carbon economy
    • Washington, DC, Sep. Available:
    • R. Pollin, H. G. Peltier, and H. Scharber, "Green recovery: A new program to create good jobs and start building a low-carbon economy," Center for American Progress, Washington, DC, Sep. 2008. Available: http://www.peri.umass.edu/fileadmin/pdf/other-publication-types/green-economics/ peri-report.pdf.
    • (2008) Center for American Progress
    • Pollin, R.1    Peltier, H.G.2    Scharber, H.3
  • 7
    • 76649127421 scopus 로고    scopus 로고
    • Rotor voltage dynamics in the doubly fed induction generator during grid faults
    • Jan
    • F. K. A. Lima, A. Luna, P. Rodriguez, E. H. Watanabe, and F. Blaabjerg, "Rotor voltage dynamics in the doubly fed induction generator during grid faults," IEEE Trans. Power Electron., vol. 25, no. 1, pp. 118-130, Jan. 2010.
    • (2010) IEEE Trans. Power Electron. , vol.25 , Issue.1 , pp. 118-130
    • Lima, F.K.A.1    Luna, A.2    Rodriguez, P.3    Watanabe, E.H.4    Blaabjerg, F.5
  • 8
    • 77957014951 scopus 로고    scopus 로고
    • Decoupled-DFIG fault ridethrough strategy for enhanced stability performance during grid faults
    • Oct
    • L. G.Meegahapola, T. Littler, and D. Flynn, "Decoupled-DFIG fault ridethrough strategy for enhanced stability performance during grid faults," IEEE Trans. Sustainable Energy, no. 3, pp. 152-162, Oct. 2010.
    • (2010) IEEE Trans. Sustainable Energy , Issue.3 , pp. 152-162
    • Meegahapola, L.G.1    Littler, T.2    Flynn, D.3
  • 9
    • 61649088161 scopus 로고    scopus 로고
    • Control of a cascade STATCOM with star configuration under unbalanced conditions
    • Jan
    • Q. Song and W. Liu, "Control of a cascade STATCOM with star configuration under unbalanced conditions," IEEE Trans. Power Electron., vol. 24, no. 1, pp. 45-58, Jan. 2009.
    • (2009) IEEE Trans. Power Electron. , vol.24 , Issue.1 , pp. 45-58
    • Song, Q.1    Liu, W.2
  • 10
    • 78649381765 scopus 로고    scopus 로고
    • Setting considerations of distance relay for transmission line with STATCOM
    • Jul
    • W. H. Zhang, S.-J. Lee, andM.-S. Choi, "Setting considerations of distance relay for transmission line with STATCOM," J. Electr. Eng. Technol., vol. 5, no. 4, pp. 522-529, Jul. 2010.
    • (2010) J. Electr. Eng. Technol. , vol.5 , Issue.4 , pp. 522-529
    • Zhang, W.H.1    Lee, S.-J.2    Choi, M.-S.3
  • 11
    • 77956917826 scopus 로고    scopus 로고
    • Modular multilevel converter based STATCOM topology suitable for medium-voltage unbalanced systems
    • Sep
    • H. M. Pirouzy and M. T. Bina, "Modular multilevel converter based STATCOM topology suitable for medium-voltage unbalanced systems," J. Power Electron., vol. 10, no. 5, pp. 572-578, Sep. 2010.
    • (2010) J. Power Electron. , vol.10 , Issue.5 , pp. 572-578
    • Pirouzy, H.M.1    Bina, M.T.2
  • 12
    • 27944478080 scopus 로고    scopus 로고
    • Control method of a braking chopper to reduce voltage unbalance in a 3-level chopper
    • Proceedings of the 2004 IEEE International Conference on Industrial Technology, ICIT
    • G. Brando, A. Coccia, and R. Rizzo, "Control method of a braking chopper to reduce voltage unbalance in a 3-level chopper," in Proc. IEEE Int. Conf. Ind. Technol., 2004, vol. 2, pp. 975-978. (Pubitemid 41675097)
    • (2004) Proceedings of the IEEE International Conference on Industrial Technology , vol.2 , pp. 975-978
    • Brando, G.1    Coccia, A.2    Rizzo, R.3
  • 13
    • 34548601309 scopus 로고    scopus 로고
    • Low-voltage ride-through of a full converter wind turbine with permanent magnet generator
    • DOI 10.1049/iet-rpg:20070033
    • J. F. Conroy and R.Watson, "Low-voltage ride-through of a full converter wind turbine with permanent magnet generator," IET Renewable Power. Generation, vol. 1, no. 3, pp. 182-189, Sep. 2007. (Pubitemid 47403812)
    • (2007) IET Renewable Power Generation , vol.1 , Issue.3 , pp. 182-189
    • Conroy, J.F.1    Watson, R.2
  • 14
    • 42449084594 scopus 로고    scopus 로고
    • Control and performance of wind turbine generators based on permanent magnet synchronous machines feeding a diode rectifier
    • Jun
    • W. Li, C. Abbey, and G. Joos, "Control and performance of wind turbine generators based on permanent magnet synchronous machines feeding a diode rectifier," in Proc. IEEE Power Electron. Spec. Conf., Jun., 2006, pp. 1-6.
    • (2006) Proc. IEEE Power Electron. Spec. Conf , pp. 1-6
    • Li, W.1    Abbey, C.2    Joos, G.3
  • 15
    • 77956535982 scopus 로고    scopus 로고
    • Static synchronous compensators (STATCOM):Areview
    • B. Singh, R. Saha, A. Chandra, and K. Al-Haddad, "Static synchronous compensators (STATCOM):Areview," IET Power Electron., vol. 2, no. 4, pp. 297-324, 2009.
