-
1
-
-
0028229154
-
Flexible implant resection arthroplasty of the proximal interphalangeal joint in patients with systemic inflammatory arthritis
-
Adamson G.J., Gellman H., Brumfield Jr. R.H., Kuschner S.H., and Lawler J.W. Flexible implant resection arthroplasty of the proximal interphalangeal joint in patients with systemic inflammatory arthritis. The Journal Hand Surgery 19A (1994) 378-384
-
(1994)
The Journal Hand Surgery
, vol.19 A
, pp. 378-384
-
-
Adamson, G.J.1
Gellman, H.2
Brumfield Jr., R.H.3
Kuschner, S.H.4
Lawler, J.W.5
-
2
-
-
0036933326
-
Isoelastic femoral component in primary cementless total hip arthroplasty
-
Ali M.S., and Kumar A. Isoelastic femoral component in primary cementless total hip arthroplasty. International Orthopedics 26 (2002) 243-246
-
(2002)
International Orthopedics
, vol.26
, pp. 243-246
-
-
Ali, M.S.1
Kumar, A.2
-
3
-
-
0030800799
-
Swanson proximal interphalangeal joint arthroplasty in patients with rheumatoid arthritis
-
Ashworth C.R., Hansraj K.K., Todd A.O., Dukhram K.M., Ebramzadeh E., Boucree J.B., and Hansraj M.S. Swanson proximal interphalangeal joint arthroplasty in patients with rheumatoid arthritis. Clinical Orthopaedics and Related Research 342 (1997) 34-37
-
(1997)
Clinical Orthopaedics and Related Research
, vol.342
, pp. 34-37
-
-
Ashworth, C.R.1
Hansraj, K.K.2
Todd, A.O.3
Dukhram, K.M.4
Ebramzadeh, E.5
Boucree, J.B.6
Hansraj, M.S.7
-
4
-
-
0026607965
-
Intermittent micromotion inhibits bone ingrowth of Titanium implants in rabbits
-
Aspenberg P., Goodman S., Toksvig-Larsen S., Ryd L., and Albrektsson T. Intermittent micromotion inhibits bone ingrowth of Titanium implants in rabbits. Acta Orthopedica Scandinavica 63 (1992) 141-145
-
(1992)
Acta Orthopedica Scandinavica
, vol.63
, pp. 141-145
-
-
Aspenberg, P.1
Goodman, S.2
Toksvig-Larsen, S.3
Ryd, L.4
Albrektsson, T.5
-
5
-
-
0020513847
-
Preliminary experience with a noncemented nonconstrained total joint arthroplasty for the metacarpophalangeal joints
-
Beckenbaugh R.D. Preliminary experience with a noncemented nonconstrained total joint arthroplasty for the metacarpophalangeal joints. Orthopedics 6 (1983) 962-965
-
(1983)
Orthopedics
, vol.6
, pp. 962-965
-
-
Beckenbaugh, R.D.1
-
6
-
-
0020823258
-
Osseointegration and its experimental background
-
Branemark P.I. Osseointegration and its experimental background. Journal of Prosthetics Dentology 50 (1983) 399-410
-
(1983)
Journal of Prosthetics Dentology
, vol.50
, pp. 399-410
-
-
Branemark, P.I.1
-
7
-
-
0023786140
-
A distally based dorsal triangular tendinous flap for direct access to the proximal interphalangeal joint
-
Chamay A. A distally based dorsal triangular tendinous flap for direct access to the proximal interphalangeal joint. Annales Chirurgie de la Main 7 (1988) 179-183
-
(1988)
Annales Chirurgie de la Main
, vol.7
, pp. 179-183
-
-
Chamay, A.1
-
8
-
-
0033008636
-
Long-term follow-up of pyrocarbon metacarpophalangeal implants
-
Cook S.D., Beckenbaugh R.D., Redondo J., Popich L.S., Klawitter J.J., and Linscheid R.L. Long-term follow-up of pyrocarbon metacarpophalangeal implants. The Journal of Bone and Joint Surgery 81A (1999) 635-648
-
(1999)
The Journal of Bone and Joint Surgery
, vol.81 A
, pp. 635-648
-
-
Cook, S.D.1
Beckenbaugh, R.D.2
Redondo, J.3
Popich, L.S.4
Klawitter, J.J.5
Linscheid, R.L.6
-
11
-
-
0028081273
-
On the durability of pyrocarbon in vivo
-
Haubold A.D. On the durability of pyrocarbon in vivo. Medical Progression in Technology 20 (1994) 201-208
-
(1994)
Medical Progression in Technology
, vol.20
, pp. 201-208
-
-
Haubold, A.D.1
-
12
-
-
33750430102
-
-
Heers, G., Borisch, N., (2005). Erste Ergebnisse nach Implantation einer Pyrocarbonprothese bei Mittelgelenkarthrose. Paper presented at DAH Congress, Vienna.
