메뉴 건너뛰기




Volumn 37, Issue 6, 2012, Pages 490-496

Pyrocarbon proximal interphalangeal joint arthroplasty: Outcomes of a cohort study

Author keywords

arthritis; proximal interphalangeal joint replacement; Pyrocarbon; range of motion; silicone; subsidence

Indexed keywords

BIOMATERIAL; CARBON; PYROLYTIC CARBON;

EID: 84863228375     PISSN: 17531934     EISSN: 20436289     Source Type: Journal    
DOI: 10.1177/1753193411434053     Document Type: Review
Times cited : (44)

References (25)
  • 1
    • 0141447774 scopus 로고    scopus 로고
    • Die arthroplastik des metakarpophalangealgelenkes mit pyrocarbonimplantaten
    • DOI 10.1007/s00132-003-0519-x
    • Beckenbaugh RD. Arthroplasty of the metacarpophalangeal joint using pyrocarbonate implants. Orthopade. 2003 ; 32: 794-7 (Pubitemid 37214329)
    • (2003) Orthopade , vol.32 , Issue.9 , pp. 794-797
    • Beckenbaugh, R.D.1
  • 2
    • 34250897467 scopus 로고    scopus 로고
    • Resurfacing Arthroplasty Versus Silicone Arthroplasty for Proximal Interphalangeal Joint Osteoarthritis
    • DOI 10.1016/j.jhsa.2007.04.006, PII S0363502307004327
    • Branam BR, Tuttle HG, Stern PJ, Levin L. Resurfacing arthroplasty versus silicone arthroplasty for proximal interphalangeal joint osteoarthritis. J Hand Surg Am. 2007 ; 32: 775-88 (Pubitemid 46991166)
    • (2007) Journal of Hand Surgery , vol.32 , Issue.6 , pp. 775-788
    • Branam, B.R.1    Tuttle, H.G.2    Stern, P.J.3    Levin, L.4
  • 3
    • 33846026399 scopus 로고    scopus 로고
    • Pyrolytic Carbon Proximal Interphalangeal Joint Arthroplasty: Results With Minimum Two-Year Follow-Up Evaluation
    • DOI 10.1016/j.jhsa.2006.10.017, PII S0363502306011439
    • Bravo CJ, Rizzo M, Hormel KB, Beckenbaugh RD. Pyrolytic carbon proximal interphalangeal joint arthroplasty: results with minimum two-year follow-up evaluation. J Hand Surg Am. 2007 ; 32: 1-11 (Pubitemid 46048933)
    • (2007) Journal of Hand Surgery , vol.32 , Issue.1 , pp. 1-11
    • Bravo, C.J.1    Rizzo, M.2    Hormel, K.B.3    Beckenbaugh, R.D.4
  • 4
    • 66549085611 scopus 로고    scopus 로고
    • Outcomes of pyrolytic carbon arthroplasty for the proximal interphalangeal joint
    • Chung KC, Ram AN, Shauver MJ. Outcomes of pyrolytic carbon arthroplasty for the proximal interphalangeal joint. Plast Reconstr Surg. 2009 ; 123: 1521-32
    • (2009) Plast Reconstr Surg , vol.123 , pp. 1521-1532
    • Chung, K.C.1    Ram, A.N.2    Shauver, M.J.3
  • 7
    • 0020826594 scopus 로고
    • The retention mechanics of LTI carbon, carbon-coated aluminum oxide, and uncoated aluminum oxide dental implants
    • Cook SD, Weinstein AM, Klawitter JJ. The retention mechanics of LTI carbon, carbon-coated aluminium oxide, and uncoated aluminium oxide dental implants. J Biomed Mater Res. 1983 ; 17: 873-83 (Pubitemid 14225822)
    • (1983) Journal of Biomedical Materials Research , vol.17 , Issue.5 , pp. 873-883
    • Cook, S.D.1    Weinstein, A.M.2    Klawitter, J.J.3
  • 8
    • 42549141162 scopus 로고    scopus 로고
    • LPM ceramic coated proximal interphalangeal joint arthroplasty
    • Field J. LPM ceramic coated proximal interphalangeal joint arthroplasty. J Hand Surg Eur. 2008 ; 33: 38-44
    • (2008) J Hand Surg Eur , vol.33 , pp. 38-44
