Modular multilevel converter based STATCOM topology suitable for medium-voltage unbalanced systems

Author keywords

DC voltage balancing; Medium voltage; Modular multilevel converter; STATCOM; Unbalanced currents

Indexed keywords

ELECTRIC CURRENT REGULATORS; PHASE SHIFT; REACTIVE POWER; STATIC SYNCHRONOUS COMPENSATORS;

EID: 77956917826     PISSN: 15982092     EISSN: None     Source Type: Journal    
DOI: 10.6113/JPE.2010.10.5.572     Document Type: Article
Times cited : (38)

References (20)
  • 2
    • 0032206096 scopus 로고    scopus 로고
    • A power line conditioner using cascade multilevel inverters for distribution systems
    • Nov./Dec.
    • Fang Z. Peng, John Wang, McKeever, Donald J. Adams, "A power line conditioner using cascade multilevel inverters for distribution systems," IEEE Transactions on Industrial Application, Vol.34, No.6, pp.1293-1298, Nov./Dec. 1998.
    • (1998) IEEE Transactions on Industrial Application , vol.34 , Issue.6 , pp. 1293-1298
    • Peng, F.Z.1    Wang, J.2    McKeever3    Adams, D.J.4
  • 3
    • 77952638275 scopus 로고    scopus 로고
    • Design of a cascaded H-Bridge multilevel inverter based on power electronics building blocks and control for high performance
    • Mar.
    • Y. M. Park, H. S. Ryu, H. W. Lee, M. G. Jung, S. H. Lee, "Design of a cascaded H-Bridge multilevel inverter based on power electronics building blocks and control for high performance," Journal of Power Electronics, Vol.10, No.3, pp.262-269, Mar. 2010.
    • (2010) Journal of Power Electronics , vol.10 , Issue.3 , pp. 262-269
    • Park, Y.M.1    Ryu, H.S.2    Lee, H.W.3    Jung, M.G.4    Lee, S.H.5
  • 4
    • 76749147841 scopus 로고    scopus 로고
    • A fault-tolerant control strategy for cascaded h-bridge multilevel rectifiers
    • Jan.
    • H. I. Eini, S. Farhangi, J. L. Schanen, M. K. Fard, "A fault-tolerant control strategy for cascaded h-bridge multilevel rectifiers," Journal of Power Electronics, Vol.10, No.1, pp.34-42, Jan. 2010.
    • (2010) Journal of Power Electronics , vol.10 , Issue.1 , pp. 34-42
    • Eini, H.I.1    Farhangi, S.2    Schanen, J.L.3    Fard, M.K.4
  • 5
    • 58849141248 scopus 로고    scopus 로고
    • H-bridge VSC with a t-connected transformer for a 3-phase 4-wire voltage and frequency controller of an isolated asynchronous generator
    • Jan.
    • G. K. Kasal, B. Singh, "H-bridge VSC with a t-connected transformer for a 3-phase 4-wire voltage and frequency controller of an isolated asynchronous generator," Journal of Power Electronics, Vol.9, No.1, pp.43-50, Jan. 2009.
    • (2009) Journal of Power Electronics , vol.9 , Issue.1 , pp. 43-50
    • Kasal, G.K.1    Singh, B.2
  • 6
    • 34547885037 scopus 로고    scopus 로고
    • Control and performance of a transformerless cascade PWM STATCOM with star configuration
    • Jul./Aug.
    • H. Akagi, S. Inoue, T. Yoshii, " Control and performance of a transformerless cascade PWM STATCOM with star configuration," IEEE Transactions on Industry Applications, Vol.43, No.4, pp. 1041-1049, Jul./Aug. 2007.
    • (2007) IEEE Transactions on Industry Applications , vol.43 , Issue.4 , pp. 1041-1049
    • Akagi, H.1    Inoue, S.2    Yoshii, T.3
  • 7
    • 77956893599 scopus 로고    scopus 로고
    • A universal STATCOM with delta-connected cascade multilevel inverter
    • Jun.
    • Fang Z. Peng, Jin Wang, "A universal STATCOM with delta-connected cascade multilevel inverter," IEEE PESC'04, Jun. 2004.
    • (2004) IEEE PESC'04