-
-
-
-
13
-
-
0033973210
-
Palmar approach in flexible implant arthroplasty of the proximal interphalangeal joint
-
Herren D.B., and Simmen B.R. Palmar approach in flexible implant arthroplasty of the proximal interphalangeal joint. Clinical Orthopadics and Related Research 371 (2000) 131-135
-
(2000)
Clinical Orthopadics and Related Research
, vol.371
, pp. 131-135
-
-
Herren, D.B.1
Simmen, B.R.2
-
14
-
-
0024461204
-
Adaptive bone remodeling and biomechanical design considerations for noncemented total hip arthroplasty
-
Huiskes R., Weinans H., and Dalstra M. Adaptive bone remodeling and biomechanical design considerations for noncemented total hip arthroplasty. Orthopaedics 12 (1989) 1255-1267
-
(1989)
Orthopaedics
, vol.12
, pp. 1255-1267
-
-
Huiskes, R.1
Weinans, H.2
Dalstra, M.3
-
15
-
-
0029040293
-
Long-term results of proximal interphalangeal joint resection arthroplasties with a silicone implant
-
Iselin F., and Conti E. Long-term results of proximal interphalangeal joint resection arthroplasties with a silicone implant. The Journal of Hand Surgery 20A (1995) S95-S97
-
(1995)
The Journal of Hand Surgery
, vol.20 A
-
-
Iselin, F.1
Conti, E.2
-
16
-
-
0028895579
-
Proximal interphalangeal joint silicone replacement arthroplasty: clinical results using an anterior approach
-
Lin H.H., Wyrick J.D., and Stern P.J. Proximal interphalangeal joint silicone replacement arthroplasty: clinical results using an anterior approach. The Journal Hand Surgery 20A (1995) 123-132
-
(1995)
The Journal Hand Surgery
, vol.20 A
, pp. 123-132
-
-
Lin, H.H.1
Wyrick, J.D.2
Stern, P.J.3
-
19
-
-
0032736405
-
Arthroplasty of the proximal interphalangeal joint using the Sutter implant for traumatic joint destruction
-
Mathoulin C., and Gilbert A. Arthroplasty of the proximal interphalangeal joint using the Sutter implant for traumatic joint destruction. The Journal of Hand Surgery 24 (1999) 565-569
-
(1999)
The Journal of Hand Surgery
, vol.24
, pp. 565-569
-
-
Mathoulin, C.1
Gilbert, A.2
-
20
-
-
33750440926
-
-
Meier, R., Schulz, M., Krimmer, H., Lanz, U., (2005). Fruehe Ergebnisse des Fingermittelgelenkersatzes mit einer ungekoppelten Pyrocarbonprothese bei idiopathischer und posttraumatischer Arthrose. Paper presented at: DAH Congress, Vienna.