    • Field, J.1
  • 9
    • 33750473403 scopus 로고    scopus 로고
    • Problematic bone fixation with pyrocarbon implants in proximal interphalangeal joint replacement: Short-term results
    • DOI 10.1016/j.jhsb.2006.08.004, PII S0266768106004025
    • Herren DB, Schindele S, Goldhahn J, Simmen BR. Problematic bone fixation with pyrocarbon implants in proximal interphalangeal joint replacement: Short-term results. J Hand Surg Br. 2006 ; 31: 643-51 (Pubitemid 44645142)
    • (2006) Journal of Hand Surgery , vol.31 , Issue.6 , pp. 643-651
    • Herren, D.B.1    Schindele, S.2    Goldhahn, J.3    Simmen, B.R.4
  • 10
    • 45849116941 scopus 로고    scopus 로고
    • Cemented Versus Uncemented Surface Replacement Arthroplasty of the Proximal Interphalangeal Joint With a Mean 5-Year Follow-Up
    • DOI 10.1016/j.jhsa.2008.01.030, PII S0363502308000531
    • Johnstone BM, Fitzgerald M, Smith KR, Currie LJ. Cemented versus uncemented surface replacement arthroplasty of the proximal interphalangeal joint with a mean 5-year follow-up. J Hand Surg Am. 2008 ; 33: 726-32 (Pubitemid 351885262)
    • (2008) Journal of Hand Surgery , vol.33 , Issue.5 , pp. 726-732
    • Johnstone, B.R.1    Fitzgerald, M.2    Smith, K.R.3    Currie, L.J.4
  • 11
    • 0035406979 scopus 로고    scopus 로고
    • Proximal interphalangeal joint surface replacement arthroplasty
    • Johnstone B. Proximal interphalangeal joint surface replacement arthroplasty. Hand Surg. 2001 ; 6: 1-11
    • (2001) Hand Surg , vol.6 , pp. 1-11
    • Johnstone, B.1
  • 13
    • 0028895579 scopus 로고
    • Proximal interphalangeal joint silicone replacement arthroplasty: Clinical results using an anterior approach
    • Lin H, Wyrick D, Stern P. Proximal interphalangeal joint silicone replacement arthroplasty: Clinical results using an anterior approach. J Hand Surg Am. 1995 ; 20: 123-32
    • (1995) J Hand Surg Am , vol.20 , pp. 123-132
    • Lin, H.1    Wyrick, D.2    Stern, P.3
  • 14
    • 0030890724 scopus 로고    scopus 로고
    • Development of a surface replacement arthroplasty for proximal interphalangeal joints
    • Linscheid RL, Murray PM, Vidal MA, Beckenbaugh RD. Development of a surface replacement arthroplasty for proximal interphalangeal joints. J Hand Surg Am. 1997 ; 22: 286-98 (Pubitemid 27180611)
    • (1997) Journal of Hand Surgery , vol.22 , Issue.2 , pp. 286-298
    • Linscheid, R.L.1    Murray, P.M.2    Vidal, M.-A.3    Beckenbaugh, R.D.4
  • 15
    • 80052863557 scopus 로고    scopus 로고
    • Failures of the RM finger prosthesis joint replacement system
    • Middleton A, Lakshmipathy R, Irwin LR. Failures of the RM finger prosthesis joint replacement system. J Hand Surg Eur. 2011 ; 36: 599-604
    • (2011) J Hand Surg Eur , vol.36 , pp. 599-604
    • Middleton, A.1    Lakshmipathy, R.2    Irwin, L.R.3
  • 16
    • 84863187633 scopus 로고    scopus 로고
    • Proximal interphalangeal joint arthroplasty with silicone implants (Neuflex) by a lateral approach: A series of 51 case
    • Merle M, Villani F, Lallemand B, Vaienti L. Proximal interphalangeal joint arthroplasty with silicone implants (Neuflex) by a lateral approach: a series of 51 case. J Hand Surg Eur. :
    • J Hand Surg Eur
    • Merle, M.1    Villani, F.2    Lallemand, B.3    Vaienti, L.4