    • Peng, F.Z.1    Wang, J.2
  • 9
    • 34948890492 scopus 로고    scopus 로고
    • Symmetry compensation using a H-bridge multilevel STATCOM with zero sequence injection
    • Oct.
    • R. E. Betz, T. Summers, and T. Furney. "Symmetry compensation using a H-bridge multilevel STATCOM with zero sequence injection," IEEE Industry Applications Conference, Oct. 2006.
    • (2006) IEEE Industry Applications Conference
    • Betz, R.E.1    Summers, T.2    Furney, T.3
  • 11
    • 72949095141 scopus 로고    scopus 로고
    • New transformerless STATCOM topology for compensating unbalanced medium-voltage loads
    • Sep.
    • H. Mohammadi Pirouz, M. Tavakoli Bina, "New transformerless STATCOM topology for compensating unbalanced medium-voltage loads," EPE'09, Sep. 2009.
    • (2009) EPE'09
    • Mohammadi Pirouz, H.1    Tavakoli Bina, M.2
  • 12
    • 0038015889 scopus 로고    scopus 로고
    • Voltage form factor control and reactive power compensation in a 25-kV electrified railway system using a shunt active filter based on voltage detection
    • Mar./Apr.
    • Pee-Chin Tan, R.E. Morrison, D.G. Holmes, "Voltage form factor control and reactive power compensation in a 25-kV electrified railway system using a shunt active filter based on voltage detection," IEEE Transactions on Industry Applications, Vol.39, No.2, pp. 575-581, Mar./Apr. 2003.
    • (2003) IEEE Transactions on Industry Applications , vol.39 , Issue.2 , pp. 575-581
    • Tan, P.-C.1    Morrison, R.E.2    Holmes, D.G.3
  • 15
    • 85008039066 scopus 로고    scopus 로고
    • Control and experiment of pulsewidthmodulated modular multilevel converters
    • Jul.
    • M. Hagiwara, H. Akagi, "Control and experiment of pulsewidthmodulated modular multilevel converters," IEEE Transactions on Power Electronics, Vol.24, No.7, pp 1737-1746, Jul. 2009.
    • (2009) IEEE Transactions on Power Electronics , vol.24 , Issue.7 , pp. 1737-1746
    • Hagiwara, M.1    Akagi, H.2
  • 16
    • 41549167791 scopus 로고    scopus 로고
    • Averaging technique for the modeling of STATCOM and active filters
    • Mar.
    • M. Tavakoli Bina, A.K.S Bhat, "Averaging technique for the modeling of STATCOM and active filters," IEEE Transactions on Power Electronics, Vol.23, No.2, pp. 723-734, Mar. 2008.
    • (2008) IEEE Transactions on Power Electronics , vol.23 , Issue.2 , pp. 723-734
    • Tavakoli Bina, M.1    Bhat, A.K.S.2
  • 18
    • 41349105309 scopus 로고    scopus 로고
    • Switching characterization of cascaded multilevel-inverter-controlled systems
    • Mar.
    • R. Gupta, A. Ghosh, and A. Joshi, "Switching characterization of cascaded multilevel-inverter-controlled systems," IEEE Transactions on Industrial Electronics, ol.55, no.3, pp. 1047-1058, Mar. 2008.
    • (2008) IEEE Transactions on Industrial Electronics , vol.55 , Issue.3 , pp. 1047-1058
    • Gupta, R.1    Ghosh, A.2    Joshi, A.3
  • 20
    • 0029358962 scopus 로고
    • A three-phase active power filter operating with fixed switching frequency for reactive power and current harmonic compensation
    • Aug.
    • L. A. Moran, J. W. Dixon, and R. R. Wallace, "A three-phase active power filter operating with fixed switching frequency for reactive power and current harmonic compensation," IEEE Trans. Ind. Electron., Vol.42, No.4, pp. 402-408, Aug. 1995.
    • (1995) IEEE Trans. Ind. Electron. , vol.42 , Issue.4 , pp. 402-408
    • Moran, L.A.1    Dixon, J.W.2    Wallace, R.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.