-
-
-
-
21
-
-
0033777009
-
DIGITOS-prosthesis for the proximal interphalangeal joint. A 2-year follow-up
-
Mentzel M., Hoss H., Ebinger T., Halder A., Kinzl L., and Wachter N.J. DIGITOS-prosthesis for the proximal interphalangeal joint. A 2-year follow-up. Handchirurgie Mikrochirurgie und Plastische Chirurgie, 32 (2000) 347-352
-
(2000)
Handchirurgie Mikrochirurgie und Plastische Chirurgie
, vol.32
, pp. 347-352
-
-
Mentzel, M.1
Hoss, H.2
Ebinger, T.3
Halder, A.4
Kinzl, L.5
Wachter, N.J.6
-
22
-
-
20444490885
-
Pyrocarbon PIP arthroplasty for post trauma painful joints
-
Munshy P., Trail I.A., Stanley J.K., Rebelo N., Freire A., and Mota da Costa J. Pyrocarbon PIP arthroplasty for post trauma painful joints. The Journal of Hand Surgery 28A Suppl 1 (2003) 44
-
(2003)
The Journal of Hand Surgery
, vol.28 A
, Issue.SUPPL. 1
, pp. 44
-
-
Munshy, P.1
Trail, I.A.2
Stanley, J.K.3
Rebelo, N.4
Freire, A.5
Mota da Costa, J.6
-
23
-
-
0029129207
-
Bone loss from the proximal femur after arthroplasty with an isoelastic femoral stem. BMD measurements in 25 patients after 9 years
-
Niinimaki T., and Jalovaara P. Bone loss from the proximal femur after arthroplasty with an isoelastic femoral stem. BMD measurements in 25 patients after 9 years. Acta Orthopedica Scandinavica, 66 (1995) 347-351
-
(1995)
Acta Orthopedica Scandinavica
, vol.66
, pp. 347-351
-
-
Niinimaki, T.1
Jalovaara, P.2
-
24
-
-
51249168584
-
Der palmare Zugang zur Arthroplastik des proximalen Interphalangeal-Finger-Gelenkes
-
Simmen B.R. Der palmare Zugang zur Arthroplastik des proximalen Interphalangeal-Finger-Gelenkes. Operative techniken Orthopaedie und Traumatologie 5 (1993) 112-123
-
(1993)
Operative techniken Orthopaedie und Traumatologie
, vol.5
, pp. 112-123
-
-
Simmen, B.R.1
-
25
-
-
21644436550
-
Pyrocarbon prosthesis for proximal interphalangeal joint replacement
-
Stutz N., and Meier R. Pyrocarbon prosthesis for proximal interphalangeal joint replacement. Experience after one year. Der Unfallchirurgie 108 (2005) 365-369
-
(2005)
Experience after one year. Der Unfallchirurgie
, vol.108
, pp. 365-369
-
-
Stutz, N.1
Meier, R.2
-
26
-
-
0015840628
-
Implant resection arthroplasty of the proximal interphalangeal joint
-
Swanson A.B. Implant resection arthroplasty of the proximal interphalangeal joint. Orthopedic Clinics of North America 4 (1973) 1007-1029
-
(1973)
Orthopedic Clinics of North America
, vol.4
, pp. 1007-1029
-
-
Swanson, A.B.1
-
28
-
-
21644452189
-
Long-term assessment of Swanson implant arthroplasty in the proximal interphalangeal joint of the hand
-
Takigawa S., Meletiou S., Sauerbier M., and Cooney W.P. Long-term assessment of Swanson implant arthroplasty in the proximal interphalangeal joint of the hand. The Journal of Hand Surgery 29A (2004) 785-795
-
(2004)
The Journal of Hand Surgery
, vol.29 A
, pp. 785-795
-
-
Takigawa, S.1
Meletiou, S.2
Sauerbier, M.3
Cooney, W.P.4
-
29
-
-
0034120816
-
Kinematics of the proximal interphalangeal joint of the finger after surface replacement
-
Uchiyama S., Cooney III W.P., Linscheid R.L., Niebur G., and An K.N. Kinematics of the proximal interphalangeal joint of the finger after surface replacement. The Journal of Hand Surgery 25A (2000) 305-312
-
(2000)
The Journal of Hand Surgery
, vol.25 A
, pp. 305-312
-
-
Uchiyama, S.1
Cooney III, W.P.2
Linscheid, R.L.3
Niebur, G.4
An, K.N.5
|