  • 17
    • 0015355985 scopus 로고
    • A new design of finger joint prosthesis for the rheumatoid hand
    • Nicolle FV, Calnan JS. A new design of finger joint prosthesis for the rheumatoid hand. Hand. 1972 ; 4: 135-46
    • (1972) Hand , vol.4 , pp. 135-146
    • Nicolle, F.V.1    Calnan, J.S.2
  • 19
    • 21644436550 scopus 로고    scopus 로고
    • Ersatz von fingermittelgelenken mit pyrocarbonprothesen. Erfahrungswerte nach 1 jahr
    • DOI 10.1007/s00113-004-0891-y
    • Stutz N, Meier R, Krimmer H. Pyrocarbon prosthesis for finger interphalangeal joint replacement. Experience after one year. Unfallchirurg. 2005 ; 108: 365-9 (Pubitemid 40933135)
    • (2005) Unfallchirurg , vol.108 , Issue.5 , pp. 365-369
    • Stutz, N.1    Meier, R.2    Krimmer, H.3
  • 20
    • 0015355468 scopus 로고
    • Flexible implant resection arthroplasty
    • Swanson AB. Flexible implant resection arthroplasty. Hand. 1972 ; 4: 119-34
    • (1972) Hand , vol.4 , pp. 119-134
    • Swanson, A.B.1
  • 21
    • 0014347676 scopus 로고
    • Silicone rubber implants for replacement of arthritis or destroyed joints in the hand
    • Swanson AB. Silicone rubber implants for replacement of arthritis or destroyed joints in the hand. Surg Clin North Am. 1968 ; 48: 1113-27
    • (1968) Surg Clin North Am , vol.48 , pp. 1113-1127
    • Swanson, A.B.1
  • 22
    • 21644452189 scopus 로고    scopus 로고
    • Long-term assessmentof swanson implant arthroplasty in the proximal interphalangeal joint of the hand
    • DOI 10.1016/j.jhsa.2004.03.008, PII S0363502304002692
    • Takigawa S, Meletiou S, Sauerbier M, Cooney WP. Long term assessment of Swanson implant arthroplasty in the PIPJ of the hand. J Hand Surg Am. 2004 ; 29: 785-95 (Pubitemid 39311573)
    • (2004) Journal of Hand Surgery , vol.29 , Issue.5 , pp. 785-795
    • Takigawa, S.1    Meletiou, S.2    Sauerbier, M.3    Cooney, W.P.4
  • 23
    • 33745714179 scopus 로고    scopus 로고
    • Pyrolytic carbon proximal interphalangeal joint resurfacing arthroplasty
    • Tuttle HG, Stern PJ. Pyrolytic carbon proximal interphalangeal joint resurfacing arthroplasty. J Hand Surg Am. 2006 ; 31: 930-9
    • (2006) J Hand Surg Am , vol.31 , pp. 930-939
    • Tuttle, H.G.1    Stern, P.J.2
  • 24
    • 0034120816 scopus 로고    scopus 로고
    • Kinematics of the proximal interphalangeal joint of the finger after surface replacement
    • DOI 10.1067/jhsu.2000.jhsu25a0305
    • Uchiyama S, Cooney WP, Linscheid RL, Niebur G, An KN. Kinematics of the proximal interphalangeal joint of the finger after surface replacement. J Hand Surg Am. 2000 ; 25: 305-12 (Pubitemid 30165595)
    • (2000) Journal of Hand Surgery , vol.25 , Issue.2 , pp. 305-312
    • Uchiyama, S.1    Cooney III, W.P.2    Linscheid, R.L.3    Niebur, G.4    An, K.-N.5
  • 25
    • 72449205574 scopus 로고    scopus 로고
    • Outcomes of proximal interphalangeal joint pyrocarbon implants
    • Wijk U, Wollmark M, Kopylov P, Tagil M. Outcomes of proximal interphalangeal joint pyrocarbon implants. J Hand Surg Am. 2010 ; 35: 38-43
    • (2010) J Hand Surg Am , vol.35 , pp. 38-43
    • Wijk, U.1    Wollmark, M.2    Kopylov, P.3    Tagil, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.