    • (2009) IET Power Electron. , vol.2 , Issue.4 , pp. 297-324
    • Singh, B.1    Saha, R.2    Chandra, A.3    Al-Haddad, K.4
  • 16
    • 70349572056 scopus 로고    scopus 로고
    • Multi-pole permanent magnet synchronous generator wind turbines' grid support capability in uninterrupted operation during grid faults
    • A. D. Hansen and G. Michalke, "Multi-pole permanent magnet synchronous generator wind turbines' grid support capability in uninterrupted operation during grid faults," IET Renewable Power Generation, vol. 3, no. 3, pp. 333-348, 2009.
    • (2009) IET Renewable Power Generation , vol.3 , Issue.3 , pp. 333-348
    • Hansen, A.D.1    Michalke, G.2
  • 17
    • 70049099302 scopus 로고    scopus 로고
    • DC-link voltage control of a full power converter forwind generator operating inweak-grid systems
    • Sep
    • X. Yuan, F.Wang, D. Boroyevich, Y. Li, and R. Burgos, "DC-link voltage control of a full power converter forwind generator operating inweak-grid systems," IEEE Trans. Power Electron., vol. 24, no. 9, pp. 2178-2192, Sep. 2009.
    • (2009) IEEE Trans. Power Electron. , vol.24 , Issue.9 , pp. 2178-2192
    • Yuan, X.1    Wang, F.2    Boroyevich, D.3    Li, Y.4    Burgos, R.5
  • 18
    • 0033705678 scopus 로고    scopus 로고
    • DC-bus voltage control of threephase ac/dc PWM converters using feedback linearization
    • May
    • D.-C. Lee, G.-M. Lee, and K.-D. Lee, "DC-bus voltage control of threephase ac/dc PWM converters using feedback linearization," IEEE Trans. Ind. Appl., vol. 36, no. 3, pp. 826-833, May 2000.
    • (2000) IEEE Trans. Ind. Appl. , vol.36 , Issue.3 , pp. 826-833
    • Lee, D.-C.1    Lee, G.-M.2    Lee, K.-D.3
  • 19
    • 76849092258 scopus 로고    scopus 로고
    • Feedback linearization control of three-phase UPS inverter systems
    • Mar
    • D.-E. Kim and D.-C. Lee, "Feedback linearization control of three-phase UPS inverter systems," IEEE Trans. Ind. Electron., vol. 57, no. 3, pp. 963-968, Mar. 2010.
    • (2010) IEEE Trans. Ind. Electron. , vol.57 , Issue.3 , pp. 963-968
    • Kim, D.-E.1    Lee, D.-C.2
  • 22
    • 78650992716 scopus 로고    scopus 로고
    • Application of adaptive network-based fuzzy inference system for sensorless control of PMSG-based wind turbine with nonlinear-load-compensation capabilities
    • Jan
    • M. Singh and A. Chandra, "Application of adaptive network-based fuzzy inference system for sensorless control of PMSG-based wind turbine with nonlinear-load-compensation capabilities," IEEE Trans. Power Electron., vol. 26, no. 1, pp. 165-175, Jan. 2011.
    • (2011) IEEE Trans. Power Electron. , vol.26 , Issue.1 , pp. 165-175
    • Singh, M.1    Chandra, A.2
  • 24
    • 78650971353 scopus 로고    scopus 로고
    • Unified DC-link current control for low-voltage ride-through in current-source-converter-based wind energy conversion systems
    • Jan
    • J. Dai, D. Xu, B.Wu, and N. R. Zargari, "Unified DC-link current control for low-voltage ride-through in current-source-converter-based wind energy conversion systems," IEEE Trans. Power Electron., vol. 26, no. 1, pp. 288-297, Jan. 2011.
    • (2011) IEEE Trans. Power Electron. , vol.26 , Issue.1 , pp. 288-297
    • Dai, J.1    Xu, D.2    Wu, B.3    Zargari, N.R.4
  • 25
    • 72749085352 scopus 로고    scopus 로고
    • Sensorless direct torque and flux-controlled IPM synchronous motor drive at very low speed without signal injection
    • Jan
    • G. Foo and M. F. Rahman, "Sensorless direct torque and flux-controlled IPM synchronous motor drive at very low speed without signal injection," IEEE Trans. Power Electron., vol. 57, no. 1, pp. 395-403, Jan. 2010.
    • (2010) IEEE Trans. Power Electron. , vol.57 , Issue.1 , pp. 395-403
    • Foo, G.1    Rahman, M.F.2
  • 27
    • 1342329431 scopus 로고    scopus 로고
    • Control of series active power filters compensating for source voltage unbalance and current harmonics
    • Feb
    • G.-M. Lee, D.-C. Lee, and J.-K. Seok, "Control of series active power filters compensating for source voltage unbalance and current harmonics," IEEE Trans. Ind. Appl., vol. 51, no. 1, pp. 132-139, Feb. 2004.
    • (2004) IEEE Trans. Ind. Appl. , vol.51 , Issue.1 , pp. 132-139
    • Lee, G.-M.1    Lee, D.-C.2    Seok, J.-K.3
  • 28
    • 33747788780 scopus 로고    scopus 로고
    • Dual current control scheme for PWM converter under unbalanced input voltage conditions
    • DOI 10.1109/41.793344
    • H.-S. Song and K. Nam, "Dual current control scheme forPWMconverter under unbalanced input voltage conditions," IEEE Trans. Ind. Appl., vol. 46, no. 5, pp. 953-959, Oct. 1999. (Pubitemid 30524489)
    • (1999) IEEE Transactions on Industrial Electronics , vol.46 , Issue.5 , pp. 953-959
    • Song, H.-S.1    Nam, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.